1 / 33

" IEEE Dallas EMC, September 16, 2003 presentation by Teccor Electronics

" IEEE Dallas EMC, September 16, 2003 presentation by Teccor Electronics. Contact information . Phillip Havens, Technical Product Management Engineer 972-518-9427 phillip.havens@teccor.com www.teccor.com 1800 Hurd Drive, Irving, TX 75038. FCC P 68 UL 60950. FCC P 68 UL 60950 UL 497.

solada
Download Presentation

" IEEE Dallas EMC, September 16, 2003 presentation by Teccor Electronics

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. "IEEE Dallas EMC, September 16, 2003 presentation by Teccor Electronics

  2. Contact information • Phillip Havens, Technical Product Management Engineer • 972-518-9427 • phillip.havens@teccor.com • www.teccor.com • 1800 Hurd Drive, Irving, TX 75038

  3. FCC P 68 UL 60950 FCC P 68 UL 60950 UL 497 GR 1089 UL 60950 UL 497 GR 1089 UL 60950 UL 497 GR 1089 UL 60950 Application of Regulatory Requirements Central Office Outside Plant Subscriber Premises MDF SLIC switch DDF Customer Premise Equipment (CPE) Street Cabinet SLIC APP if on DLC system O/H Cable U/G Cable Wall Plug, Network Interface Device (NID) POTS SPLITTER SLIC MDF trunk line T1, HDSL, or HDSL-2

  4. Regulatory Requirements • GR 1089 Issue 3 Oct 2003 • Electrical safety (surge and current limiting) • LEC offices and CPE locations • TIA-968-A • Lightning • Customer premises equipment (CPE) • UL 60950 • surge • power cross

  5. Regulatory Requirements • ITU K.20/21 • Metallic and longitudinal surges • Power Cross • Coordination issues

  6. ITU K.20/21 • K.20 covers central office type of equipment • K.21 covers customer premises type of equipment • Two levels: • Basic • Enhanced

  7. ITU K.20 surges • BASIC applied ± 5 times • 5x310 25A for single port w/o primary • 5x310 37.5A for multiple port application w/o primary • 5x310 100A must coordinate w/primary • ENHANCED • 5x310 37.5A for single port or multiple port w/o primary • 5x310 150A to eliminate need for primary

  8. ITU K.21 surges • BASIC applied ±5 times • 5x310 37.5A for single port or multiple port w/o primary protectors • 5x310 100A must coordinate w/primary • 8x20 1 kA to eliminate need for coordination • ENHANCED • 5x310 150A for single port or multiple port w/o primary protectors • 5x310 150A must coordinate w/primary • 8x20 5 kA to eliminate need for coordination

  9. ITU K.20/21 coordination • Coordination with the primary • not required for BASIC IF: • capable of withstanding 8x20 1kA surge ± 5X • not required for ENHANCED IF: • capable of withstanding 8x20 5kA surge ±5X • Coordination not required if primary is not “specified” (the agreed to primary protector clause)

  10. ITU K.20/21 Power Cross • BASIC • 600 volt, 1A for 1 second • ENHANCED • 1500 volt, 7.5A for 2 seconds • AND a series of 15 minute tests at 230 volts with 10,20,40,80,160,300, and 600 ohm test resistor (fuse allowed to open for BASIC and first 4 conditions for ENHANCED)

  11. SIDACtor - What is it? • Over-voltage Protection For: • Telecommunications Equipment • CATV Equipment • Security Systems • Data Communications • Thyristor Applications

  12. SIDACtor - How Does it Work? • Turns on with voltage • Turns off with current

  13. SIDACtor - How to Select • Vdrm > Peak (DC) operating voltage of protected circuit • Vs > Withstand voltage of protected circuit • Ih(MIN) > Short circuit DC current of protected circuit • Ipp > Anticipated surge current of regulatory requirements

  14. SIDACtor V-I Curve +I IT IS IH IDRM -V +V VT VDRM VS -I

  15. TeleLink Fuse - over current protection • A surge tolerant fuse element • Surface mount package • 1.25A current rating for F1250T • .5A current for F0500T • Helps applications comply with: • UL 60950 • GR 1089 • TIA-968-A

  16. Application Circuits • T-1/E-1 • T3 • ADSL/ xDSL • VDSL intra-building • VDSL inter-building • SLIC (subscriber line interface circuit)

  17. Application Circuits • SLIC (subscriber line interface circuit) • Ethernet 10/100 BaseT • ISDN • Transformer Protection

  18. T1/E1 Protection

  19. T3 Protection

  20. ADSL/xDSL Protection

  21. VDSL intra-buiding Protection

  22. VDSL inter-building Protection

  23. HDSL Protection

  24. SLIC Protection

  25. Ethernet 10/100BaseT Protection

  26. ISDN Protection

  27. Transformer Protection

  28. 5-pin modules

  29. 5-pin modules

  30. 5-pin modules

  31. 6-Pin Dual Balanced Protector

  32. 6-Pin SLIC Protector

  33. 6-Pin Battrax

More Related