Food Monitoring Systems for the Detection of Radionuclides in Food and Water

Food Monitoring Systems for the Detection of Radionuclides in Food and Water. Contaminated Food All Over the News. Complementing Approaches to Food Monitoring. Food monitoring systems designed to work out of the box Simple to use interface for quick data entry

takara
Download Presentation

Food Monitoring Systems for the Detection of Radionuclides in Food and Water

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Food Monitoring Systems for the Detection of Radionuclides in Food and Water

  2. Contaminated Food All Over the News

  3. Complementing Approaches to Food Monitoring • Food monitoring systems designed to work out of the box • Simple to use interface for quick data entry • Configurations for both Administrators and Operators • Clear results and reports

  4. FoodGuard-1 NaI Food Monitoring System • 3” x 3” NaI detector • USB connected digiBASE that combines a preamp, high voltage, and MCA all in one • Full system precalibrated and tested in factory • PC and printer preloaded with software and calibration files • Simple interface for fast set up and testing • KClchecksource integrated into shield for regular calibration checks • Six 1L marinellis included with system • Measured MDA of 14 Bq/l in 30min.

  5. FoodGuard-1 Software • Designed to move users from setup to results as fast as possible • Intended for scientists and non-scientists alike • Clear and easy to use interface decrease human error • Functionality defined for both Supervisors and Operators • Multiple reporting options to review results • Screens for most common radio nuclides from nuclear power plant events • 131I, 103Ru, 134Cs, 137Cs

  6. FoodGuard-1 Setup • Password protected for Supervisors • Wizard walks through performing calibration check • Simple entry boxes to define sample types, sample names, etc. • Set overall system settings • Define alarms based on absolute levels and percentages

  7. FoodGuard-1 Run and Results • Easy data entry through drop down menus • Enter samples as volume or weight • Audible and visual feedback of exceeded alarms • Multiple reporting options for different views on the data

  8. FoodGuard-1 Ordering Options • FOODGUARD-1-PC • A complete NaI food monitoring system including all hardware, software, and preconfigured PC and printer • FOODGUARD-1 • Software and hardware to complete a food monitoring solution with a customer supplied computer and printer • 1L-MARINELLI-CASE • Additional case of 1L marinelli beakers for use with the FoodGuard-1 system

  9. FoodGuard-2 HPGe Food Monitoring System • High resolution system to achieve lower MDA levels in a shorter count time • Edit custom nuclide libraries to expand nuclides being tested • Professional and customizable HTML and PDF reports • Options for both detector efficiency and cooling mechanism • Precalibrated and tested at factory • Ships with six 2L Marinelli beakers • Includes 2L KClchecksource

  10. FoodGuard-2 Setup • Settings only available to Supervisor • Calibration check with included checksource • Set up of additional system parameters similar to FoodGuard-1 • Additional options to report in Bq or convert to microCuries

  11. FoodGuard-2 Alarm Setup • Includes multiple Limit Libraries derived from published limits of worldwide governement organizations • Users can create new libraries or edit existing libraries • Alarms can be set for specific nuclide activity and/or the sum of nuclides • User can add more nuclides to the Limit Libraries using a simple interface

  12. FoodGuard-2 Run and Results • Operator selects from prepopulated dropdowns to decrease human error • Multiple calibration files can be loaded to account for different sample geometries • Immediate feedback given during the run through a live spectrum display

  13. FoodGuard-2 Report Customization • Professional reports in HTML and PDF for easy sharing and archiving • XML reports can be easily customized to include company logos and additional customer information

  14. FoodGuard-2 Ordering Options • All systems come with software, MCA, shield, PC and printer • You choose: • Detector efficiency – 20-60% • Cooling options – Dewar and cryostat or X-Cooler mechanical cooler • Additional add-on options: • GammaVision Software • Dig deeper into results and create additional calibration files • ANGLE • Easily create new calibrations for different sample geometires • Nuclide Navigator • Interactively view, search, and extract detailed information from nuclide databases

  15. Additional Information • For more information regarding food monitoring and either FoodGuard-1 or FoodGuard-2, visit http://ortec-online.com/Solutions/Food-Water-Environmental-Monitoring.aspx