An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HOME DYNAPAC F1000T/W Paver Controller System Propel Controller

  2. Propel Controller - Specification Start Up & Calibration Download & Settings • Sauer Danfoss MC50-12 • Integral Digital Signal Processor (DSP) with 256 K Flash memory • Application Development using Plus 1 Guide Software including service tool for function monitoring & controlling • 22 Inputs & 16 Outputs • 9 – 36V DC Power supply monitored internally • 2 CAN 2.0B Ports Click here for detailed spec.

  3. Propel Controller Inputs & Outputs

  4. Propel Controller - Inputs Console Select Switch Gear/Engine Speed Select Switch (0.5V to 4.5 V) Sauer DP200 Multi function Display (Connected Via CAN) Park Brake Switch Joystick/FNR Stick (0.5 V to 4.5 V) Steering Trim (0.5 V to 4.5 V) Max Speed (0.5 V to 4.5 V) LH Console Steering Wheel*** (0.5 V to 4.5 V) **Same Devices are repeated in RH Console *** Steering Wheel replaced by steering position sensor in F1000W

  5. Propel Controller – Inputs contd • Speed Sensor ( Frequency Input) from LH, RH Propel Motor & Generator Motor • Fuel Sending Unit ( Resistance Input)

  6. Propel Controller - Outputs • LH & RH Drive Pump – EDC control (15 to 85 mA) • Generator Pump – EDC Control ( 15 to 85 mA) • LH & RH Propel Motor Displacement Control ( Speed Shift) – Digital 24V • Planetary Gear Box Shift ( Digital 24V) • Console Select Relay output ( Digital 24V) • Automatic function ( Auger Conveyor, Vibration, Levelling system) enable relay (Digital 24V) • Fume Extractor Contactor enable output ( Digital 24V) • FWA Valve enable ( Digital 24 V) – F1000W only

  7. Propel System Control Layout Propel Controller • Joystick • Gear Selector • Speed Dial • Steering Wheel • Steering Trim • Dual path drive control system • Signal to LH & RH Propel Pump • Signal to propel Motor • Signal to Gear selector valve Speed Sensor Feed back Track Motor & Gear Box

  8. Propel System Control Layout Speed Sensor Feed Back Commanded Input Commanded Input Speed Sensor Feed back

  9. Propel System Layout Warnings/Active Faults • Propel Controller is built with the smartness of identifying any inputs or outputs connectivity or operator error while operating the Paver or any unwanted/un intended hazards. • If anything that happens abnormal then the propel controller will send a Warning Signal or Active fault to the Multifunction display (DP200) depending on the severity of the issue. • Warning Signal – This will be displayed if there is an un intended operation of the Paver & the signal will be no longer displayed once the paver function is operated correctly. • Example : Trying to give propel command when the park brake is engaged. • Active Fault – This will be displayed if there is improper wiring (Open or short circuit) or if the parameter’s goes out of limit than expected. This requires re-powering the entire machine after correcting the issue. The fault may continue to show up even after the re – powering if the issue still exists. • Example : Open/Short circuit on the Inputs/outputs. • Machine is not moving even after the proper command is given the pumps & motors. • Power supply issues • Improper wiring/grounding methods etc

  10. Propel System Layout Warnings/Active Faults • List of Warning Codes Built In

  11. Generator System Layout Propel Controller • Closed loop speed Control ( Frequency 60 Hz +/- 5% ) • EDC Control of S90 Generator Pump • Hyd motor to run @ 1800 rpm regardless of Engine/Generator load • PID (Proportional, Integral & derivative) Loop used • Signal to Gen Pump after 15 Sec of Engine Turn On • 15 to 85 mA Signal to maintain 1800 rpm of Motor regardless of engine speed & Gen load Speed Sensor Feed back Generator Motor

  12. Other Systems • Automatic Function Turn on ( R7 Relay) • To allow the Automatic functions ( Screed Vibration, Auger conveyor system, Topcon Leveling system, Screed Float ) to activate only forward moving • Console Select Relay Activate • To active the LH & RH consoles based on the operator request based on pre determined conditions. • Fume Extractor Contactor enable • This o/p enables the fume extractor contactor with a delay of 5 sec after generator kicks on • FWA Valve Enable • To activate the FWA function only when the machine is moving forward & in 1st & 2nd gears only.

  13. HOME Driven by innovation – committed to customer performance