320 likes | 591 Views
Russell Prevost. Tel: 770.326.2132 FAX: 770.326.2051 Cell: 678.576.9220 Email: Russ.Prevost @ Siemens.com. Mechanical Limit Switches. International Style, 3SE3 North American Style, 3SE03 Accessories, 3SX. SIGUARD / Safety. Interlock Switches, 3SE3 Hinge Switches, 3SE3
E N D
Russell Prevost Tel: 770.326.2132 FAX: 770.326.2051 Cell: 678.576.9220 Email: Russ.Prevost @ Siemens.com
Mechanical Limit Switches • International Style, 3SE3 • North American Style, 3SE03 • Accessories, 3SX SIGUARD / Safety • Interlock Switches, 3SE3 • Hinge Switches, 3SE3 • Cable-Operated Switches, 3SE7 • Magnet Switches, 3SE6 • 2-Hand Operator Console, 3SB3 • Safety Relays, 3TK28 • Load Feeders, 3RA71 Terminal BLocks Supplementary Protectors • Supplementary Protectors, 5SX, 5SY, 5SP4 • Fuse Components, 5S • Fuse Holders, 3NW • 8WA1 Screw Connection • 8WA2 Spring Loaded • 8WA3 Insulation Displacement (Availability to be Announced) Product Responsibility Introduction
Estimated NEMA Market – Estimated Supplementary Protector Shipments Shipments in Millions Market Data F = Fiscal Year = October 1 through September 30
Industrial Controls Catalog Item # CPPC-06000-0803 Resources - Catalogs SiteScape: Controls – D, DX, T, V Modules \ Marketing and Sales Collateral \ 6. 2004 Industrial Controls Catalog Resources
Resources - SiteScape • Sign onto SiteScape at: http://sitescape.sea.siemens.com/forum/aca-1/dispatch.cgi/customer_forums/workspace/8272680 sea.siemens.com/forum/aca-1/dispatch.cgi/_admin Under “Workspaces” select “Product Information’ • Select ‘Controls – D, Dx, T, V Modules’ • Select ‘Products’ • Select ‘IEC Control’ Resources
3. Catalog & Configuration Aids • Catalog Page Update: 5SY in 5 A, 15A, 30A, 35A, 45A & 60A; 1, 2 & 3 Poles Resources – Supplementary Protectors on SiteScape SiteScape: Controls – D, DX, T, V \ Products \ IEC Control \ 3. Catalog & Configuration Aids \ 6. Addendum to Catalog Pages 12/9 and 12/10 Resources
Resource - 5SY Demo Case • Every Controls Business Development Specialist has one “Big Blue Case” • The Case Includes • 5SY4 & Accessories • 5SP4 • 5SX2 • 8WA1 • 8WA2 • Contact your local BDS for availability Resources The Controls Catalog, Section 12, is the only literature on Supplementary Protectors
What is Supplementary Protection? Introduction
Tripping Characteristics Thermal Characteristic D A
Supplementary Protector Family – Section 12 UL1077 Supplementary Protector Applications New Customers Existing Selection 5SY4 0.3-63A 5SP4 80-125A 5SX2 0.3-63A
5SY4 Supplementary Protector • Rated current: 0.3 – 63 A. Recently added5, 15, 30, 35, 45 & 60A 1, 2 & 3 Pole C Tripping Characteristic Versions • Certified according to UL 1077 and CSA 22.2 No. 235-M 89 • Rated breaking capacity: 14 kA @ 120/240VAC5 kA @ 277/480VAC • Tripping characteristic: A, B, C, D • Number of poles: 1-, 2-, 3-, 4-pole, 1+N, 3+N • Mounting depth: 70 mm • Mounting width (Single Pole): 18 mm Selection
5SY4 Supplementary Protector Features Complete Catalog Number printed on side of device!! Tabs for DIN Rail removal without tools Plastic Guards for finger-safe protection Window for visible trip indication Features Extended Handle for easier access
5SY4 Supplementary Protectorwith Add-on components and Accessories UL Handle Locking Device 5ST3 Terminal Cover Cap Auxiliary Contact (AS) UL 5ST3 Fault Signal Contact (FC) Padlock Accessories 5ST3 Shunt Trip (ST) 5SY 5ST3 End Cap Undervoltage Release (UR) Busbar
UL Listed Busbar for use with UL1077 Supplementary Protectors • Competition for UL508 Busbar • Merlin Gerin: 1 busbar for 12 1-pole devices (can not be cut) • Altech: Complete family of 1, 2, & 3-pole busbars • FUJI: Complete family of 1, 2, & 3-pole busbars • Siemens will offer UL508 busbar for 5SY4 in the 3rd Qtr of Calendar 2005 • 1, 2, & 3-pole busbar • Cut to length • Due to UL508 creepage and clearance requirements, it will be larger than the IEC busbar currently available Accessories
5SP4 Supplementary Protector • Rated current: 80 - 125 A • Certified according to UL 1077 and CSA 22.2 No. 235-M 89 • Rated breaking capacity: 14 kA @ 120/240VAC5 kA @ 277/480VAC400A @ 60VDC (per pole) • Tripping characteristics: B, C and D • Number of poles: 1-, 2-, 3-, 4- pole • Mounting depth 70 mm • Mounting width 27 mm Selection
5SP4 Supplementary Protector with Add-on components and Accessories Handle locking device UL 5ST3 Auxiliary Circuit Switch(AS) UL 5ST3 Padlock Fault Signal Contact (FC) Accessories 5ST3 Shunt Trip (ST) 5SP4 5ST3 Undervoltage Release (UR) Terminal Cover Cap
Supplementary Protector Comparison Selection
55 70 70 Supplementary Protector Comparison Selection
5ST301* Auxiliary current switch (AS) and 5ST302* Fault signal contact (FC) Versions: • 1NO + 1NC; 2NO; 2NC • UL 1077 and CSA 22.2 No. 235-M 89 Ratings: • max. contact load capability: NO contact: NC contact: 2A, AC 400V, AC-14 2A, AC 400V, AC-13 6A, AC 230V, AC-14 6A, AC 230V, AC-13 1A, DC 220V, DC-13 1A, AC 220V, DC-13 1A, DC 110V, DC-13 1A, AC 110V, DC-13 3A, DC 60V, DC-13 3A, AC 60V, DC-13 6A, DC 24V, DC-13 6A, DC 24V, DC-13 AS Accessories Applications: • Indicates the switching condition of the MCB: - AS: ON/OFF - FC: tripped only FC
5ST303*: Shunt Trip (ST) Not UL Listed Versions: • for voltages: AC 100 to 415V, DC 110V DC 24 to 48V Ratings: • Trip limits acc. to DIN VDE 0660 Part 100 Accessories Applications: ST • remotely tripping the MCB
5ST304*: Undervoltage Release (UR) Not UL Listed Versions: • For voltages: AC 230V, DC 110V, DC 24V Ratings: • Trip limits acc. to DIN VDE 0660 Part 100 Accessories Applications: • can be used as remote release in an EMERGENCY OFF circuit • if the voltage is interrupted or too low the UR trips the device or prevents it from being closed • guarantees that the controlled circuit is disconnected acc. to EN 60 204 UR
5ST3 7: Busbar, End cap Not UL Listed Features: • pin connections single- and multi-phase 16 mm² copper, fully insulated 18 mm lug clearance Versions: • Length 12MW, fully insulated: 1-, 2-, 3-, 4- phase; 1-, 2-, 3- phase + AS; 3 x (1- phase + AS); 3/N + 8 connections • Length 56MW, without end caps: 1-, 2-, 3-, 4- phase; 1-, 2-, 3- phase + AS; 3 x (1- phase + AS); Accessories End caps: 5SH5 514; 5ST3 718 • 2-, 3- and 4- phase
5ST38**: Terminal cover cap, Handle locking device, Padlock Not UL Listed Terminal cover cap: 5ST3800 • Useful for all pole varieties • sealable • for covering the screw opening • prevent removing of the device from the DIN rail Handle locking device: 5ST3801 Accessories • Useful for all pole varieties • sealable against unwanted ON- and OFF- switching • Padlock with max. 3 mm frames Padlock: 5ST3802 • For handle locking device 5ST3 801
What is UL 489? Introduction
Phase I: 5SJ4, Single Pole with Spacing Between Poles December 2005 UL489 Circuit BreakerApplications Phase II: 1, 2 & 3 Poles – No Spacing Between Poles Required 2nd Qtr FY06 New Product – Mini Circuit Breaker in IEC Housing New Product
5SJ4 Circuit Breakers per UL489 A&D ET is developing UL489 versions of the 5SY4 family • Step 1: 4th Qtr Calendar 2005 • 5SJ41 without additional barriers • 1-pole breakers only • No spacing if adjacent mini breakers are of the same polarity • B, C & D Trip Curve versions • Planned short-circuit ratings: 15kA @ 2400 VAC, 10kA @ 60 VDC • Step 2: 2nd Qtr Calendar 2006 • 5SJ4* with additional barriers • 1, 2 & 3-pole breakers • Will allow for side-by-side mounting • C & D Trip Curve versions • Step 1 Product Competition: • Allen Bradley • ABB • Merlin Gerin • Moeller • Step 2 Product Competition: • ABB • Merlin Gerin New Product