Status of scintillator detector development for central part of the TOF CBM

#2. #4. #5. #1. #3. PADI. Amp. Amp. Amp. Amp. Amp. Amp. Amp. PMT2. LeCroy ADC&TDC (CAMAC). Status of scintillator detector development for central part of the TOF CBM.

rico
Download Presentation

Status of scintillator detector development for central part of the TOF CBM

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. #2 #4 #5 #1 #3 PADI Amp Amp Amp Amp Amp Amp Amp PMT2 LeCroy ADC&TDC (CAMAC) Status of scintillator detector development for central part of the TOF CBM INR (Moscow) group proposed to use scintillator detector with MAPD readout as a cheap and reliable solution for central part of the CBM TOF wall with the cell size of 20x20 mm2 This conception was experimentally tested at GSI (FOPI) in April 2009 • 3.5 GeV protons scattered at ~40 from FOPI target were used; • Start counter with two PMT readout has time resolution st~40 ps; • Six Scint (Kharkov)+MAPD-3N (Zecoteck) individual counters 20x20x20 mm3; • Amplifier with input impedance 4 Ohm, bandwidth 300 MHz and G~120 was used; • LeCroy TDC has scale 50 ps/ch. PMT1

  2. April beam test results & nearest plans Time resolution after slewing correction MAPDs were no selected before test and have different PDE! It was demonstrated that scintillator detector with MAPD-3N readout is promising for central TOF MAPD-3N (ZECOTECK) Gain vs Vbias PDE vs Vbias • Preselection of MAPDs with highest PDE; • Develop new faster preamp with lower noise; • Use of monoenergetic beam November `09 beam test at CERN

More Related