CONTROL BOX RMO88.530

CONTROL BOX RMO88.530. Dedicated to:. Light oil burners. PRESS SERIES ONE STAGE TWO STAGE THREE STAGE. RL SERIES ONE STAGE TWO STAGE. Dedicated to:. Heavy oil burners. PRESS SERIES TWO STAGE THREE STAGE. RN SERIES TWO STAGE. MODELS. FEATURES. RMO88.530A2RL.

tarkington
Download Presentation

CONTROL BOX RMO88.530

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CONTROL BOX RMO88.530

  2. Dedicated to: Light oil burners PRESS SERIES ONE STAGE TWO STAGE THREE STAGE RL SERIES ONE STAGE TWO STAGE

  3. Dedicated to: Heavy oil burners PRESS SERIES TWO STAGE THREE STAGE RN SERIES TWO STAGE

  4. MODELS FEATURES RMO88.530A2RL RMO88.530A1RL Mode operation………….…... Intermittent Intermittent Main voltage…………….…... AC 220-240 V +10% -15% AC 100-120 V +10% -15% Frequency…………….…... 50-60 Hz +/-6% 50-60 Hz +/-6% Under Voltage protection…... Approx. AC 170 V Approx. AC 70 V Primary fuse…………….…... Max 16 A Max 16 A Power consumption……..…... 20 VA 20 VA Internal fuse…….……..…... T6.3H250V (IEC 127-215) T6.3 Polarity...………….……..…... To be observed To be observed >450 K (pre-purge) <200 K (operation) >450 K (pre-purge) <200 K (operation) Flame signal (photoresistence)

  5. RMO88.530A2RL RMO88.530A1RL Timings of cycle NOTES Waiting time………….…... 2 sec………………………….. Beginning when both # 4 & # 8 are energised. If not input to # 4 within 600 sec since # 8 is energised  lock out Pre-purge time (min)….…... 23 sec…………………………. Interval between # 11  # 10 outputs Pre-ignition time………….…... 22 sec………………………... Interval between # 12  # 10 outputs Post-ignition time……….…... 5 sec Ignition safety time……..…... 5 sec Interval 1st  2nd stage..…... 7 sec…………………………. Interval between # 10  # 13 outputs Interval 2st  3rd stage..…... 7 sec…………………………... Interval between # 13  # 14 outputs

  6. CONTROL PROGRAM IN EVENT OF FAULT

  7. INDICATION OF OPERATION

  8. SELF-DIAGNOSTIC Operating concept · Burner control has initiated lockout Þ Red fault LED on · Reset Press lockout reset button for about 1 s · Diagnosis of cause of fault – Press lockout reset button for > 3 s – Press again lockout reset button for > 3 s – Read blink code of red fault LED Þ «Error code table A»

  9. Error code table A Blink code Possible cause 2 x ··· No establishment of flame at the end of ignition safety time – Faulty or soiled flame detector – Faulty or soiled fuel valves – Poor adjustment of burner – Faulty ingnion equipment 4 x ····· Extraneous light during pre-purging – Or internal device fault 7 x ········ Loss of flame during operation – Poor adjustment of burner – Faulty or soiled fuel valves – Faulty or soiled flame detector 8 x ········ · Time-out release contact for oil pre-heater does not close 10 x ·········· · Wiring error or internal fault, output contact, unidentifiable fault, e.g. faults that occurred simultaneously