1 / 21

Using the Absorbing Aerosol Index (AAI) to monitor GOME-2 instrument degradation

Using the Absorbing Aerosol Index (AAI) to monitor GOME-2 instrument degradation. L.G. Tilstra, O.N.E. Tuinder, P. Stammes Royal Netherlands Meteorological Institute (KNMI). Expert Meeting on GOME-2 instrument degradation, KNMI, De Bilt, 04-03-2010. Outline Short introduction of the AAI

phuc
Download Presentation

Using the Absorbing Aerosol Index (AAI) to monitor GOME-2 instrument degradation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Using the Absorbing Aerosol Index (AAI) to monitor GOME-2 instrument degradation L.G. Tilstra, O.N.E. Tuinder, P. Stammes Royal Netherlands Meteorological Institute (KNMI) Expert Meeting on GOME-2 instrument degradation, KNMI, De Bilt, 04-03-2010

  2. Outline • Short introduction of the AAI • GOME-1 instrument degradation • GOME-2 instrument degradation • SCIAMACHY instrument degradation • Overview of results / Conclusions Expert Meeting on GOME-2 instrument degradation, KNMI, De Bilt, 04-03-2010

  3. 1 / Introduction: Absorbing Aerosol Index (AAI) and the residue – The AAI represents the scene colour in the UV – • Definition of the residue: where the surface albedo A for the simulations is such that: (A is assumed to be wavelength independent: A340 = A380) no clouds, no aerosols : r = 0 clouds, no absorbing aerosols : r < 0 absorbing aerosols : r > 0 B. Definition of the AAI: AAI = residue > 0 (and the AAI is not defined where residue < 0) Expert Meeting on GOME-2 instrument degradation, KNMI, De Bilt, 04-03-2010

  4. 2 / Instrument degradation: GOME-1 The global mean residue (GMR), the mean of all residues on a day between 60°N and 60°S, is about constant, showing only a very mild seasonal variation. dashed green line: 12-MAR-1996, end of the GOME-1 commissioning phase 22 June 2003: loss of global coverage The seasonal cycle is caused primarily by variation in aerosol presence First signs of the effects of instrument degradation after ~4 years after launch. Expert Meeting on GOME-2 instrument degradation, KNMI, De Bilt, 04-03-2010

  5. GMR for each individual GOME-1 scan-mirror position (East, Nadir, West): dashed green line: 12-MAR-1996, end of the GOME-1 commissioning phase GOME-1 commissioning phase: reduced footprint size, symmetry around exact nadir broken Krijger et al., ESA SP-636, 2007: Clearly, GOME-1 is showing a scan-angle dependent instrument degradation. Scan-angle dependency is modest in the first 4 years, but starts up almost immediately after launch. Expert Meeting on GOME-2 instrument degradation, KNMI, De Bilt, 04-03-2010

  6. GMR per scan-mirror position relative to mean over scan-mirror positions: “Delta[east/nadir/west]” = GMR[east/nadir/west] – GMR[all] • Scan-angle dependent degradation starts immediately after launch • Maximum east/west bias: ~5.5 index points reached after ~6 years • East/west bias changed with ~0.8 index points over the first 3 years • Periodic behaviour: geometry effect due to changing solar position Scan-angle dependent degradation + small seasonal cycle due to geometry. Expert Meeting on GOME-2 instrument degradation, KNMI, De Bilt, 04-03-2010

  7. 3 / Instrument degradation: GOME-2 GOME-1 experience: the global mean of all residues on a day between 60°N and 60°S is about constant, showing only a very mild seasonal variation. black : GOME-2 green : GOME-2 (GOME-1 swath) red : GOME-1 (parameterisation) Similar seasonal cycle as GOME-1. First signs of the effects of instrument degradation. Expert Meeting on GOME-2 instrument degradation, KNMI, De Bilt, 04-03-2010

  8. Global mean residue per scanner mirror position versus time (1): [ forward scan pixels only ] • Global coverage is now a factor 24 lower, yet there are enough data points for a reliable daily “global mean residue” Downward trend is for sure caused by instrument degradation; easternmost scan mirror positions are apparently affected in a different manner than the rest. Expert Meeting on GOME-2 instrument degradation, KNMI, De Bilt, 04-03-2010

  9. Global mean residue per scanner mirror position versus time (2): [ indicated scan pixels only ] • Global mean residue at the swath edges is higher than in the middle of the swath • Global mean residue of eastern side of the swath shows a very deviating & varying behaviour • Growing east/west bias: ~1.4 index points after ~3 years For GOME-1 the viewing angles at the swath edges are much smaller. As a result, the global mean residue at the swath edges roughly equals that of the middle of the swath.    Expert Meeting on GOME-2 instrument degradation, KNMI, De Bilt, 04-03-2010

  10. Global mean residue per scanner mirror position versus time (3): [ GOME-1 swath ] • Growing east/west bias in this case: ~1.0 index points over a period of ~3 years • GOME-1: east/west bias grew with ~0.8 index points over the first 3 years after launch So, for the GOME-1 part of the GOME-2 swath the scan-angle dependent component of the degradation is only a bit higher than that of GOME-1 in the first 3 years after launch. Expert Meeting on GOME-2 instrument degradation, KNMI, De Bilt, 04-03-2010

  11. GMR per scan-mirror position relative to mean over scan-mirror positions: “Delta_Mean[IndexInScan]” = GMR[IndexInScan] – GMR[all] [ indicated scan pixels only ] • Western and nadir scan-mirror positions degrade in more or less the same manner and rate • Eastern mirror positions degrade very differently Expert Meeting on GOME-2 instrument degradation, KNMI, De Bilt, 04-03-2010

  12. 4 / Instrument degradation: SCIAMACHY Different behaviour: • Increase in global mean residue instead of an initial decrease (as was the case for GOME-1) • Clearly also scan-angle dependent degradation after a couple of years • Roughly 5 index points higher after 8 years in space • No “maximum” reached yet (GOME-1: after ~6 years) First signs of the effects of instrument degradation after ~1 year after launch. Expert Meeting on GOME-2 instrument degradation, KNMI, De Bilt, 04-03-2010

  13. GMR per scan-mirror position relative to mean over scan-mirror positions: • East/west bias of nearly 3 index points after ~8 years • Slower rate of instrument degradation than GOME-1/2 • Relatively late startup of scan-angle dependency compared to GOME-1 and GOME-2 SCIAMACHY instrument degradation seems to be progressing at a slower pace. Expert Meeting on GOME-2 instrument degradation, KNMI, De Bilt, 04-03-2010

  14. 5 / Overview of results / Conclusions GOME-1: scan-angle dependent degradation Slow degradation started directly after launch. Extreme degradation after ~4 years; East/west bias ~5.5 index points after ~6 years. Average degradation after 3 years : ~–0.0 pts East/west bias after 3 years : ~0.8 pts SCIAMACHY: scan-angle dependent degradation Degradation started 1 year after launch (an increase instead of a decrease). No max. yet, east/west bias ~3 index points after 8 years. Average degradation after 3 years : ~+0.7 pts East/west bias after 3 years : ~0.3 index points GOME-2: scan-angle dependent degradation Degradation started directly after launch. If comparable to GOME-1, then there should be extreme reflectance degradation in 1-2 years. Average degradation after 3 years : ~–0.8 pts East/west bias after 3 years : ~1.4 pts (1.0 pts G1 swath) Expert Meeting on GOME-2 instrument degradation, KNMI, De Bilt, 04-03-2010

  15. Extra slides (R) Expert Meeting on GOME-2 instrument degradation, KNMI, De Bilt, 04-03-2010

  16. R1: Global mean per scan-mirror position, shifted to zero for t=0: [ indicated scan pixels only ] • growing east/west bias: ~1.4 index points in ~3 years Downward trend is for sure caused by instrument degradation; easternmost scan mirror positions are apparently affected in a different manner than the rest. Expert Meeting on GOME-2 instrument degradation, KNMI, De Bilt, 04-03-2010

  17. R2: Typical global aerosol distribution: The “Global Dust Belt”: Desert Dust Aerosols (DDA) (dust storms, all year) Biomass Burning Aerosols (BBA) (dry season, anthropogenic) AAI from other UV satellite instruments: TOMS, GOME-1, SCIAMACHY, OMI. Combined with GOME-2 there are more than three decades (1978–2009) of AAI data available for studies of trends in desert dust and biomass burning aerosol. Expert Meeting on GOME-2 instrument degradation, KNMI, De Bilt, 04-03-2010

  18. R3: The “Global Dust Belt” Expert Meeting on GOME-2 instrument degradation, KNMI, De Bilt, 04-03-2010

  19. R4: General impression of the global aerosol distribution reported by GOME-2: east/west bias is gone since PPF 4.0 Features at the eastern side of the swath at high latitudes are under investigation. Expert Meeting on GOME-2 instrument degradation, KNMI, De Bilt, 04-03-2010

  20. R5: Global mean versus scanner mirror position: [also including backscan (BS) pixels] FW BS • global mean residue is roughly symmetrical w.r.t. the exact nadir position [ok] • growing east/west bias • behaviour of backscan pixels is not fully understood yet In conclusion, the GOME-2 AAI has shown to be reasonably stable over the last two years, but the need for a degradation correction is growing. Expert Meeting on GOME-2 instrument degradation, KNMI, De Bilt, 04-03-2010

  21. R6: Kasatochi volcanic eruption on 7 August 2008: (Kasatochi, Aleutian Islands, 52.17°N, 175.51°W; summit 314 m) The ash plume resulting from the Kasatochi eruption was well captured by the GOME-2 AAI Expert Meeting on GOME-2 instrument degradation, KNMI, De Bilt, 04-03-2010