An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Preliminary Experiment Result Of Linear Optics Correction G. Wang T. Satogata May 27th, 2009

  2. Typical measured phase (set 15)

  3. Measured Baseline Phase-beat (set 1-6) Drive at 0.01 above betatron tune

  4. Measured Baseline Phase-beat (set 7-12) Drive at 0.01 below betatron tune

  5. Measured Phase-beat For 1 Pre-set Error (set 13-18) bo6-tq6 was set to 0.002, drive at 0.01 above betatron tune

  6. Measured Phase-beat For 1 Pre-set Error (set 19-24) bo6-tq6 was set to 0.002, drive at 0.01 below betatron tune

  7. Reconstructed Trim Quad Errors From Measured Phase-beat bo6-tq6 was set to 0.002

  8. Measured Phase-beat For 2 Pre-set Errors (set 25-30) bo6-tq6 and bo10-tq6 were set to 0.002, drive at 0.01 above betatron tune

  9. Measured Phase-beat For 2 Pre-set Errors (set 25-30) bo6-tq6 and bo10-tq6 were set to 0.002, drive at 0.01 below betatron tune

  10. Reconstructed Trim Quad Errors From Measured Phase-beat

  11. Summary • Typical rms phase-beat uncertainty is about 0.04 radian or 2.3 degree, which is around 20% for our typical phase-beat measurement. • We are able to reconstruct the trim quadrupole errors for the chosen bo6-tq6 and bo10-tq6, which do not have large SVD components in small eigenvalue modes (and thus have more tolerance for noises). • In the next experiment, we plan to use other trim quadrupoles to correct one specific trim quadrupole error (test effectiveness of knobs).

  12. Thank you!

  13. Noise Level: 0.015 (~20%) Noise ~20%

  14. Trim Quads Error is Reconstruct able with Proper Cut @ Noise Level: 0.015 (~20%) Noise ~20%