Humidity Sensor ALH Series (ALH-3EG)

X1. X1. N. X2. C. H. O. X2. N. X1. X1. N. X2. C. H. X2. C. H. -. A. +. X1. N. Specifications. Humidity Sensor ALH Series (ALH-3EG). High Quality Low Cost. Specification (ALH Series). ALH-3EG. ALH Series Important Features High resistance to a water

tory
Download Presentation

Humidity Sensor ALH Series (ALH-3EG)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. X1 X1 N X2 C H O X2 N X1 X1 N X2 C H X2 C H - A + X1 N Specifications Humidity SensorALH Series (ALH-3EG) High Quality Low Cost

  2. Specification (ALH Series) ALH-3EG • ALH Series Important Features • High resistance to a water • Low cost performance • Long term stability • Very low hysteresis • Fast response time • Small dimensions • Wide humidity operating range • Typical Applications • Air-conditioner • Humidifier-Dehumidifier • Automobile • Clean room • Food products • Humidity controller & Transmitter Electrical Characteristics ★ ±2%RH (at 25℃,60%RH) is available High Quality Low Cost

  3. Specification (ALH Series) ALH-3EG Mechanical Test Lead Bend StrengthThe humidity sensor is kept in the vertical direction and the leads should be bent 1 cycle in the direction of 90 degree of load applied 250g. No change in appearance or performance is allowed. • Lead strength testA loadof 1kg is applied to each lead in the vertical plane against the surface of the sensor for • 60 ±1 seconds. • No change in appearance or performance is allowed. • Drop TestHumidity sensor is dropped on to a wooden surface from a height of 1 m three times. • No change in appearance or performance is allowed. Reliability Test High Quality Low Cost

  4. Specification (ALH Series) ALH-3EG ALH-3EG Standard Characteristics ( Unit : Kohm ) ( Condition : at 25 ℃,1VAC,1kHz) High Quality Low Cost

  5. Specification (ALH Series) ALH-3EG ALH-3EG Response Curve (Resistance against Humidity) ( Unit : Kohm ) ( Condition : at,1VAC,1kHz) High Quality Low Cost

  6. 5.00 Polymer film 10.0 Electrode Solder Pad Lead Frame 0.5 13.0 2.54 Specification (ALH Series) ALH-3EG Dimensions (Unit :mm) User Notes • Do not use DC voltage directly to Humidity sensor. • Do not use organic solvents,wipe the surface softly using cotton stick in which • boiling steam has penetrated, when cleaning humidity sensing surface. • Do not expose sensor directly to smoke from cigarettes,steam. • Do not touch the sensing surface with wet hands. High Quality Low Cost