1 / 16

LDEQ

LDEQ. RECAP Miscellaneous Topics. Exposure Assessment. Site-specific under MO-3 only Construction worker scenario Greatly reduced ET, EF, and/or ED Site-specific data should be documented. Exposure Assessment. Absence of site-specific data  Default values

sabina
Download Presentation

LDEQ

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. LDEQ RECAP Miscellaneous Topics

  2. Exposure Assessment • Site-specific under MO-3 only • Construction worker scenario • Greatly reduced ET, EF, and/or ED • Site-specific data should be documented

  3. Exposure Assessment • Absence of site-specific data  Default values • Permanent vs non-permanent structures • Enclosed structures

  4. Exposure Assessment Additional exposure considerations when the site-specific GW2 or GW3 DAF is large: • Construction worker exposure • Volatile emissions to ambient air (GWair) • Cross-media transfer - migration to deeper zones

  5. Toxicity Assessment • Unavailability of toxicity values • Develop a toxicity value(s) • Identify a surrogate toxicity value based on structure/activity and/or targets • Route-to-route extrapolation • Qualitative evaluation

  6. Toxicity Assessment • No speciation data ex) Cr+3 vs Cr+6 • New slope factor ranges in IRIS • Dermal toxicity values • If GI absorption efficiency < 50%  adjust oral tox value • If GI absorption efficiency > 50%  do not adjust • RAGS HHEM Supplemental Guidance Dermal Risk Assessment Interim Guidance (EPA 1998)

  7. Background Data • Where should samples be collected? • How many samples??? • How should the data be used? • Calculate arithmetic average • Obtain Department approval • Compare to arithmetic average for AOI • What if there are high anthropogenic bg levels???

  8. TPH Issues • TPH-G, TPH-D, and TPH-O • Physical/chemical properties presented • Soilsat and Watersol not applicable • Target organs/critical effects identified

  9. Wet Weight vs Dry Weight • Data is routinely reported on wet-weight basis • Wet weight used for exposure concentrations • Dry weight used for EF&T calculations • Wet weight  Dry weight

  10. Soil to Groundwater PathwaySPLP Data • Where should SPLP samples be collected? • How is the SPLP data used to evaluate the soil to gw pathway? • SoilGW1: Compare SPLP to GW1 x DFSummers • SoilGW2: Compare SPLP to GW2 x DFSummers x DF2 • SoilGW3: Compare SPLP to GW3 x DFSummers x DF3

  11. Soil to Groundwater PathwaySPLP Data • If SPLP <, then screen out soil to gw pathway • If SPLP >, then delineate area of concern • SPLP vs TCLP • SPLP vs LRS

  12. Estimation of Sd Sd = Thickness of impacted groundwater within permeable zone Sd = 5’ 10’ 5’ Un-impacted groundwater Impacted groundwater 15’

  13. Estimation of Sd Sd = Thickness of permeable zone if thickness is not known or if the zone is not impacted Sd = 15’ 10’ Un-impacted groundwater 15’

  14. Alternate RS • MO-3 only • Technically impracticable and/or economically infeasible ONLY • Corrective Action Study • Requires Department Approval

  15. Workplans • Required for MO-3 • Recommended for some MO-2 • The more detailed, the better • Id of AOI/COCs • CSM • Id of approaches/methods • Id of assumptions/site-specific and default inputs

  16. Fractional Organic Carbon Fractional Organic Carbon (foc) - Estimated by dividing the percent organic matter (POM) by a conversion factor of 174 - POM determined using ASTM D2974 - Samples should be collected from a non- impacted area at a depth consistent with the depth of impact - Default foc = 0.006