1 / 9

ITEP Beam Chambers P.Gorbunov (U. of Toronto and ITEP, Moscow)

ITEP Beam Chambers P.Gorbunov (U. of Toronto and ITEP, Moscow). Features: X-Y MWPCs with cathode DL r/o working area: 120 ×120 mm 2 gas: Ar-CO 2 (80:20); HV: 2.25 kV detection efficiency ≈ 100% accuracy: 120 – 200 μ readout channels: 6 (analog) availability: 4 (currently in H6)

sibyl
Download Presentation

ITEP Beam Chambers P.Gorbunov (U. of Toronto and ITEP, Moscow)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ITEP Beam ChambersP.Gorbunov (U. of Toronto and ITEP, Moscow) • Features: • X-Y MWPCs with cathode DL r/o • working area: 120×120 mm2 • gas: Ar-CO2 (80:20); HV: 2.25 kV • detection efficiency ≈ 100% • accuracy: 120 – 200 μ • readout channels: 6 (analog) • availability: 4 (currently in H6) • built in 2002 • Successfully used in Fcal TB2003 and OPERA’2002 (nuclear emulsion) CBT EC2 Planning meeting CERN

  2. Technical features • Two identical chambers (X- and Y-) in common housing • Anode planes: 25 wires, 20 μ, 6 mm spacing • Cathode planes: 31 wires, 100 μ, 4 mm spacing, ┴to anodes • Anode-to-anode: 26 mm • Calibration pulser signals can be injected to cathode wires 7,16 or 25 (3000 pulser events at start of each run) • Lumped delay line with 10 ns cells • More on the design and comparison with MC simulation: • cern.ch/atlas-fcaltb/Memos/Hardware/BPB/BPC_Note1-2003.pdf • cern.ch/atlas-fcaltb/Memos/Hardware/BPC/ITEP_BPC_design_Rus.doc (in Russian) • Real rate limit: ~30 kHz • No multitrack measurement (rejection only) CBT EC2 Planning meeting CERN

  3. Readout electronics 10 ns±1% 4 mm • Analog constant-fraction shaping (to reduce time-walk) : front-end • TDC LeCroy 2228A (11 bit, 250 ps) • ADC LeCroy 2249A • Extternal NIM discriminators LeCroy 623 • Custom calibration pulser L calibration pulses R w7 w16 w25 D TDC ADC X ≈ GX ( tL– GRLtR - t0 ) CBT EC2 Planning meeting CERN

  4. Y “old” ITEP BPCs CH#1 CH#2 CH#3 CH#4 X Y X Y X Y X Y X Y X Y cryostat beam Z B9 1.6 m Z 27 m X 2.2 m 27000mm 100mm ITEP BPCs in H6 beam line • two “stations” of 2 BPCs: near & far • an auxiliary mid-station with 4 “old” BPCs (300 μ resolution) • advantages of arranging BPCs in pairs: • better space resolution (<100 μ, important for the near station!) • δ-electron rejection (see below) • easier cabling CBT EC2 Planning meeting CERN

  5. Space resolution σX(mm) • has been studied in dedicated test beam measurements, confirmed in H6: σ = 110-200 μ, depending on the hit position. • σ is ~constant across the measurement direction (across anodes) and deteriorates towards the edge cathode wires • MC shows that the tails of dX >1 mm are due to δ-electrons • The cut |dX|<1 mm has ε=97% (|dX|<0.5 mm: ε=95%) and largely eliminates δ-electrons 0.2 0.1 x dX (meas-pred), mm CBT EC2 Planning meeting CERN

  6. BPC calibration • Internal calibration (GX, to) –with an external pulser, at start of run • GRLand G adjustment, mutial alignment of all chambers: with beam tracks • For most of the BPCs, the calibration drift during FCal TB runs was negligible. Exeptions: ch. 1 and one case of a faulty TDC to (Y5) to (Y1) GX (Y1) Bad TDC CBT EC2 Planning meeting CERN

  7. Multi-track rejection >1 track • Can rely on external counters… trust but verify! • tR+ tLfor single tracks has a lower limit = Σ line delay • Anode signal amplitude Summary • ITEP BPCs: new beam chambers, designed for high-accuracy measurements • No visible ageing effects • robust, easy to maintain and read-out CBT EC2 Planning meeting CERN

  8. BPC resolution: H6 data dX=X(1)-X(2), 30x40 mm2 dY=X(5)-X(6), 60x60 mm2 Y X X Y σ12≈150 μ σ56≈190 μ CBT EC2 Planning meeting CERN

  9. Y D C B A X Impact point prediction Fcal1 Fcal-1 response, ADC counts X, cm Y, cm CBT EC2 Planning meeting CERN

More Related