1 / 12

Three-State Air Quality Study (3SAQS) Three-State Data Warehouse (3SDW)

Three-State Air Quality Study (3SAQS) Three-State Data Warehouse (3SDW). 3SAQS Revised 2011 Modeling Protocol Reflecting Reviewer Comments University of North Carolina (UNC-IE) Cooperative Institute for Research in the Atmosphere (CIRA) ENVIRON International Corporation (ENVIRON )

perry
Download Presentation

Three-State Air Quality Study (3SAQS) Three-State Data Warehouse (3SDW)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Three-State Air Quality Study (3SAQS)Three-State Data Warehouse (3SDW) 3SAQS Revised 2011 Modeling Protocol Reflecting Reviewer Comments University of North Carolina (UNC-IE) Cooperative Institute for Research in the Atmosphere (CIRA) ENVIRON International Corporation (ENVIRON) July 28, 2014

  2. Four set of Comments provided on the draft 3SAQS 2011 Modeling Protocol (April 2014) • Responders: • U.S. EPA Region 8 • Gail Tonnesen, Rebecca Matichuk and Robin Coursen • Mike Barna, NPS • Tammy Thomson, CSU/NPS • Brian Bohlmann, Wyoming DEQ • Responses discussed on June 19, 2008 Conference Call • Response-to-Comments document dated July 22, 2014 • Revised Draft 2011 Modeling Protocol (July 2014)

  3. Revised 3SAQS Draft 2011Modeling Protocol • Main updates were: • Add description of 3SAQS 2015 Work • More details on MPE • Explanations • Snow cover albedo • MOZART vs. GEOS-Chem • MEGAN vs. BEIS • PMDETAIL vs. SMARTFIRE • Clarifications • Typos • Remove citations from footnotes

  4. Changes in Revised 2011 Modeling Protocol • 1.0 Introduction • Numerous language changes • Make clearer that 2011 platform not just for O&G • New Section 1.5.2 and Table 1.2 • State Rulemakings that affect O&G Emissions • 2.0 Model Selection • Made clear that CMAQ is being applied and part of MPE and FY modeling (3SAQS 2015 SOW) • 3.0 Episode Selection (None)

  5. Changes in Revised 2011 Modeling Protocol • 4.0 Domain Selection • Added 4 km plot  • 5.0 WRF Modeling • Winter O3 in 2015 SOW

  6. Changes in Revised 2011 Modeling Protocol • 6.0 Emissions • Added justification for: • MEGAN vs. BEIS (Biogenics) • PMDETAIL vs. SMARTFIRE (Fires) • Questions on SMOKE processing streams and requests for separating specific source categories • Updated Table 6-1 and text to be clearer which source categories are being processed separately • Response-to-Comments responses to request for each source category

  7. Changes in Revised 2011 Modeling Protocol • 6.0 Emissions • Clarified Figure6-1 3SAQS 4 km Domain

  8. Changes in Revised 2011 Modeling Protocol • 6.0 Emissions • Separated discussion of development of 2011 and 2020 O&G emissions like was done for other source categories • Clarified 2020 O&G projection assumptions: • State-provided – activity growth/decline and no controls analysis • Survey-based – activity growth/decline and controls analysis including no turnover assumption when decline

  9. Changes in Revised 2011 Modeling Protocol • 7.0 Photochemical Modeling • Will configure CAMx/CMAQ and WRF for winter ozone event modeling in 3SAQS 2015 SOW • Will include use of high snow cover albedo instead of average value that is used for regional modeling • Included new Table 7-2 listing CMAQ model configuration

  10. Changes in Revised 2011 Modeling Protocol • 8.0 Model Performance Evaluation • Ozone performance metrics use 60 ppb threshold • Commit to evaluation for O3/PM precursors • No change, already in Protocol • Evaluation against NH3 measurements • Added description of AMON network and commit to use data in evaluation

  11. Changes in Revised 2011 Modeling Protocol • 8.0 Model Performance Evaluation • Vertical Ozone Comparisons • Protocol already mentions evaluation against ~50 ozonesonde released at Boulder, CO in 2011 • Researching questions regarding 2011 UGEWOS ozone soundings • Snow Cover and Albedo • Will address in 3SAQS 2015 SOW when analyzing winter ozone events • Precipitation and Cloud Cover • Evaluation of WRF for monthly PRISM precipitation completed • Questions regarding reliability of PRISM for summer convection • Future plans for use of daily PRISM data analysis fields • Will examine cloud cover for winter ozone events

  12. Changes in Revised 2011 Modeling Protocol • 8.0 Model Performance Evaluation • Diagnostic Model Outputs • Diagnostic sensitivity tests addressed in 3SAQS 2015 SOW with input from 3SAQS Technical Committee • Will include BC sensitivity if alternative BCM output available

More Related