1 / 28

Varian 940-LC Analytical to Prep HPLC

Varian 940-LC Analytical to Prep HPLC. Varian 940-LC Silver Bullets. The 940-LC one instrument – many uses: High performance automated Analytical HPLC High performance semi-preparative HPLC High performance prep LC. Varian 940-LC Silver Bullets. Flexible and capable

steedb
Download Presentation

Varian 940-LC Analytical to Prep HPLC

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Varian 940-LC Analytical to Prep HPLC

  2. Varian 940-LC Silver Bullets • The 940-LC one instrument – many uses: • High performance automated Analytical HPLC • High performance semi-preparative HPLC • High performance prep LC

  3. Varian 940-LC Silver Bullets • Flexible and capable • Wide flow rate from 0.1 ml/min to 200 ml/min • Dual path-length flowcells for extended Abs • One Injector, analytical or prep volumes (5ul to 4.5ml) • Superb fraction collecting • Galaxie real-time peak detection • Practical collect and inject • Much Easier interface, it does what you tell it! • Cleaner UI

  4. Goals of the 940-LC Analytical to Prep • Aim • Become market leader in this $180M segment • Double market share • Market • Continue to focus on Pharma / BioPharma • Academic • Strategy • Deliver innovation in hardware, consumables, software and services

  5. Varian 940-LC Instrument Overview • Factory tested, pre-plumbed instrument: • Plug and play operation • High performance semi-preparative HPLC • Gradient Analytical HPLC • Autoprep System • Choice of UV or PDA detector • Dual path flow cell for unmatched range and scalability • No compromise performance for prep and analytical – switch with a key stroke – no plumbing or hardware changes needed! • The most flexible analytical to prep HPLC available

  6. Varian 940-LC Instrument Overview • Scale-up Module for automated methods transfer from analytical to semi-prep, or switching from Analytical to Prep work • Versatile and robust solvent-delivery system • New loopless autosampler – wide volume range • NEW Fraction collection with • Complete range of collection modes such as slope, threshold and time slicing • Wide range of vessels, including autosampler rack • Comprehensive range of columns and consumables • More productivity via GalaxieTM software • Valve automation for genuine unattended operation • NEW direct control interface

  7. Varian 940-LC Versatility and Performance • Easy to change pump heads • Versatile solvent delivery systems • Powerful pumps allow 4000psi at 25mL/min operation for fast chromatography • Ideal for 4.6mm and 1” column • Able to use smaller 3 & 5 um particles columns at elevated pressures • Improves productivity • Save solvents and waste costs • Short run times save time • High resolution separations = high purity 1ml/min Analytical 21ml/min Prep

  8. Varian 940-LC Solvent Delivery System • Same range of accessories as PS210/218 • 5ml Head to 200ml Head • Seal wash option available • Easily interchangeable pressure modules thru removable side panel. • Easy access to mixer • Self maintenance and versatility features have been completely retained with no compromises – integrated systems are notoriously difficult to maintain so this is Unique

  9. Varian 940-LC Autosampler • Prep version of the 920-LC Sampler • 5ul to 4.5ml Injection range • No necessity to combine a Manual injector • No need to dedicate injector to prep or analytical • One Sampler does all! • Loopless Design • Variable injection volume • Needle in path Design • No carryover

  10. Varian 940-LC UV-Vis Detector • High Sensitivity for Analytical applications • Extended absorbance – desensitised, for prep applications • All in one detector • Wide l range 190 to 900 nm • Low noise of < 5 x 10-6 Au • Self –aligned D2 lamp • Consistent performance • Easy to change over without tools • Front panel access • Easy to maintain

  11. Information Rich Diode Array Detection • 1024 photodiodes full coverage from 190 – 950 nm • Full l spectra collection • Enhanced peak purity parameter • Automatic peak identification with customised libraries • Greater confidence on compound identification • Choice of flowcells • Dual path length scale-up • Dual path length Prep • Front panel access • Lamps and flowcells • D2 and Vis lamps self aligned • Easily user maintained

  12. Varian 940-LC PDA Detectors • PDA allows enhanced peak purity determination • Galaxie uses whole spectrum across peak to determine purity

  13. Varian 940-LC Dual Pathlength Flowcell • Absorbance Detector • Extended absorbance range without re-plumbing (<70 AU) • NEW 4mm x 0.25 mm • 4mm x 0.15 SuperPrep • Low dispersion • UV/Vis Detector • PDA Detector • Low noise ~ +10 mAU • Low Drift ~ 1 mAU/hr

  14. Competitors Flowcells

  15. Varian 380-LC and 385-LC ELSD • Universal HPLC detector • Compatible with gradients • More sensitive than RI • NEW Glass Nebuliser for Improved Reproducibility • 2 to 3 Times More Sensitive • 40Hz Data Rate for Fast LC • Complete Galaxie compatibility • Program changes thru a run

  16. Varian 440-LC Fraction Collector • Full software control with foolproof collection by slope, threshold, volume or timeslice • Known fluid path for accurate fraction collection • Software display of collected fractions and source injections • Reliable operation • Compatible with a wide range of containers • Belart and other optional racks • Microvial to 50ml tube capacity • Autosampler rack compatibility provides practical collect and re-inject capabilities

  17. Varian 440-LC Fraction Collector • We chose not to collect Peak 3 • Peaks 1,2,4,5,6,7 collect with exceptional accuracy • Excellent algorithm, and simple delay volume calculation • Slope/Threshold based on real numbers!!

  18. Varian 440-LC Fraction Collector • Fraction Log shows peak location using colour coded rack assignment

  19. Optimized flow paths for automated scale-up Separate optimised flow paths for Prep and Analytical columns Solvent selection valves for 4 solvents (2 per pump) Integrated priming valves for easy solvent changes Integrated electrically actuated valves for analytical and prep Injections Clear cover to protect operators against leaks Varian 445-LC Scale-up Module

  20. Varian 940-LC Software Usability • Software designed for Prep users • Enhanced manual control • One page status and chromatogram • Real time fraction collection display • Advanced peak sensing for better fraction collection • Purity displays for absorbance detection – standard! • Documentation and audit trails for traceability and regulatory needs

  21. Varian 940-LC Integrated HPLC • Special features of the Varian 940-LC • Leak detector • Increases confidence with unattended automated runs • Single waste point • Ensures capture of all wastes • Easy to connect to waste vessel • Built-in solvent bottle storage • Improved safety and convenience • Lower hight than modular systems • Bottle management software • Protects columns and results on unattended automated runs

  22. Varian 940-LC Integrated HPLC • Special features of the Varian 940-LC • Clear front doors • Stylish • Provides access to autosampler without opening doors • Enhanced safety as lab staff shielded from solvent spray and leaks (100ml/min at 4000 psi) • Useful, convenient storage compartments • Column rack in door • Operation log drawer

  23. Varian 920-LC Integrated HPLC • Special features of the Varian 920-LC • Leak detector • Increases confidence with unattended automated runs • Single waste point • Ensures capture of all wastes • Easy to connect to waste vessel • Built-in Solvent bottle storage • Improved safety and convenience • Lower hight than modular systems

  24. Varian 920-LC Integrated HPLC • Special features of the Varian 920-LC • Clear front doors • Stylish • Provides access to autosampler without opening • Safety increased as lab staff shielded from solvent spray and leaks • Useful, convenient storage compartments • Column rack in door • Operation log drawer

  25. Varian 920-LC AIQ (Validation) • AIQ (Analytical Instrument Qualification) • Fully PC controlled IQ and OQ (not PQ) • Puts the Varian 920-LC at the forefront of regulated capabilities • Consistent, reproducible methodology • Includes pumps, autosampler, detectors, column heater • Chargeable option • Fully documented

  26. 900 LC -Series AIQ • Full system test designed and implemented as part of the 900-LC Series Analytical Instrument Qualification package. • Verifies the entire LC system by systematically running the following • Flow Rate Accuracy Test • Wavelength Detector Accuracy Test • Auto-sampler Injector Accuracy Test (also measures Detector Linearity) • Auto-sampler Injector Precision Test • Auto-sampler Injector Carryover Test • Proportioning Accuracy Test • Detector Noise Test • Detector Drift Test • Auto-sampler Vial Identification Accuracy Test • Proportioning Linearity • Compositional Ripple

  27. Varian 940-LC Configurations -XX where 00=AUS, 01=Eur, 02=US

  28. Varian 940-LC Consumables • Columns designed for Prep users • From 3 to 10mm media • Wide range of C4 to C18 • Silica and Polymer media • From 2mm to 2” ID • Unique solutions for dedicated prep with load and lock systems • Matched Analytical to Prep columns and packing's to assure smooth scale up • Solutions for hardware, software and consumables

More Related