An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. S. Banerjee, O. Kodolova HCAL DPG report Sunanda Banerjee – SINP Olga Kodolova – SINP MSU July 19, 2012

  2. HCAL General Meeting Outline • Monitoring and calibration LED/Laser for gain updates HF Raddam monitoring HF Raddam with data HBHE raddam monitoring • Phi-symmetry • LUTs generation

  3. HCAL General Meeting HBHE drift from 2011 to 2012 V.Epshteyn D.Vishnevskyi Gain updates is done regularly by Hcal Ops and is uploaded into condition DB by Database group: we need to have the gain tag to start the first 2012 calibration pass – this week or beginning of the next?

  4. HCAL General Meeting HF Radiation damages measurements with raddam system

  5. HCAL General Meeting HF Radiation damages measurements with data Indication of HF radiation damage were observed in 2011 2012: Jun/Apr Data selected with HLT_Mu17_mu8 as relative change of E deposited in HF rings and corrected by NPV. Need to be combined with raddam measurements Robert Chieleski See update tomorrow, July 20, HCAL DPG

  6. HCAL General Meeting HBHE first raddam measurements Depth1 L.Turchanovich N.Kulagin V.Skvortsov V.Talov V.Epshteyn D.Vishnevskyi Need to recheck with other measurements? Need to have HPD correction to verify what data see

  7. HCAL General Meeting Radiation damages: need to be done • Extract correction coefficients combining raddam measurements and data response (update tomorrow) • Introduce raddam into simulation

  8. HCAL General Meeting Phi-symmetry corrections in 2012 First pass was done both with Iterative (24 mlns) and NZS (~2 mlns) – check the machinery. Generally, corrections obtained are rather close to 1, with RMS ~2-3% There are a few channels iphi=67 that are deflected. Perhaps, there are some HV problems. Phi-symmetry with NZS shows the good agreement with iterative method in HF. HBHE requires more statistics. We will do the recalibration after new gains will be uploaded.

  9. HCAL General Meeting LUTs generation and validation • While conditions changed LUTs need to be regenerated 1. Verify changes to conditions files used to generate LUTs 2. Confirm desired changes in input LUTs 3. Check correlation between conditions and LUTs 4. Perform an L1 rate estimate with new LUTs (with and without HF) - next slide 5. Confirm data vs. emulation TP agreement with first data Completed for LUT validations: Physics2012v1a Physics2012v2 Physics2012v3 Physics2012v4 Complete list of conditions, offline tags, and LUTs: https://twiki.cern.ch/twiki/bin/view/CMS/HcalL1TriggerObjectsTags2011 Pablo Goldenzweig, Pawandeep Jangir

  10. HCAL General Meeting LUTs generation and validation Pawandeep Jangir

  11. HCAL General Meeting Back-up

  12. HCAL General Meeting Calibration procedure from 2011 to 2012 • HPD and PMT gain drift HPD gain drift correction once per month (as in 2011) PMT gain drift correction once per week (roughly each ~1/fb) due to much higher degradation rate of gains in PMT (change w.r.t. 2011) • HF Fibers degradation Radiation damage correction in HF based on the radiation damage measurements once per month (depends on the measurement) (change w.r.t. 2011) We consider HF is correctly calibrated with Z->ee corrections for the 2012 startup • The above corrections as HcalGain condition IOV will be uploaded by creation to _express, _prompt and _offline tags and (by agreement) to _hlt tag

  13. HCAL General Meeting Calibration procedure (continuation) • phi-symmetry corrections with iterative and NZS method (as in 2011) during technical stops while the needed statistics is available • Isolated track calibration (as in 2011) during technical technical stops while the needed statistics is available • Absolute scale in HF with Z->ee corrections (Long fibers). Short fibers will be calibrated using Long fibers calibration and MC correction for ratio between Long and short taking into account RadDam estimation for Short fibers • The above corrections as HcalRespCorrs condition IOV will be uploaded by approval to_express, _prompt, _offline and _hlt tags