An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Damage to equipment in Japan Tetsuya Tominaga Technical Session on Home Networks Geneva, 29/04/2011

  2. Special Resistibility(K.44, K.66) Basic level and Enhanced level of resistibility are described in K.21, The special level is described in K.44 and K.66 Table II.6-1/K.44 – Resistibility and safety requirements of customer premises equipment powered by mains power Technical Session - Home Networks - Geneva

  3. Typical configuration of ONT/HGW • ONT/HGW don’t have external telecom line. • Why the lightning current flows into ONT/HGW? 4 Ether ports 1 Optical fiber port 1 AC adaptor 2 POTS port Fig.1 Typical ONT/HGW Technical Session - Home Networks - Geneva

  4. How many ONT/HGW were damaged? It was not acceptable failure rates for 2kV type ONT/HGW • 6 types of ONT/HGW, total 3 million shipments • ONT/HGW has 2 POTS ports and 4 Ether ports • Observation period 2007-2009 • The resistibility between AC mains to POTS are 7kV – 13 kV Failure rates (%) Resistibility level between POTS ports(kV) Fig.1 Example of Relationship between resistibility and Failure rates Technical Session - Home Networks - Geneva

  5. What port is damaged in ONT/HGW? 70 damaged ONT/HGW were counted the damaged ports Internal POTS port were damaged over 90% Table 1. Example for ratio of failure ports *) POTS is may also include other port failure AC mains – POTS :10kV AC mains port differential : 2kV Between POTS: 1kV Num =70 Technical Session - Home Networks - Geneva

  6. Example of damaged ONT/HGW in the field(1) • Protector elements on POTS ports were damaged TEL1 SLIC TEL2 Damaged Technical Session - Home Networks - Geneva

  7. Example of damaged ONT/HGW in the field(2) • Subscriber Line Card Module and protector elements were damaged • Sometimes RJ11 were damaged and burned Damaged TEL1 TEL2 Damaged Damaged RJ11 Technical Session - Home Networks - Geneva

  8. Lightning surge flows into ONT/HGW • Lightning surge flows port to port • These equipment has AC mains port or individual grounding Ether to Ether 4 Ether ports 1 Optical fiber port POTS to Ether AC port to Ether port POTS to POTS 1 AC adaptor 2 POTS port AC port to POTS port Fig.1 Typical ONT/HGW Technical Session - Home Networks - Geneva

  9. Configuration and current flow (1) • Case 1: Damage occurred between mains power port and internal port • Damage: Home Gate Way & Telephone • Route: AC mains (1)—AC/DC Adaptor—HGW—Telephone—AC mains (2) Technical Session - Home Networks - Geneva

  10. Configuration and current flow(2) • Case 2: Damage occurred between two internal ports of telecom. equipment • Damage: Telecom. Equip 1 (FAX), Home Gate Way & Telecom. Equip 2 (PC) • Route: AC mains (1)–Telecom. Equip 1–HGW–Telecom. Equip 2–SPD–Local PE Technical Session - Home Networks - Geneva

  11. Near Future? / Already Now? Smart appliance connects to Home Gateway. Many kinds of equipment will be connected each other. Optic Fiber Smart Meter SPD:Surge Protective Device Technical Session - Home Networks - Geneva

  12. Bad installation and insufficient resistibility Good installation and Adequate resistibility are needed. Optic Fiber Smart Meter SPD:Surge Protective Device Technical Session - Home Networks - Geneva

  13. Conclusion • Failure rates is over 0.1 %@2kV and 0.01 %@7kV. • Adequate test levels is needed for Internal Port to Internal Port for ONT/HGW Table II.6-1/K.44 – Resistibility and safety requirements of customer premises equipment powered by mains power Technical Session - Home Networks - Geneva