240 likes | 312 Views
Founded in 1979 Eindhoven Exists 33 years 09-09-2012 Independent Dutch Company Own “in house” technology Specialist in innovative secure transmission technology and ARC automation Certified Product & Services (EN Standards) Convener(s) in Cenelec Workgroups (EN)
E N D
Founded in 1979 Eindhoven • Exists 33 years 09-09-2012 • Independent Dutch Company • Own “in house” technology • Specialist in innovative secure transmission • technology and ARC automation • Certified Product & Services (EN Standards) • Convener(s) in Cenelec Workgroups (EN) • Partner in Concepts & Total Solutions Ron Heij CEO ASB-Security BV Partner forGreece & Cyprus: Automatic Alarm Systems S.A. We are all going IP, are youready?
New Trends: • The awareness of the use of standards (defined quality- and performance criteria) • Security EN50131 (alarm system), EN50136 (alarm transmission) and EN50518 (ARC’s) • (ARC = Alarm Receiving Centre) • Use of IP, GPRS and UMTS networks for (alarm) transmission • PSTN -> IP conversion for traditional alarm systems • full (native) IP-alarm systems • Integration and/or interaction with other systems • likeAccess Control, Video, home/building automation, Energy systems etc • End user in control and informed anytime and anywhere using modern technology • use of Smart Phones, Tablets en WWW • Remote Maintenance via IP around the world using Computers, Tablets, WWW etc
Q(assistance)= Q(Electronic Alarm)x Q(Human response) Whatcan we sayabout the quality of the assistance ? What does the threatenedpersonexpect? The awareness of the use of standards Q(Electronic Alarm) Quality- and performance criteria forelectronic alarm components, installation, networks and services are described in: EN50131 series (Alarm systems) EN50136 series (Alarm transmission) EN50518 series (Alarm ReceivingCentres) EN Standards Electronic alarm Alarm Network Alarm system Alarm transmitter Alarm receiver Alarm Receiving Centre ARC notifies Police or guard(s) Assistance Human response
certiProtectOne Network certiMonitorOne EN50131 series EN50518 series EN50136 series certiFireOne Alarm Transmission System EN54-21 - EN50136 series EN54 series
Alarm transmission over IP and GPRS Migration PSTN IP
IP migration solution for PSTN alarm systems • Interfaces with any analog dialer • Serial and PSTNinterface for classATS1 - ATS6 • alarm transmission systems • IntegratedGPRS backup with SMS messages • Easy up-/download for PSTN alarm systems over IP • Automatic detection of (X)SIA, CID and Fast Format • Easy configuration via Web-user interface (wui) • Plug & Play operation • EN50136 certified - ATS1 – ATS6 /
Grade 3 Grade 1-2 Grade 3 - 4
Intruder- & Holdup Alarm System (business) • Integrated IP & GPRS • Maximum 1024 zones /users; 64 areas; 1500 event log • Maximum 64 remote keypads • Maximum 64 Mifareor third party readers • Third party IP integration for example Video • Wireless/hybrid configuration and integrated • automation functions - KNX • Remote programming via WinCCS and/or RMS • Certified conform EN50131/EN50136, Grade 3 • Control via WUI, Smart Phone and/or Tablet
In controlanytime and anywhere appsforSmartphones & tablets
Bidirectional IP Communicationwith the ARC’s
IP - RemoteMaintenance via winCCS(windows) / RMS (wui)
CertAlarmcertified • EN54-21and EN50136certified • EN54-4certifiedintegratedredundant power supply • Multiplepathreliable alarm transmission via IP and GPRS • Integrated DSL modem (optional) • Both pin and serial interfaces to the (Fire) Alarm System • Remotelymanagedusing RMS • IPv6 ready • IP-GPRS, IP-GPRS-GPRS, GPRS-GPRS (total 4 paths) • Verification of Performance compliant (EN50136)
SCSClient SCSServer SCSReporter SCSGateway SCSFEP SCSSync SCSVoice SCSOperator SCSWeb • Solution forsmall, medium and large ARC’s • Scalable, grows with customer needs • Operates standalone, network and clustered • Modulararchitecture (supports SAAS) • From250 to 250.000locations and more • Multi Screen, 1 – 50 operators and more • Easy to use, in anylanguage • Video and MAPIntegration • Integrationwiththirdparties SCSSMS SCSVideo SCSMaps SCSPDA
Centralized Web-based device management • No need for local storage of configurations • Reduces time, effort and money spent on site visits • Pro-active monitoring of any site • Secure access through SSL encryption and login • Plug & Play commissioning without port forwarding • Configuration and software version management • Web-based GUI, IPv6 ready • Verification of Performance compliant
Fire Alarm system GPRS Alarm system SCS5000 No port forwarding, NAT orfixed IP address No port forwarding, NAT orfixed IP address No port forwarding, NAT orfixed IP address BMSO-IP/GPRS Connection Connection No port forwarding, NAT orfixed IP address Connection No port forwarding, NAT orfixed IP address Connection Connection No port forwarding, NAT orfixed IP address
Questions? New trends: NEW OPPORTUNITIES Thankyouforyourattention. Presentation and more informationavailableon USB disk at Automatic Alarm Systems