Cardiac Conduction

Cardiac Conduction. Physiology of Cardiac Conduction. The excitatory & electrical conduction system of the heart is responsible for the contraction and relaxation of the heart muscle. The sinoatrial node (SA node) is the pacemaker where the electrical impulse is generated.

stanislaw
Download Presentation

Cardiac Conduction

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Cardiac Conduction

  2. Physiology of Cardiac Conduction • The excitatory & electrical conduction system of the heart is responsible for the contraction and relaxation of the heart muscle. • The sinoatrial node (SA node) is the pacemaker where theelectrical impulse is generated.

  3. Cardiac conduction pathway • SA node fires to the AV node through gap jxn’s • AV node delays 0.1 s for atrial diastole • AV node fires to the AV bundle (HIS) • AV bundle depolarizes through right & left bundle branches • Bundle branches carry impulses through Purkinje fibers to the ventricular myocardium for ventricular systole Total time of conduction = 0.22 s

  4. Nodal Firing Rates • Sa node = 75 b.p.m. • AV node = 50 b.p.m. • AV bundle = 30 b.p.m. • Purkinje fibers = 30 b.p.m. What would happen if the SA node could not conduct an impulse to the AV node? Heart block (no gap jxn’s found between atria & ventricles)

  5. How to Read an

  6. Electrocardiogram Paper • A grid system where time is measured along the horizontal axis. • Each small square is 1 mm in length & represents 0.04 seconds. • Each larger square is 5 mm in length & represents 0.2 seconds.

  7. ECG Voltage • Is measured along the vertical axis. • 10 mm is equal to 1mV.

  8. Heart rate can be calculated from the EKG strip • When the rhythm is regular, the heart rate is 300 divided by the number of large squares between the QRS complexes. • For example, if there are 4 large squares between regular QRS complexes, the heart rate is 75 (300/4=75).

  9. Heart rate can be calculated from the EKG strip • Can be used with an irregular rhythm to estimate the rate. Count the number of R waves in a 6 second strip and multiply by 10. • For example, if there are 7 R waves in a 6 second strip, the heart rate is 70 (7x10=70).

  10. Quick Quiz • True or false • On a typical EKG grid, 5 small squares, or 1 large square, represent 0.20 seconds of time True

  11. PQRST wave

  12. Deflection waves P wave • Lasts 0.08 s • Results due to depolarization from SA node throughout atria • Atrial systole • Normal duration is not longer than 0.11 seconds (less than 3 small squares) • Amplitude (height) is no more than 3 mm

  13. Deflection waves QRS complex • Lasts 0.08 s (Normally not longer than 0.10 s in duration) • Results due to depolarization of ventricles • Ventricular systole & atrial diastole • R waves are deflected positively and the Q and S waves are negative T wave • Results due to repolarization of ventricles • Lasts 0.16 s • Ventricular diastole

  14. Normal ECG Deflection Wave Pattern

  15. Abnormal ECG Deflection Wave Patterns Sinus Bradycardia Rate = 40-59 b.p.m.

  16. Sinus Tachycardia • Rate = 101-160 b.p.m. • Causes • CHF, hypoxia, pulmonary edema • Increased temperature • Stress or response to pain

  17. Sinus Arrhythmia Rate = 45-100 b.p.m.

  18. Sinus Arrest Causes Myocarditis MI Digitalis toxicity

  19. Atrial Flutter Rate = 250-350 b.p.m. Precipitates CHF

  20. Atrial Fibrillation (afib) Causes COPD CHF

  21. AV block • Causes • Digitalis toxicity • Acute infection • MI • Degeneration of the conductive tissue.

  22. Ventricular Tachycardia (V-tac) Rate = 100-220 b.p.m. • Causes • CAD • Acute MI • Digitalis toxicity • CHF

  23. Ventricular Fibrillation (V-fib) Causes Acute MI

  24. Asystole