1 / 43

CCIR 322-2 Atmospheric Noise

CCIR 322-2 Atmospheric Noise. Why do this?. Understand the evolution atmospheric noise measurements Determine what are appropriate values to use from the CCIR documentation Compare CCIR data alternative noise data Define the noise environment so mitigation techniques may be explored.

pilialoha
Download Presentation

CCIR 322-2 Atmospheric Noise

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CCIR 322-2Atmospheric Noise

  2. Why do this? • Understand the evolution atmospheric noise measurements • Determine what are appropriate values to use from the CCIR documentation • Compare CCIR data alternative noise data • Define the noise environment so mitigation techniques may be explored

  3. What is CCIR 322-2? • Reported background atmospheric noise levels • Evolved into ITU P372-7 • Included man-made and galactic noise • Removed technical background • Used the ARN-2 Radio Noise Recorder • 16 Stations around the globe • Average noise power at each of eight frequencies for fifteen minutes each hour • 13 kHz, 11kHz, 250kHz, 500kHz, 2.5MHz, 5MHz, 10MHz, and 20MHz • 1957-1961 (4 years) → 8640 15-minute measurements → 99.98% • Tracked filtered noise envelope not instantaneous noise • Took high speed data to obtain APDs

  4. What is CCIR 322-2? (cont) • Sectioned the year into seasons and time blocks • Four 90-day seasons • Six 4-hour time blocks • Tracked external antenna noise factor, Fa • Power received through a loss-free antenna Fa = 10*log10(Pn/KToB) • Lists the median value hourly value for each time block, Fam, at 1 MHz • Lists the upper decile (90%) level Du • Calculate noise E-field from Fa, BW, frequency • Use normal or log-normal statistics and graphs to adjust values

  5. CCIR Stations

  6. Fam for Summer 20-24h

  7. Three Step Process for CCIR Data

  8. Computing E-field from CCIR

  9. Computing E-field from CCIR (cont)

  10. Computing CCIR Data +14 dB +16 dB <Emedian> = 50 dB uV/m <E95%> = 64 dB uV/m E95% |99%= 80 dB uV/m

  11. Adjustment to Enoise at 95% Time Availability for Service Probability

  12. RMS Envelope vs Inst. Envelope • Failure mode of receiver sometimes dictates using Inst. Envelope values over RMS Envelope values (eg FSK). • Needed a way to measure the “impulsiveness” of the noise. • Came up with using Vd • Vd = 20 * log10( Arms / Aavg) • Vd for Rayleigh (Gaussian > 0) is 1.05 • Larger Vd mean the more impulsive or less Gaussian the noise

  13. CCIR APD Experimental Setup Instantaneous Noise, Vn • Thanks to Bob Matherson and CCIR IF Inst. Noise Voltage, VIF Atm Noise Instantaneous Noise Envelope, A RMS Noise Envelope, Arms Average Noise Envelope, Aavg

  14. VIF Voltage and Noise Envelope Voltages

  15. Envelope RMS Voltage (Arms) & Instantaneous Envelope Voltage (A) • Arms is 3dB above rms instantaneous noise voltage VIFrms • APD • Amplitude Probability Distribution or A Posteriori Distribution • Exceedance probability P[A > Arms + D=A0] • Parameterized by Vd - Voltage deviation • Plotted on Rayleigh Probability Paper 0 Rayleigh Vd = 1.05 More Impulsive

  16. CCIR FSK Example Results Time availability as a function of service probability Geneva, Switzerland Summer season: 2000-2400 h Frequency: 50 kHz Bandwidth: 100 Hz Binary errors: 0.05% Montgomery [1954] Model

  17. CCIR Limitation (1983 §1) • "The estimates for atmospheric noise levels given in the Report are for the average background noise level due to lightning in the absence of other signals, whether intentionally or unintentionally radiated. In addition, the noise due to local thunderstorms has not been included. In some areas of the world, the noise from local thunderstorms can be important for a significant percentage of the time."

  18. CCIR Limitations (cont) • “Atmospheric radio noise is characterized by large, rapid fluctuations, but if the noise power is averaged over a period of several minutes, the average values are found to be nearly constant during a given hour variations rarely exceeding ±2dB except near sunrise or sunset, or when there are local thunderstorms.”

  19. CCIR Questions • What should we specify as a service probability 95%? • What is an appropriate level of availability? • How do the values change when we are near lightning?

  20. Electric/Magnetic Field Data (cont) dB(V/m/Hz) Preta 1984

  21. Obtaining E-field from Lightning Return Stroke Data

  22. Comparing E-fields and Distance • Lightning E-field data varies with 1/D • E2-E1 = 20*log10(D1/D2) = 20*log10(50km/D2) • For 100 kHz, an Enoise of 80 dB uV/m is equivalent to being 8.7 km from continuous repetitive lightning return strokes! • Can do this for all levels of % Time availability for any Service Probability

  23. Conclusion from CCIR Data • Calculate Noise Level • Specify % Time and Confidence • Alternatively, as a distance to a lightning return stroke. I.e. define this as a ATC constraint

  24. Summary • Reviewed CCIR-322 and current lightning research and found good correlation between both data sets. • Need to set both a not-to-exceed level and a confidence to make a reasonable estimate of noise level or can define a distance to a lightning return stroke. e.g. define this as a ATC constraint. • Need to use nonlinear processing to increase SNR. • Have pieces for a time-domain model.

  25. Backup Slides

  26. Processing Gain

  27. Mitigation Techniques • Clipping or Blanking based on Vd • Spaulding/Middleton • Modestino/Enge • Using the Loran antenna as a lightning detector/locator • Low frequency signals propagate faster than higher frequency signals • Magnetic antenna / magnetometer

  28. Spaulding/Middleton (Parametric) • Divide all noise into three canonical forms • Class A (3 parameters) • (duration of noise)(receiver bandwidth) >> 1 • Negligible transients are produced in linear front-end of receiver. • Steady state series of waves produced. • Class B (3 or 6 parameters) • (duration of noise)(receiver bandwidth) << 1 • All transients are produced in linear front-end of receiver. • Overlapping impulse response. • Class C (8 parameters) • (duration of noise)(receiver bandwidth) << 1 • Additive mixture of Class A and B • Use optimal adaptive non-linear filtering for improvement • Use suboptimal non-linear filtering (e.g. hole punch, hard limiter, etc) Spaulding 1986

  29. Spaulding 1986

  30. ~30dB Improvement! ~30dB Spaulding 1986

  31. Summary • Reviewed some signal processing with non-Gaussian Noise • Much to be learned from the already published work regarding the processing of signals in non-Gaussian noise. • Large gains may be made by utilizing adaptive filters and even sub-optimal ones. • Currently trying to fit CCIR APD to 3-Parameter Class B Model to various Vd in order to bound gains

  32. Negative Leader CG Lightning

  33. National Lightning Detection Network • Privately run • Real-Time data collection • Mostly detection and high level data • Some waveform data • Can use newer analytical field models

  34. Sample Data … for another hour and a half !

  35. Lightning Characteristics

  36. Electric/Magnetic Field Data Intracloud Stepped Leader Return Pulse Intracloud Krider 1975 Weidman 1981

  37. Lightning Spectrum Return Positive Intracloud Stepped Leader Negative Intracloud

  38. Comparing E-fields and Distance • Lightning E-field data varies with 1/D • 20*log10(E2/E1) = 20*log10(D1/D2) = 20*log10(50km/D2) • For 100 kHz, an Enoise of 96 dB uV/m is equivalent to Lightning Return Stroke at 1.4 km! • Can do this for all levels of % Time availability for any Service Probability

  39. CCIR Median Data for 99% Level

  40. Time Domain Model • Thunder days for this hemisphere • ~60 in N. Am / ~100-200 Central/South Am • Lightning stroke data from NLDN • Electric/magnetic field models from Uman • CCIR alternative based on APD • Gaussian portion - background • Impulsive portion – strikes

  41. Envelope APD 0

  42. 3 Parameter Fit

More Related