Filter diameters and flow rates Samplers 1 through 4 have 47 mm diameter filters

RUG sampling activities at Fazenda Nossa Senhor a Willy Maenhaut Ghent University (RUG) Institute for Nuclear Sciences Department of Analytical Chemistry Proeftuinstraat 86, B-9000 Gent, Belgium. Filter diameters and flow rates Samplers 1 through 4 have 47 mm diameter filters

travis
Download Presentation

Filter diameters and flow rates Samplers 1 through 4 have 47 mm diameter filters

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. RUG sampling activities at Fazenda Nossa SenhoraWilly MaenhautGhent University (RUG)Institute for Nuclear SciencesDepartment of Analytical ChemistryProeftuinstraat 86, B-9000 Gent, Belgium

  2. Filter diameters and flow rates • Samplers 1 through 4 have 47 mm diameter filters • they operate at a flow rate of 17 Liters per min • MOUDI operates at a flow rate of about 30 Liters per min • SDI operates at a flow rate of 11 Liters per min • HiVol samplers have 102 mm diam. Filters • flow rate: 320 Lpm (Hi flow) and 35 Lpm (Low flow) • Analytical techniques • PM gravimetric analysis for the particulate mass (PM) • INAA instrumental neutron activation analysis (INAA): • 40 elements, from Na upward • PIXE particle-induced X-ray emission spectrometry (PIXE): • over 20 elements, from Na upward • IC ion chromatography • TOT thermal-optical transmission (TOT) instrument for • measuring organic carbon (OC) and elemental carbon (EC) • TOC total organic carbon (TOC) analyser for measuring • water-soluble organic carbon (WSOC) • GC/MS gas chromatography / mass spectrometry

  3. Aerosol collections • from 9 September to 14 November 2002 • 8 samplers operated in parallel • separate day and night samples mostly collected • collection time per sample varied from 12 hours in September • to up to 48 hours in November • 80 collections with each sampler

  4. Contributions to samplings from MPIC and UPR • baking and weighing of aluminum foils for MPIC MOUDI • weighing of filters and collection substrates for UPR • Dekati LPI (DLPI) • SFU samplers