430 likes | 1.25k Views
Laboratory test standards for assessment of rail fastening system performance. David Rhodes, PhD - Pandrol Ltd., UK Bob Coats, P.E. - Pandrol USA. Rail Fastening System Qualification Tests. Europe – CEN (EN 13481-2) Japan – Railway Technical Research Institute (RTRI)
E N D
Laboratory test standards for assessment of rail fastening system performance David Rhodes, PhD - Pandrol Ltd., UK Bob Coats, P.E. - Pandrol USA
Rail Fastening System Qualification Tests Europe – CEN (EN 13481-2) Japan – Railway Technical Research Institute (RTRI) North America – AREMA (Ch. 30) Global Influence (Australia, Africa + others)
Electrical Test Requirements CEN: 5 kΩ Resistance minimum After water spray, corrected for resistivity AREMA: 10 kΩ Impedance minimum After submerged soak
Determination of Longitudinal Rail Restraint BS EN 13146-1:2002
Longitudinal Restraint CEN: Pull to slip, 7 kN (1,574 lb.) minimum AREMA: 2,400 lb. (10.7 kN) without slip
Determination of Attenuation of Impact loads EN 13146-3:2002
Instructions for the Cyclic Loading on an Assembly EN 13146-4:2002
Instructions for the Cyclic Loading on an Assembly EN 13146-4:2002