510 likes | 780 Views
Process Analyzer Sampling with Astute System. IFPAC 2008 – Baltimore January 29 ,2008. EIF FILTRES French compagny specialized since 30 years in filtration equipments and sampling treatments. .
E N D
Process Analyzer Sampling with Astute System IFPAC 2008 – Baltimore January 29 ,2008
EIF FILTRES French compagny specialized since 30 years in filtration equipments and sampling treatments. IFPAC 2008 – Baltimore January 29 ,2008 January 30 ,2008 January 30 ,2008
Our philosophy: • Leave the contaminants in process • Separate as fast as possible the contaminants from the sample • Reduce the treated volumes • Reduce and make easier the maintenance IFPAC 2008 – Baltimore January 29 ,2008 January 30 ,2008
For that, we have developed : • Cross flow filtration with blow back systems • Liq/liq coalescing filter with jet fuel separator • Gas treament column • L Type housings • Modular and smart systems IFPAC 2008 – Baltimore January 29 ,2008
CROSS FLOW FILTRATION • / BLOW BACK SYSTEMS IFPAC 2008 – Baltimore January 29 ,2008
Process Analyser High flow rate High contaminant amount Process Pipe IFPAC 2008 – Baltimore January 29 ,2008
Traditional solution Process Analyser High flow filter 2 Filter 1 Large Coalescor Process Pipe IFPAC 2008 – Baltimore January 29 ,2008
Alternative way Process Analyser Low flow rate Small contaminant amount Cross flow filter Fine filtration Small Coalescor Fast loop Low drain flow Process Pipe IFPAC 2008 – Baltimore January 29 ,2008
Cross flow filters IFPAC 2008 – Baltimore January 29 ,2008
CROSS FLOW FILTERS TAN - TAN GM with different kind of elements LIF – LIF GM – LIF - Mini with Sintered St/St element IFPAC 2008 – Baltimore January 29 ,2008
MINI – CROSS FLOW FILTER • Low dead volume • Low flow fast loop IFPAC 2008 – Baltimore January 29 ,2008
Sizing reduction IFPAC 2008 – Baltimore January 29 ,2008
BLOW BACK SYSTEM IFPAC 2008 – Baltimore January 29 ,2008
Liquid / Liquid coalescor Coalescing Element Hydrophobic membrane IFPAC 2008 – Baltimore January 29 ,2008
NESSI • Global industry initiative, formed June 2000 to drive permanent change in how process Analytical is done • CPAC sponsorised ( Center of Process Analytical Industrial) • Modular, miniature & smart sample system technilogy • SP 76 standard • Micro analytical devices IntraFlow™ IFPAC 2008 – Baltimore January 29 ,2008
This New technology Reduce the System Design Time Cut the Fabrication Expenses Improve the Analyzer Reliability Advance the Process Maintenance Easier IntraFlow™ IFPAC 2008 – Baltimore January 29 ,2008
EIF Filtres Parker representative for French analytical market IntraFlow™ IFPAC 2008 – Baltimore January 29 ,2008
ParkerIntraFlow™ PatentPending IntraFlow™ IFPAC 2008 – Baltimore January 29 ,2008
Realisations IFPAC 2008 – Baltimore January 29 ,2008
Realisations IFPAC 2008 – Baltimore January 29 ,2008
COALESCING FILTER BLOW BACK SYSTEM SEPARATOR FILTER EIF TOPWORK COMPONENTS ISA/ANSI S 76.00.02 Compliant SPECIFIC ADAPTATOR FOR ROTAMETER GAS EJECTOR
Petrochemical application IFPAC 2008 – Baltimore January 29 ,2008
Typical gazoline sampling in front of Chromatograph IFPAC 2008 – Baltimore January 29 ,2008
IFPAC 2008 – Baltimore January 29 ,2008
Specifications : • Fluid : gazoline • Filtration needed • liquid-liquid coalescing needed IFPAC 2008 – Baltimore January 29 ,2008
New design in beginning of 2006 • Cross flow filtration with blow back system • modular Intraflow assy • liquid-liquid coalescing with separator • Pneumatic control ( specific for the test) IFPAC 2008 – Baltimore January 29 ,2008
Gazoline sampling for sulphur analyzer IFPAC 2008 – Baltimore January 29 ,2008
TM Cross flow filtration To analyzer via Intra flow Blow back system DECLIF HP MINI (low dead volume) Fast loop Cross flow filter 2S2LIF GM MINI 2 microns (low dead volume) IFPAC 2008 – Baltimore January 29 ,2008
TM Gazoline treatment Coalescing housing Séparator IFPAC 2008 – Baltimore January 29 ,2008
first installations comments • Flow sheet needed • Free space needed around components with maintenance ( filters for example …) • How to install , vertically or horizontally • Drain and vent take into consideration IFPAC 2008 – Baltimore January 29 ,2008
The Answer !! IFPAC 2008 – Baltimore January 29 ,2008
3 D Solution IFPAC 2008 – Baltimore January 29 ,2008
The solution = 3D Patent Application Pending IFPAC 2008 – Baltimore January 29 ,2008
The same sampling evolution IFPAC 2008 – Baltimore January 29 ,2008
TM Fast loop Astute SCF with tangential element 0,5 microns • Compact • Top equipment easily accessible • Low dead volume IFPAC 2008 – Baltimore January 29 ,2008
ASTUTE : • SP 76 compliant • Integrated cross flow filter • Modular • Compact • Low dead volume • Upgradeable IFPAC 2008 – Baltimore January 29 ,2008
ASTUTE : • Top equipment easily accessible • Vertical and horizontal position installation possible • On the fast loop or in derivation • All the different paths on the same module( sample, standard, drain, vent ..) IFPAC 2008 – Baltimore January 29 ,2008
For the sampling: • Reduce or eliminate the sampling line • Decrease the response time • Reduce the product and drain volumes • Temperature control and heating easier • Reduce the sample contamination risk IFPAC 2008 – Baltimore January 29 ,2008
ASTUTE contribute to : • Measurement quality improvement • Cost of build and operating cost reduction • Maintenance easier • Installations sécurity improvement IFPAC 2008 – Baltimore January 29 ,2008
APPLICATIONS IFPAC 2008 – Baltimore January 29 ,2008
Flow meter Moisture sensor Pressure regulator filter IFPAC 2008 – Baltimore January 29 ,2008
TM TM DIRECT CONNECTION ON PROCESS CCIMS System ISOLATING VALVES CCIMS CLAMPS PROCESS PIPE IFPAC 2008 – Baltimore January 29 ,2008
Direct connection on process • Very short response time • Easy maintenance clamp connection • Low contamination level • Sampling reduction cost • No drain IFPAC 2008 – Baltimore January 29 ,2008
Thank you for your attention ! And welcome to our Booth 402 IFPAC 2008 – Baltimore January 29 ,2008