1 / 17

iNode Product Overview

iNode Product Overview. iNodes: A Closer Look. Totally cable-free, easy to install Completely integrated and self-powered Engineered specifically for O&G Sample often, transmit hourly or daily, alarms Field configurable “Distributed intelligence” Class I DIV I. iNode Quick Overview.

quilla
Download Presentation

iNode Product Overview

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. iNode Product Overview

  2. iNodes: A Closer Look • Totally cable-free, easy to install • Completely integrated and self-powered • Engineered specifically for O&G • Sample often, transmit hourly or daily, alarms • Field configurable • “Distributed intelligence” • Class I DIV I Confidential

  3. iNode Quick Overview Intrinsically Safe! Confidential

  4. Product Family EFM Gas Flow CCU OR Modbus Gateway TLM Tank Level WPM Pressure WDS Totalizer Confidential

  5. WPM - Wireless Pressure Monitor • Casing & tubing pressures, injections pumps, compressor suction and discharge, etc • Pressure ranges are 75, 500, 1500, 3600 and 6000psig • Accuracy +/- 1.0% FS over temperature • Temperature RTD optional • Alarms: High/low pressure and temperature Confidential

  6. EFM – Electronic Flow Meter • Monitors natural gas flow per API/AGA specs • Multi-variable Honeywell transducer • Transducer Accuracy: 0.25%FS DP,SP standard. 0.075% available. • Data available: • Instantaneous SP, DP, Temp and flow rate • Last Hours Average SP, DP and Temp, & Volume • Last Day Average SP, DP and Temp, & Volume • 35+ days of Daily and Hourly Records • 400+ Events • Supports Gross and Detail Calculations • Alarms: High/Low flow, SP, DP and temperature Confidential

  7. TLM3 – Tank Level Monitor Overview: Rod and float based, multi-phase tank level measurement device with an accuracy equal to or better than the Pumper (<+/-0.5”) Confidential

  8. WDS (Wireless Totalizer) • Monitors pulse inputs from industry standard turbine meters (i.e. Nuflo) • Pulse Frequency 10Hz – 2KHz • Intrinsically Safe when used with supplied Honeywell IS magnetic pick-up • Calculates rates and volumes based on user programmed meter coefficient • Alarms: High/Low flow rate Confidential

  9. CFR – Compact Flash Radio • Standard interface compatible with Windows-based pen PCs, PDAs and laptops • Plugs into any compact flash port (or PCMCIA via inexpensive adapter) Confidential

  10. CCU – Simplex SAT • As the “hub,” the CCU “concentrates” information from several wireless sensors and relays the information via satellite to a backoffice system • Communications: GlobalStar Simplex (FTP to FD/customer) • Local keypad and display Confidential

  11. MGW (Modbus Gateway) • Interfaces to any standard Remote Terminal Unit (RTU) or long range radio. Modbus Slave device • Allows existing SCADA infrastructure to retrieve data from any remote iNodes sensor. • Communicates Modbus RTU protocol over RS232 • User customizable register mapping • Can be self-powered via solar panel and internal battery • Custom Device depending on customers needs Confidential

  12. Overview: Threealternatives to Globalstar’s simplex service Orbcomm is duplex but email like Cellular is very low cost and excellent throughput but may have limited applicability depending on remoteness SpaceData (SD) uses weather balloons as repeaters. Coverage is limited to south central US. Orbcomm, Cellular and Space Data CCUs Confidential

  13. iNodes in a FieldDIRECT Solution Satellite link Tank Level IHS Energy Compact Flash Radio card Wellhead Pressure Monitor Concentration & Communications Unit Handheld PC/PDA running FieldDIRECT client (optional) FieldDIRECT Data Center Electronic Flow Meter - Gas Your PC Confidential

  14. Allows user to: Poll sensors and CCU for instantaneous data Configure Alarms Calibrate transducers (marker based cals on EFM and WPM) Configure Update / Collection Schedules RF Firmware Updates View device Status / Self Tests iNode Configuration SW (PC and PDA versions) Confidential

  15. iNode Installations Confidential

  16. Regulatory Approvals • FCC Certifications • All iNode devices have been certified to comply with FCC CFR 47 Part 15: • Sensor  FCC ID: RIM-IMON • CCU FCC ID: RIM-ICCU • CFR  FCC ID: RIM-ICFR • US and Canadian Compliance • In addition, the CCU is also certified to comply with FCC Part 25 when used with the Globalstar simplex modem. • UL Certifications • iNode Sensors only (EFM, TLM1, WDS, WPM) are UL/ULc certified for Class 1, Division1, Groups C&D, T4 • UL File: E234231 Dated: 2005/04/06 Confidential

  17. Questions Confidential