An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Energy Systems Division, Ajou University Introduction to the Energy Issues: Starting from Power Sector Energy Modelling Lab. Department of Energy Studies, Energy Systems Division, Ajou University Prof. Suduk Kim suduk@ajou.ac.kr

  2. Question! 01000001 1 Byte = 8 bits ASCII Code American Standard Code for Information Interchange

  3. Apple II -> Year 1977 My First personal Computer, year 1985!!! 1 Byte = 8 bits X 2^10 1024 Byte = 1KB 48KB Question! How many times bigger? USD 1 = KRW 1150 USD 214= KRW 247,000

  4. Electric Power& Tariff How much of electric power to be consumed if this computer is ‘power on’ for one whole month? 150W x 24Hourx 30Days = 108,000Wh = 108kWh

  5. Understanding of Units Source: http://en.wikipedia.org/wiki/Nano-

  6. Korea Nuclear Power Plants(Kori) One Nuclear Power Plant Capacity 1GW = 1,000MW = 1,000,000kW

  7. Photovoltaic • East Sun Power Gen. Co. • 24MW, 0.7Mil m2 , US 200Mil. • 1 Nuclear Power Plant => • 1GW = 1000MW • 24MW x 40 approx. 1000MW Capacity : to be equivalent to 1 Nuclear Power Plant (x 40 times) -> 28 Mil m2 , US 8,000 Mil. (US 8 Bil.) Power Generation: to be equivalent to 1 Nuclear Power Plant (x 5 times) (with capacity factor of 20%, tracking device) -> 140 Mil. m2 , US 40 Bil. ** Still we don’t get power during the night, rainy days,…

  8. Technical Advancements (ex: Wind) Source: SRREN, IPCC, 2011

  9. Power Mix Change Since Late 1970s Source: Data compiled from KESIS Note: Figures after 2010 are projections taken from MKE (2010).

  10. Ilustration of SMP, based on the merit order of March 2010 Q: Is hydropower to be included in this merit order? Q: Is Hourly load always to be vertical? What if it is not?

  11. Economics of Smart Grid (Demand Response) • the need to have a framework to facilitate the Demand Response in power market • the Importance of the bilateral information exchange