An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Surface Plasmon Resonance Portable Biochemical Sensing Systems Karl Booksh School of Biochemistry Arizona State University (Tempe) Denise Wilson Department of Electrical Engineering University of Washington (Seattle) National Science Foundation, Grant #ECS0300537

  2. Surface Plasmon Resonance Portable Biochemical Sensing Systems ECS0300537 • The Big Picture • Why SPR? • Highly sensitive (10-4 to 10-6 RI units) • Very local (10-100nm from sensing surface) • Directly indicative (of interactions between sensor and environment) • Relatively unencumbered by sampling overhead (e.g. tagging, mixing, etc) • Readily referenced to compensate for background fluctuations (e.g. drift) • How is it used (SPR = transduction mechanism)? • Non-functionalized = bulk refractive index • Functionalized = specific analytes • The Full Spectrum of SPR-based instruments • User-Intensive, Single Measurements: Biacore • User-Intensive, Single Field Measurements: TI Spreeta (Chinowsky/Yee) • Distributed and Autonomous, Multiple Measurements: • Insertion-based probes • Compact signal processing • Streamlined, robust optical path

  3. Surface Plasmon Resonance Portable Biochemical Sensing Systems • Who are we? • Karl Booksh, Biochemistry, Arizona State University (Probes and Functionalization) • Denise Wilson, Electrical Engineering, University of Washington (Signal Processing and Systems Integration) • Are we interdisciplinary? Tight integration of biochemistry and electrical engineering • Goal of this Research • Surface Plasmon Resonance • Field monitoring at numerous locations • What defines the problem? • Ability to sense specific analytes at high sensitivity/low detection limit • With high resilience to ambient fluctuations • light, temperature, • other factors that influence bulk refractive index • In a manner that allows continuous sampling with little overhead • In a footprint that is non-intrusive or easily carried (handheld)

  4. Sample Surface Plasma Wave Evanescent Wave Metal θinc Substrate Incident Light Reflected Light Optical Fiber w/ Cladding Gold Coating Exposed Core Surface Plasmon ResonancePortable Biochemical Sensing SystemsBasic Operation When the wave vector closely matches that of the surface plasmon at the metal-sample interface, reflected light is significantly attenuated ko = 2p/l

  5. Surface Plasmon ResonancePortable Biochemical Sensing Systems Configurations • Point of resonance can be detected at a • Particular angle (constant wavelengh interrogation) • Particular wavelength (constant angle interrogation) • Constant Angle • Polychromatic light source at constant angle of incidence • Constant Wavelength • Monochromatic light source at different angles of incidence Constant Angle is chosen here for: inexpensive light source, easy alignment, and simpler, more compact configuration (= less overhead)

  6. Surface Plasmon ResonancePortable Biochemical Sensing SystemsSensor Design • Sampling Options: • In-line • “Dip” insertion-based probe • The probe configuration is : • easily replaced, easy to use • Less prone to sensor layer blocking, • but can be • more sensitive to ambient fluctuations • more susceptible to fouling

  7. Air Surface Plasmon ResonancePortable Biochemical Sensing SystemsTypical Output Increasing RI Raw Data (background overwhelms resonance) Referenced Data (Resonance is evident)

  8. Multivariate Calibration Communication/ADC Overhead Measurement to Reference Ratio High Resolution Regression Low Resolution Regression Multivariate Calibration Surface Plasmon ResonancePortable Biochemical Sensing SystemsSummary of Effort Approach #1 (Traditional) Software High Resolution Photodetection Approach #2 (Voltage-Mode, Partially Integrated) Software Integration Time Programming Low Resolution Photodetection “Flatlining” Reference Ratio

  9. Approach #4 (Current-Mode, Fully Integrated) Software Multivariate Calibration Multivariate Calibration Dark Current Compensation Low Resolution Regression Low Resolution Photodetection “Flatlining” Current Scaling Approach #3 (Pulse-Mode, Fully Integrated) Software “Flatlining” Current Scaling Low Resolution Regression Low Resolution Photodetection Conversion to Pulse Mode Surface Plasmon ResonancePortable Biochemical Sensing SystemsSummary of Effort

  10. Surface Plasmon ResonancePortable Biochemical Sensing SystemsSystem-on-Chip Implementations Approach #2 All Designs are mixed signal, fabricated in standard CMOS Approach #4 Approach #3

  11. Pixel Analog Sampling Phototransistor Digital Control Surface Plasmon ResonancePortable Biochemical Sensing SystemsSystem-on-Chip Implementations 15 pixel array fabricated on a 1cm2 die in the 1.5 micron AMI process through MOSIS 2mm

  12. Surface Plasmon ResonancePortable Biochemical Sensing SystemsSystem-on-Chip Implementations

  13. Surface Plasmon Resonance Portable Biochemical Sensing Systems • What’s the bottom line? • Benchmarking has shown system-on-chip to be competitive with software solutions • Compact, low user-overhead, low-power SPR nodes have been enabled: • Environmental Monitoring (e.g. coastal/ocean/freshwater) • Denise sensor networks for maintaining public safety (e.g. water supply) • Biomedical applications (e.g. point of care, preventative heart attack monitoring) • Students (3 MS, 2 undergraduate, 2 of which are women) • Outreach/Broader Impact • SPR modeling and simulation integrated into electronic nose toolbox • www.ee.washington.edu/research/enose • Technology Transfer • Probe design is patented and licensed to two companies in Phoenix • SOC designs are fabricated in standard CMOS • Optical components are modular and readily available

  14. Surface Plasmon Resonance Portable Biochemical Sensing Systems • Publications • Denise M. Wilson and Lisa E. Hansen, “Current-mode System-on-Chip for SPR Sensing Systems,” IEEE Sensors Journal, submitted for publication, June 2006. • Lisa E. Hansen and Denise M. Wilson, “System-on-chip Surface Plasmon Resonance Sensors Using Pulse-based Interface Circuits,” IEEE Sensors Journal, submitted for publication, March 2006. • M.W. Johnston, Lisa E. Hansen, and Denise M. Wilson, “System-on-Chip Circuit Architecture for Eliminating Interferents in Surface Plasmon Resonance Sensing Systems,” IEEE Sensors Journal, submitted for publication, January 2006. • Lisa E. Hansen, Matthew Johnston, and Denise M. Wilson, “System-on-chip Surface Plasmon Resonance Sensors Using Pulse-based Interface Circuits,” IEEE Sensors: Irvine, California, October 2005. • Matthew Johnston, Denise Wilson, Karl Booksh, and Jeffrey Cramer, “Integrated Optical Computing: System on Chip for Surface Plasmon Resonance Imaging,” Intl. Symp. Circuits and Systems, ISCAS: Kobe, Japan, May 2005. • Lisa Hansen, Matthew Johnston, and Denise Wilson, “Pulse-based Interface Circuits for SPR Sensing Systems,” Intl. Symp. Circuits and Systems, ISCAS: Kobe, Japan, May 2005. • Denise M. Wilson, Mike Warren, Karl Booksh, and Louis Obando, “Integrated Optical Computing for Portable, Real-time SPR Analysis of Environmental Pollutants,” Eurosensors 2002: Prague, Czech Republic, September 2002.