1 / 8

Laser Ablation ICP-MS at the University of Gothenburg

Laser Ablation ICP-MS at the University of Gothenburg. Thomas Zack , Johan Hogmalm , Dave Cornell Department of Earth Sciences, University of Gothenburg, Sweden. Research tool : LA-ICP-MS . Flexibility and innovations possible due to compartmentalization. Microscope. Laser. ICP-MS.

rusti
Download Presentation

Laser Ablation ICP-MS at the University of Gothenburg

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Laser Ablation ICP-MS atthe University ofGothenburg Thomas Zack, Johan Hogmalm, Dave Cornell Department of Earth Sciences, University of Gothenburg, Sweden

  2. Research tool: LA-ICP-MS Flexibilityandinnovationspossible due tocompartmentalization Microscope Laser ICP-MS Carrier gas Sample holder Laser: 213 nmNd:YAGlaser, fullyautomizedstagecontrol Sample holder: Large Format Cell (10 x 10 cm) (bigsamples, fast wash-out, bettersensitivity) Carrier gas: Addition ofnitrogentoenhancetransportefficiency ICP-MS: Agilent 7500a; 2nd vacuum pump forenhancedsensitivity

  3. Currentstatusandfuture plan 2006 2014? + Reaction gas (O2) 16O2+ 16O2+ 32S+ 48Ca/48Ti, 36Ar12C 32S16O+ • Agilent 7500a • Li to U (not H, C, N, O) • ng/g @ 100 µm, µg/g @ 4 µm • ..polyatomicinterferences • Agilent 8800 • Tackle „difficultelements“: • …S, P, Cl, As, Se, Br • 10x more sensitive! • .polyatomicinterferences 32S+  32S16O+ 48Ca/48Ti, 36Ar12C Q2 (m/z 48) – rejects all ions apart from m/z 48 Q1 (m/z 32) – rejects all ions apart from m/z 32

  4. MethoddevelopmentrelatedtoEconomicGeology • Halogens (Br, Cl) in minerals • Origin of hydrothermal fluids • Breakthroughs: • Reductionofbackground (Brtrap) • DetectionlimitforBr <5 ppm • TestingofglassstandardsforBrand Cl Köhler et al 2008

  5. MethoddevelopmentrelatedtoEconomicGeology • Traceelements (e.g., Au, PGE) in sulphides • Invisible gold, oredepositmodels, geometallurgy • Breakthroughs: • Availibilityofexcellentsulphidestandards (Mass-1, Po-724) • Standardizationwithout EMP data

  6. MethoddevelopmentrelatedtoEconomicGeology Traceelements (e.g., Au, PGE) in sulphides

  7. MethoddevelopmentrelatedtoEconomicGeology • Other projects • Accessorymineraldating (rutile, monazite, titanite) • Magnetite fingerprinting • Gold in rutile • S andPb isotopes • Traceelementmapping Large et al 2009

  8. CollaborationsrelatedtoEconomicGeology Boliden Larver 2 master CGS Bushveld Hammond Tasman NorraKärre 1 master Agnico Eagle Dalsland 1 master LKAB Kiruna 1 bachelor Du Pont world-wideMcLimans VedantaGamsberg Moses

More Related