An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Simulation of 2-dof helicopterResults MaryamAlizadeh June 29th 2011

  2. Contents: • Introduction • Modifications • Comparison • ECG Mode • PD Controller Mode • Changing ECG in PD Controller Mode • Sampling Rate of camera

  3. Simulation block Diagram Camera Projection Model Θinc,Ψinc Xp , Yp Helicopter Model Plant Controller Ball Position in World Frame Desired Point (120,160) Helicopter & Camera position

  4. Simulink Block diagram

  5. Modifications • Real-time processing • Different sampling time for blocks • Changing camera position • ECG Mode and PD Controller parts of helicopter model

  6. Comparison Real and Simulation Test Results • Tests: • ECG mode • PD Controller • Changing ECG in PD controller mode • Changing Sampling rate of camera

  7. ECG Mode Comparison Pole trajectory by changing ECG from 0.01 to 0.1 (Experimental Tests) By increasing ECG, Poles are getting closer to imaginary axis The smaller ECG, The more stable system

  8. Pole trajectory by changing ECG from 0.01 to 0.1 (simulation Tests) By increasing ECG, Poles are getting closer to imaginary axis The simulation test results show the simulated system is more stable than real one but both have the same direction

  9. PD Controller Mode Comparison Pole trajectory by changing Kd from 0.01 to 0.1 (Experimental Tests) By increasing Kd, Poles are getting further to imaginary axis The larger Kd, The more stable system

  10. Pole trajectory by changing Kd from 0.01 to 0.1 (Simulation Tests) By increasing Kd, system is getting more stable The larger Kd, The more stable system

  11. Changing ECG in PD Mode, Kd=0.05 Pole trajectory by changing ECG from 0.01 to 0.1 while Kd=0.05 (Experimental Tests) By increasing ECG, Poles are getting Closer to imaginary axis The smaller ECG, The more stable system

  12. Pole trajectory by changing ECG from 0.01 to 0.1 while Kd=0.05 (Simulation Tests) By increasing ECG, Poles are getting Closer to imaginary axis The smaller ECG, The more stable system

  13. Sampling Rate of Camera Pole trajectory by changing Sampling rate of camera from 2 to 30 frames per second (Experimental Tests) Changing sampling rate dose not have specific effect on pole trajectory

  14. Pole trajectory by changing Sampling rate of camera from 2 to 30 frames per second (Simulation Tests) Changing sampling rate dose not have the same effect as experimental results

  15. Thank you for your attention ?