1 / 10

ALLEGRO data during E7 Presenter: Martin McHugh

ALLEGRO data during E7 Presenter: Martin McHugh. Recent/current activities. Stochastic DSO handles both ifo-ifo and bar-ifo cross correlations Frames of E7 data have been made using code written by Ed Daw ALLEGRO undergoing transducer upgrade will NOT take data during S1 aiming for S2.

Download Presentation

ALLEGRO data during E7 Presenter: Martin McHugh

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ALLEGRO data during E7Presenter: Martin McHugh LSC meeting, LIGO Hanford Observatory

  2. Recent/current activities • Stochastic DSO handles both ifo-ifo and bar-ifo cross correlations • Frames of E7 data have been made using code written by Ed Daw • ALLEGRO undergoing transducer upgrade • will NOT take data during S1 • aiming for S2 LSC meeting, LIGO Hanford Observatory

  3. Complications • Heterodyning – bar data is in-phase and quadrature output of a lock-in amplifier with reference frequency 907 Hz • sampling rate – 250Hz • dynamic range – raw output is 2 sharp lines at the bar resonant frequencies LSC meeting, LIGO Hanford Observatory

  4. Bar–ifo Stochastic Analysis Chain • Bar: • Whiten data (response function alone leaves spectrum with big ‘dips’) – frequency domain or time domain ? • Form response – de-whitening function • Two-sided psd of result • Pass data to DSO LSC meeting, LIGO Hanford Observatory

  5. Interferometer: • mix with reference of appropriate frequency (907Hz) and phase • resample complex times series 16384Hz to 250Hz • take 2-sided psd • pass data to DSO LSC meeting, LIGO Hanford Observatory

  6. Extra mechanical resonance Detector resonaces Calibration line Power line harmonic LSC meeting, LIGO Hanford Observatory

  7. LSC meeting, LIGO Hanford Observatory

  8. LSC meeting, LIGO Hanford Observatory

  9. LSC meeting, LIGO Hanford Observatory

  10. Questions • Rotating the bar between X-arm alignment and Y-arm alignment flips the sign of the GW correlation – allows cancellation of correlated noise • Null orientation gives measure of correlated noise • What’s the optimal amount of time in each of these orientations? LSC meeting, LIGO Hanford Observatory

More Related