30 likes | 147 Views
MAVEN-PFP-MAG-EM1 Tap Test Tue, 11 Oct 2011, UCB SSL, JW Bonnell , J McCauley. MAVEN-PFP-MAG-EM1 PWA, in frame, with stiffening plate, with all fasteners but one torqued to 4 in-lbs, placed on ESD-safe bag on linoleum flooring over concrete.
E N D
MAVEN-PFP-MAG-EM1 Tap Test • Tue, 11 Oct 2011, UCB SSL, JW Bonnell, J McCauley. • MAVEN-PFP-MAG-EM1 PWA, in frame, with stiffening plate, with all fasteners but one torqued to 4 in-lbs, placed on ESD-safe bag on linoleum flooring over concrete. • Several runs with three single-axis (Z-axis) accelerometers placed on or near PWA. • Vibration excited with sharp strokes of 28-oz deadblow hammer within 6 in of PWA. • Accelerometer locations: • CH01, on top of CP13; CH02, on top of UX02, or off board; CH03, on top of UY07.
CH03 - On UY07 (upper right quad) CH01 - On CP13 (upper left quad) CH02 - On Floor