1 / 27

Introducing the LIGHTNING MVP

The LIGHTNING MVP instrument offers a single solution for testing surface hygiene, water quality, pH, and more. With user calibration, advanced software, and rechargeable battery, it provides accurate, centralized data for effective process monitoring. The instrument's design ensures durability and reliability, allowing for easy data analysis and trend identification. Purchase the LIGHTNING MVP for streamlined testing processes and improved insights into sanitation and HACCP compliance.

ssisneros
Download Presentation

Introducing the LIGHTNING MVP

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Introducing theLIGHTNING MVP • One Instrument • Multiple Tests • One Report

  2. Why multiple parameters? • Monitoring both sanitation and HACCP • Consistency of data and test methods • Data centralized allowing analysis and trending of multiple parameters for expanded insight into processes • Accuracy of results • All data automatically logged • Single-step upload to PC • Cost savings • Single instrument purchase • One unit to maintain and handle

  3. LIGHTNING MVP Instrument • Lightweight and portable – weighs 1.5 lbs. • Rugged and durable • User calibration of all parameters to ensure GMP and HACCP compliance • Customer defined fields allows for advanced results analysis • Rechargeable lithium ion battery • One-step download to a PC

  4. Multiple Tests • Surface hygiene and water qualitywith ATP Bioluminescence Sampling Devices • Conductivity and Concentration/ppm with MVP Conductivity Probe • pHwith non-glass MVP pH/Temperature Probe • Temperaturewith MVP Temperature Probe

  5. One Report • Single database stores, manages, and integrates results • LIGHTNING MVP TRAX software is easy-to-use for simple trending to complex analysis of multiple indicators • LIP program • Summarizes performance of each plant in a corporate report • Provides benchmarking between plants and industry at large

  6. Technology sampling device insertion mechanism • Advanced Microprocessor • Photomultiplier Tube (PMT) light sensing device • PMT, the most sensitive part of the instrument, protected by dark chamber • Secure sampling device insertion mechanism • Sealed casing to protect from liquids and plant hazards Instrument sealed Battery housing Light stabilized dark chamber

  7. Light Stabilized Dark Chamber • MVP can reliably detect very low levels of ATP: • 1 x 10-15 moles or 15 x 10-12 grams of ATP • 1 femtomole or 15 picograms (0.000,000,000,015 grams of ATP) • Patent pending photometric isolator prevents PMT from being inadvertently exposed to light • Better accuracy and longer life of PMT

  8. Zones or RLU’s • MVP sensitivity range is 300 to 300,000,000 photon counts • MVP does not “zero out” luminometer like competitors • Zones of Cleanliness provide a means to normalize the data by converting it to a log scale • Zones of Cleanliness range from 0 to 7.5.

  9. Zones vs RLU’s 1000000 100000 10000 Zone 1000 RLU 100 10 1

  10. MVP ATP Sampling Device Base chamber Plunger Swab tip and Test Tube

  11. Dry Chamber L/L pellet and desiccant Wet Chamber Buffer liberates ATP sample from swab tip and combats effects of sanitizers Piercing PinForced through two chambers, thoroughly mixing components Swab Shaft Reagent travels down hollow shaft, to swab tip evenly rinsing ATP sample from swab tip

  12. MVP ATP Sampling Device • Swab is positioned above the light path read by the MVP • Only reagent mixture read, not the swab tip • Regardless of how you turn the swab, the reading will always be the same! Reagent is forced through swab tip from inside out and evenly washes ATP off swab into aqueous solution Read Chamber in light path of MVP

  13. Accuracy of MVP Sampling Devices Sampling device design offers superior accuracy and repeatability OtherBrand MVP Relative Standard Deviation Within each swab 8.5% 0.50% Between swabs 44% 5%

  14. Sanitizers and MVP Sampling Devices • Buffer solutions neutralize the effect of sanitizers • Sanitizers can quench or accelerate light output which reduces the reliability and credibility of an ATP system

  15. MVP pH/Temp Probe ISFET (Ion Sensitive Field Effect Transistor) Technology Non-glass, ideal for in-plant usage Non-breakable 3 buffer calibration MVP Temperature Probe Stainless steel standard thermometer -20°C to 105° C Single point calibration MVP pH & Temperature Probes

  16. Measures both conductivity and concentration 0-100,000 microSiemens (S) 10-200,000 parts-per-million (ppm) Concentration parameter reads sanitizers and cleansers Measures temperature (0° C – 100° C) Specifications: 4-graphite electrode cell design, epoxy body Single calibration point Automatic temperature compensation MVP Conductivity Probe

  17. MVP TRAX Software • Powerful, yet simple-to-use • Transfer results at the push of a button • Allows trending and analysis of individual measurement parameters • Analyze and integrate data from multiple indicators which allows users to identify potential cause/effect relationships

  18. TRAX Single Variable Trend

  19. TRAX Multi Variable Trend 14.0 100 13.0 90 Zone/pH 12.0 Temp 80 11.0 10.0 70 9.0 60 8.0 Zone pH 7.0 50 Temp 6.0 40 5.0 30 4.0 3.0 20 2.0 10 1.0 0.0 0 1 2 3 4 5 6 7 8 9 10 11 Test Points

  20. LIP Program • LIGHTNING Index Proficiency (LIP) service exclusively available to LIGHTNING customers • Corporate report comparing all plants • Plant-level analysis of monthly performance • By product line • By test point • By surface type

  21. LIP Corporate Report Plant Means Current Month vs 13 Month Mean 7.0 6.0 5.0 4.0 Mean Zone Value 3.0 2.0 1.0 0.0 01023000418 01023000454 01023000352 01023000275 01023000229 01023000037 Plant Code Current Month mean 13 Month Mean

  22. LIP Corporate Report Surface Type Means

  23. LIP Plant Detail Reports Results by Zone Range Results by Surface Type

  24. MVP System Components • MVP Instrument • MVP System Guide • MVP Accessories • batter charger (international plugs) • MVP serial cable • MVP Y adaptor • Carrying strap • MVP Software CD • TRAX software • Configuration software

  25. MVP System Services and Support • 12 Month Service Warranty • Replace units at no charge within warranty period • Installation and training at every plant • Instrument operation • Swab technique • Sampling plan • Software installation and training • Annual Certification • Training and re-certification at every plant • LIP program enrollment • Custom analysis of each plant • Corporate report • Technical Support

  26. MVP System Accessories Sampling Devices • MVP ATP Surface Sampling Device • MVP Liquid Sampling Device • MVP pH/Temperature Probe • MVP Temperature Probe Other • MVP Protective Case • MVP ATP Calibration set • MVP Positive Controls

  27. LIGHTNING MVP System • The LIGHTNING MVP is not just another ATP system • It is a multi-parametric instrument that will become a key tool to for your HACCP and SSOP verification procedures