HH Issues - 1. Proposed permeation standard of 2 g/m2/d at 40C, including durability provisions is more stringent than original proposal: as discussed earlier, the data support for this is weak

vera
Download Presentation

HH Issues - 1

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HH Issues - 1 • Proposed permeation standard of 2 g/m2/d at 40C, including durability provisions is more stringent than original proposal: • as discussed earlier, the data support for this is weak • 2 g/m2/d at 40 C is at least two times more stringent as 1 g/m2/d at 65-105 F (original proposal) since the rule of thumb is that a doubling of permeation occurs for roughly every 10C temp rise • test database does not include all durability provisions The Outdoor Power Equipment Institute 341 South Patrick Street • Alexandria, VA 22314 • 703-549-7600 • 703-549-7604 FAX • www.opei.org

  2. HH Issues - 2 • Achieving the proposed permeation standard by 2006 is not feasible as will be discussed in detail subsequently; the OPEI 2007 proposal was based on a tight but realistic set of assumptions • CARB should state explicitly and unequivocally that all compliance provisions are based on CERT fuel only - and not on ethanol-based fuels. The standard will need to be increased to accommodate ethanol fuels. • CARB should consider revising language in Article 8 to deal with product transshipment issues into and out of CA The Outdoor Power Equipment Institute 341 South Patrick Street • Alexandria, VA 22314 • 703-549-7600 • 703-549-7604 FAX • www.opei.org

  3. HH Issues - 3 • Based on earlier discussions, OPEI believes that staff has agreed to the following changes in Article 8 and CP-901: • 2482(i): define HH as engine displacement of less than 80cc • 2482(w): revise the definition of “unibody” tanks per language provided earlier, including DuPont input • 2482(a): change definition of co-ex tanks to have more than just one material (i.e., nylon, EVOH, etc.) • 2489(c)(4)(a): harmonize and simplify labeling language with exhaust regs. The Outdoor Power Equipment Institute 341 South Patrick Street • Alexandria, VA 22314 • 703-549-7600 • 703-549-7604 FAX • www.opei.org

  4. HH Issues - 4 • 2490(d): recognize that the parts list for less than 80cc is tanks only • 2491: have only one warranty statement for exhaust and evap • 2492(a)(7): extend same compliance flexibility proposed provisions for non-HH to HH as well • 2493: expand exemptions to metal and EVOH tanks • CP90, Part I, 1.0: CARB will provide flexibility to “carry-across” test data to other families using similar tanks The Outdoor Power Equipment Institute 341 South Patrick Street • Alexandria, VA 22314 • 703-549-7600 • 703-549-7604 FAX • www.opei.org

  5. HH Issues - 5 • Also, OPEI believes that CARB will consider the following changes to TP-901: • delete references to SHED in favor of vented enclosure • delete requirement on balance accuracy • adjust thermocouple sensitivity to +/- 1F • rethink humidity requirement during testing • delete requirement for full tank during UV testing • delete requirement for 15 hrs/day sunlight for UV testing • remove requirement for full tank during preconditioning soak • delete requirement for 10 days of permeation testing down to 3 days as long as r2 requirement is met The Outdoor Power Equipment Institute 341 South Patrick Street • Alexandria, VA 22314 • 703-549-7600 • 703-549-7604 FAX • www.opei.org