150 likes | 620 Views
Planmeca ProX. Planmeca ProX. New intraoral X-ray device Optimal images for all diagnostic needs: variable kV and mA Easy and fast to use: pre-programmed quick settings, practical design Digital ready with Planmeca ProSensor. Peferct wokflow with Planmeca Romexis
E N D
Planmeca ProX • New intraoral X-ray device • Optimal images for all diagnostic needs: variable kV and mA • Easy and fast to use: pre-programmed quick settings, practical design • Digital ready with Planmeca ProSensor. Peferct wokflow with Planmeca Romexis • Versatile installation options
Optimal images for all diagnostic needs • Small focal spot 0.4mm • small unsharpness • Optional long cone • small unsharpness • Geometric requirements for good images are met
Reduced radiation Advantages of the constant potential (DC) X-ray generator • Reduced radiation dose by up to 25% when compared to conventional AC generators • Extremely good and uniform image contrast • Absolute reproducibility of images • Improved reliability and prolonged life span of the X-ray tube • The X-ray unit output is not affected by line voltage fluctuations.
Easy and fast to use • Non-symmetric shape • Tube head and cone have a common smooth plane • easy targeting along the smooth surface • close to the patient’s chest in occlusal images
Easy and fast to use • Smooth movements • Drift-free positioning • Robust design • No vibrations • easy, quick and accurate positioning
Easy and fast to use 66 pre-programmed quick settings • modality selection to choose film, imaging plate or sensor • density setting • adult/child selection • periapicals for different teeth • occlusal • bite-wing / endo • Quick setting allow ALWAYS to have right exposure values for individual cases
Easy and fast to use • hand held control panel • remote exposure station
Digital ready with Planmeca ProSensor • Integrated magnetic connector for digital Planmeca ProSensor intraoral sensors • The Planmeca ProSensor interconnection cable is routed inside the X-ray unit arm, which results in a clear and clean working area with no interfering cables. • The imaging parameters (kV, mA, exposure time) are transferred to the imaging software to be recorded with the patient's images.
Mounting alternatives • Standard wall mount • Floor column mount • Single stud mount, coming 2012 • Pass-through mount, coming 2012 • Dental unit mount, coming 2012 • Ceiling mount (also with operating light), coming 2012
The End More information: Erkki Hiltunen Product Manager, X-rays tel: +358 20 7795 456 erkki.hiltunen@planmeca.com Mark Niemi Product Manager, X-rays tel: +358 20 7795 743 mark.niemi@planmeca.com 12/2011