Motor Designs A, B, C, D

Motor Designs A, B, C, D. Cross-Sections of NEMA Motors. Induction Motor Applications. Design B Broadest field of applications Centrifugal pumps, fans, blowers, machine tools Design A Same characteristics as Design B, but with higher breakdown torque

valmai
Download Presentation

Motor Designs A, B, C, D

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Motor Designs A, B, C, D ECE 441

  2. Cross-Sections of NEMA Motors ECE 441

  3. Induction Motor Applications • Design B • Broadest field of applications • Centrifugal pumps, fans, blowers, machine tools • Design A • Same characteristics as Design B, but with higher breakdown torque • Higher starting current limits applications ECE 441

  4. Induction Motor Applications continued • Design C • Higher locked-rotor torque but lower breakdown torque than Design B • Use to drive plunger pumps, vibrating screens, and compressors • Design D • Very high locked-rotor torque and high slip • Used for high-inertia loads such as elevators and hoists ECE 441

  5. Induction Motor Applications continued • Design E • High-efficiency • Drive loads similar to Design B, but with lower locked-rotor, breakdown, and pull-up torque ECE 441

  6. NEMA Tables • Tables 5.1 – 5.7 give values of locked-rotor torque, breakdown torque, and pull-up torque for specific horsepower, frequency, and synchronous speed ratings. ECE 441

  7. Example 5.1 • Determine the values of locked-rotor torque, breakdown torque, and pull-up torque that can be expected from a 3-phase, 10-hp, 460-V, six-pole, NEMA design C motor whose rated speed is 1150 r/m. ECE 441

  8. Solution ECE 441

  9. Locked-Rotor Torque • From Table 5.1, page 171 of the text, the minimum locked-rotor torque of a 10-hp design C motor with a synchronous speed of 1200 r/min should be 225% of full-load torque. ECE 441

  10. Breakdown Torque • From Table 5-3 ECE 441

  11. Pull-up Torque • From Table 5.6, ECE 441

  12. Motor Performance as a function of Machine Parameters, Slip, and Stator Voltage • Use the “complete” equivalent circuit model, including both the rotor and stator. ECE 441

  13. Equivalent Circuit for an Induction Motor with the rotor and stator as separate circuits ECE 441

  14. Equivalent Circuit for an Induction Motor with all parameters referenced to the stator ECE 441

  15. ECE 441

  16. ECE 441

  17. Power, Torque, Speed, Losses, and Efficiency ECE 441

  18. ECE 441

  19. ECE 441

  20. Approximate Equivalent Circuit for an Induction Motor Move the magnetizing branch to the left of resistor R1. ECE 441

  21. Shaping the Torque-speed curve ECE 441

  22. Slip at Which Maximum Torque Occurs Take the derivative of the expression for the developed torque Solve for the value of slip that makes the derivative equal to zero. Slip is directly proportional to the rotor resistance. ECE 441

  23. Slip at Which Maximum Torque Occurs • Applications which require a very high starting torque are designed with enough resistance so that the maximum torque occurs at blocked rotor (s = 1). ECE 441

  24. Slip at Which Maximum Torque Occurs ECE 441

  25. Maximum Torque at maximum torque Independent of Rotor Resistance! ECE 441