1 / 23

: Overview

V/Hz operation Horsepower Ratings: 0.25 to 5 Built-in LED Display & Keypad No need to add a separate keypad Manual Speed Potentiometer Built-in dynamic braking circuit Select separate resistor for braking Finger-safe IP20 enclosure is standard.

Download Presentation

: Overview

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. V/Hz operation Horsepower Ratings: 0.25 to 5 Built-in LED Display & Keypad No need to add a separate keypad Manual Speed Potentiometer Built-in dynamic braking circuit Select separate resistor for braking Finger-safe IP20 enclosure is standard. Can be easily modified to accommodate NEMA 1 applications with a kit addition. The kit allows for a conduit connection. : Overview

  2. : Drive Ratings Voltage Ratings: • 100 to 120 V AC Input: • 1-phase input • 3-phase, 0 to 230 V output • 200 to 240 V AC Input: • 1- or 3-phase input • 0 to 230 V output • 380 to 480 V AC: • 3-phase input • 0 to 480 V output

  3. ¹ Height dimension includes optional NEMA 1 / IP30 kit ² Height dimensions without optional NEMA 1 / IP30 kit Bottom View w/o NEMA 1 / IP30 Kit : Dimensions mm (inches)

  4. Overload Protection: 150% current for one minute 200% current overload for 3 seconds Carrier Frequency: 2 to 16kHz (Generally the higher the setting the quieter the motor) Output Frequency: 0 to 240 Hz Power Dip Ride-Through: minimum 500 milliseconds w/o Fault Protection: Under-voltage, Over-voltage, Motor-overload, Over-current, Ground-Fault & Drive Over-temperature Braking: Internal Dynamic Brake IGBT : Electrical Specifications

  5. UL Listed for USA • cUL Listed for Canada • C-Tick for Australia • CE Marked for Europe • Input Mains Filter Option for European EMC Directive Compliance : Global Design Single Phase, 230Vac Units available with optional integral filter for CE compliance IGBT Module

  6. : Mounting Flexibility • Compact Dimensions minimizes required panel space • Keypad & Local Speed Pot allow operation Out-of-the-Box • Screw or DIN Rail Mount with Zero Stacking capability • Optional NEMA 1 Kit allows conduit connection Standard IP20 • DIN rail or panel mounting for 50°C ambient • Zero Stacking up to 40°C ambient Nema 1 (IP30 ) kit • Field installed option for 40°C ambient

  7. 2 programmable inputs provide additional control flexibility Dedicated inputs for start, stop and reverse operation provide simplicity DIP switch selection for 24Vdc sink or source control provides flexibility RS485 : Control Wiring

  8. Display LED’s identify operation and direction, as well as unit values. : Startup is Fast & Simple • Control keys on the keypad are active Out-of-the-Box for immediate operation • 10 most common parameters categorized in the “ Basic Parameter Group ” to shorten & simplify startup • P031 Motor Nameplate Voltage • P032 Motor Nameplate Current • P033 Motor Overload Current • P034 Minimum Frequency • P035 Maximum Frequency • P036 Start Source • P037 Stop Mode • P038 Speed Reference • P039 Accel Time 1 • P040 Decel Time 1 4 Status LED’s indicate modes as well as operation

  9. : Key Control Parameters Start Input: (Setup P036) • Pushbutton on front keypad • Terminal 02 Hardwired Input • 2-wire or 3-wire control logic • 2-wire includes 10msec response to Start input Stop Input: (Setup P037) • Pushbutton on front keypad • Terminal 01 Hardwired Input • Coast to Rest • Ramp to Rest • DC Injection Braking Speed Reference: (Setup P038) • Drive potentiometer • Digital Speed setting from keypad • 0 to 10V Analog • 4 to 20 mA • Preset Speed (4 set-points)

  10. : Performance Out-of-the-Box Performance • Good Low Speed Torque • Good Constant Torque • Good Constant HP performance • Good torque generation, with • 150% for one minute overload rating Package with a Wide Range of Reliance Electric Motors • XE • V*S Master • RPM-AC

  11. : PC Configuration Common Configuration Software as used with SP600 AC Drives. V*S Utilities • Windows Explorer look and feel • Left side tree view • Right side parameter list • HTML help • Parameter Upload / Download • Configure parameter settings • Monitor I/O activity • Compare files • Can copy parameter files to multiple MD60 drives for ease of start-up

  12. : Under Development • Remote NEMA 4 keypad • Copy-Cat keypad • Dynamic Brake resistor Kit • Use existing Reliance DB resistors today • 3HP, 230V 1-phase and 3-phase (C frame)

  13. Performance 50HP SP600: SVC, Flexibility, Feature Set HP Range - 1/2 to 50HP 10HP MD60 w/ SVC (Early 2003) Adding Versatility: • Dynamic Braking • 16kHz switching • PC Software • NEMA 1 Kit MD60 V/Hz SP200 SP120 Power rating (HP) 0.25 0.5 3.0 5.0 : Product Positioning

  14. : “The Right Choice” • MD60 provides a product line extension from SP600 • It accommodates customers that only desire V/Hz performance in a simple package from 0.25 to 5 HP. • MD60 replaces to SP120 & SP200 to simplify our product line. • Easier to do business with RE • Minimizes inventory at all levels • MD60 is a more competitive product in the 0.25 to 5 HP range. A market segment where customers base their buying decisions heavily on price.

  15. MD60 Appendix Slides These are for reference only when technical details are required by the customer.

  16. : Environmental Specs • Ambient temperature • -10 to + 50° C IP20 • -10 to + 40° C w/ NEMA 1 kit • Relative Humidity: • 0 to 95% non-condensing • Vibration spec(operating): • 1G peak, 5 to 2000 Hz • Shock spec (operating): • 15G peak, 11msec duration • Altitude: • 1000m (3300 ft) w/o derating

  17. Rated output power 1/4 to 1 HP (115 V input) 1/4 to 5 HP (230 V input) 1/2 to 5 HP (460 V input) 150% current overload for one minute 200% current overload for 3 seconds Efficiency: 97.5% (typical) Carrier Frequency: 2 to 16kHz Output Frequency: 0 to 240 Internal Dynamic Brake IGBT Digital Input Accuracy: +/-0.05% of set output frequency Analog Input Accuracy: +/-0.5% of Maximum Output Frequency Relay Output: Form C Contact 3A resistive at 30VDC, 0.5A inductive at 30VDC Power Dip minimum ride through of 500 milliseconds w/o Fault Under-voltage, Over-voltage, Motor-overload, Over-current, Ground-Fault & Drive Over-temperature protection : Electrical Specifications

  18. Digital Input Configuration Input terminals 5 and 6 are configurable, allows for jog, preset speed selection, accel/decel 2 selection, local keypad selection Relay Output Selection Preset Frequencies (4 Presets) Jog Setup DC Braking Dynamic Braking Setup V/Hz Curve Selection Start Boost setting select VT/CT S-Curve Linear or S-Curve accel/decel Adjustable Current Limit Auto Restart Setup Set retries and Delay Start at Power Up Selection Flying Start Enable : Advanced Start-up Parameters

  19. : Adjustable Features • 2 or 3 wire control accommodates either maintained or momentary start methods. • Automatic torque boost provides robust out of the box torque performance reducing the need for manual adjustments. • Carrier frequency adjustment provides optimization for low audible motor noise (2.0 - 16 kHz) • Motor overload current to match motor full load amps (FLA). • Primary acceleration and deceleration rates provide smooth, energy saving starts • Minimum and maximum speed limits prevent known extremes that can damage equipment. • Linear or S-curve acceleration and deceleration modes. • Monitor 19 separate Display values

  20. : Performance Out-of-the-Box Performance • Good Low Speed Torque • Good Constant Torque • Good Constant HP performance • Good torque generation, with • 150% for one minute overload rating • Adjustable V/Hz curve • Adjust Start Boost for improved starting torque • +/-2% Speed Regulation • 40:1 Operating Speed Range • 10:1 Constant Torque production

  21. External filters are available for all 3-phase as well as 115V 1-phase ratings. : EMC Filters for CE Compliance • Short cable distance filter meets EN55011 • Class A to 5 meters • Class B to 1 meter • Further testing will be performed for actual results • Long cable distance filter meets EN55011 • Class A to 100 meters • Class B to 25 meters

  22. : Migration from SP120 & SP200

  23. : Comparison to SP600