1.27k likes | 1.44k Views
Multi Beamlett Extraction Experiments and Sector Magnet Field Investigation. Platform DC Power Supply. Platform Ground. 35kV. Pulsed Extract Power Supply. 17kV. -. +. Laboratory Ground. 18kV. Extraction Electrode, Coldbox and Analysing Magnet all Pulsed. -. +. 35keV H - Beam.
E N D
Multi Beamlett Extraction Experiments and Sector Magnet Field Investigation
Platform DC Power Supply Platform Ground 35kV Pulsed Extract Power Supply 17kV - + Laboratory Ground 18kV Extraction Electrode, Coldbox and Analysing Magnet all Pulsed - + 35keV H- Beam Post Extraction Acceleration Gap
mA/cm2 2.5 2.0 1.5 1.0 0.5 0.0 17 kV Extraction Voltage 35 kV Platform Voltage 18 kV Post Acceleration Voltage 47 mA Beam Current 355 mm downstream from ground plane of post acceleration gap
mA/cm2 2.5 2.0 1.5 1.0 0.5 0.0 16 kV Extraction Voltage 35 kV Platform Voltage 19 kV Post Acceleration Voltage 42 mA Beam Current 355 mm downstream from ground plane of post acceleration gap
mA/cm2 2.5 2.0 1.5 1.0 0.5 0.0 15 kV Extraction Voltage 35 kV Platform Voltage 20 kV Post Acceleration Voltage 40 mA Beam Current 355 mm downstream from ground plane of post acceleration gap
mA/cm2 2.5 2.0 1.5 1.0 0.5 0.0 14 kV Extraction Voltage 35 kV Platform Voltage 21 kV Post Acceleration Voltage 38 mA Beam Current 355 mm downstream from ground plane of post acceleration gap
mA/cm2 2.5 2.0 1.5 1.0 0.5 0.0 13 kV Extraction Voltage 35 kV Platform Voltage 22 kV Post Acceleration Voltage 35 mA Beam Current 355 mm downstream from ground plane of post acceleration gap
mA/cm2 2.5 2.0 1.5 1.0 0.5 0.0 12 kV Extraction Voltage 35 kV Platform Voltage 23 kV Post Acceleration Voltage 32 mA Beam Current 355 mm downstream from ground plane of post acceleration gap
mA/cm2 2.5 2.0 1.5 1.0 0.5 0.0 11 kV Extraction Voltage 35 kV Platform Voltage 24 kV Post Acceleration Voltage 28 mA Beam Current 355 mm downstream from ground plane of post acceleration gap
mA/cm2 2.5 2.0 1.5 1.0 0.5 0.0 10 kV Extraction Voltage 35 kV Platform Voltage 25 kV Post Acceleration Voltage 25 mA Beam Current 355 mm downstream from ground plane of post acceleration gap
mA/cm2 2.5 2.0 1.5 1.0 0.5 0.0 9 kV Extraction Voltage 35 kV Platform Voltage 26 kV Post Acceleration Voltage 21 mA Beam Current 355 mm downstream from ground plane of post acceleration gap
mA/cm2 2.5 2.0 1.5 1.0 0.5 0.0 8 kV Extraction Voltage 35 kV Platform Voltage 27 kV Post Acceleration Voltage 17 mA Beam Current 355 mm downstream from ground plane of post acceleration gap
mA/cm2 2.5 2.0 1.5 1.0 0.5 0.0 7 kV Extraction Voltage 35 kV Platform Voltage 28 kV Post Acceleration Voltage 13 mA Beam Current 355 mm downstream from ground plane of post acceleration gap
mA/cm2 2.5 2.0 1.5 1.0 0.5 0.0 6.5 kV Extraction Voltage 35 kV Platform Voltage 28.5 kV Post Acceleration Voltage 12 mA Beam Current 355 mm downstream from ground plane of post acceleration gap
mA/cm2 2.5 2.0 1.5 1.0 0.5 0.0 6 kV Extraction Voltage 35 kV Platform Voltage 29 kV Post Acceleration Voltage 10 mA Beam Current 355 mm downstream from ground plane of post acceleration gap
mA/cm2 2.5 2.0 1.5 1.0 0.5 0.0 5.5 kV Extraction Voltage 35 kV Platform Voltage 28.5 kV Post Acceleration Voltage 9 mA Beam Current 355 mm downstream from ground plane of post acceleration gap
mA/cm2 2.5 2.0 1.5 1.0 0.5 0.0 17 kV Extraction Voltage 35 kV Platform Voltage 18 kV Post Acceleration Voltage 47 mA Beam Current 355 mm downstream from ground plane of post acceleration gap
100 x ‘(mRads) 50 0 -50 -100 -60 -30 0 30 -60 x (mm) The Present Situation 17 kV Extract Potential 47 mA Beam Current 100 50 y ‘(mRads) 0 -50 -100 -60 -30 0 30 -60 y (mm) 0.84 πmm-mRad norm rms 0.92 πmm-mRad norm rms
5 4 3 2 1 Cs Cs H2 Multi Beamlett Extraction Position of Caesium and Hydrogen dispensing holes Hole Index To study beam transport aperture plates with 5 separate 1 mm diameter holes have been constructed.
HOLE 1 HOLE 2 HOLE 3 HOLE 4 HOLE 5 ALL 5 6 kV Extraction Voltage 355 mm downstream from ground plane of post acceleration gap 18 kV Post Acceleration Voltage
HOLE 1 HOLE 2 HOLE 3 HOLE 4 HOLE 5 ALL 5 7 kV Extraction Voltage 355 mm downstream from ground plane of post acceleration gap 18 kV Post Acceleration Voltage
HOLE 1 HOLE 2 HOLE 3 HOLE 4 HOLE 5 ALL 5 8 kV Extraction Voltage 355 mm downstream from ground plane of post acceleration gap 18 kV Post Acceleration Voltage
HOLE 1 HOLE 2 HOLE 3 HOLE 4 HOLE 5 ALL 5 9 kV Extraction Voltage 355 mm downstream from ground plane of post acceleration gap 18 kV Post Acceleration Voltage
HOLE 1 HOLE 2 HOLE 3 HOLE 4 HOLE 5 ALL 5 10 kV Extraction Voltage 355 mm downstream from ground plane of post acceleration gap 18 kV Post Acceleration Voltage
HOLE 1 HOLE 2 HOLE 3 HOLE 4 HOLE 5 ALL 5 11 kV Extraction Voltage 355 mm downstream from ground plane of post acceleration gap 18 kV Post Acceleration Voltage
HOLE 1 HOLE 2 HOLE 3 HOLE 4 HOLE 5 ALL 5 12 kV Extraction Voltage 355 mm downstream from ground plane of post acceleration gap 18 kV Post Acceleration Voltage
HOLE 1 HOLE 2 HOLE 3 HOLE 4 HOLE 5 ALL 5 13 kV Extraction Voltage 355 mm downstream from ground plane of post acceleration gap 18 kV Post Acceleration Voltage
HOLE 1 HOLE 2 HOLE 3 HOLE 4 HOLE 5 ALL 5 14 kV Extraction Voltage 355 mm downstream from ground plane of post acceleration gap 18 kV Post Acceleration Voltage
HOLE 1 HOLE 2 HOLE 3 HOLE 4 HOLE 5 ALL 5 15 kV Extraction Voltage 355 mm downstream from ground plane of post acceleration gap 18 kV Post Acceleration Voltage
HOLE 1 HOLE 2 HOLE 3 HOLE 4 HOLE 5 ALL 5 16 kV Extraction Voltage 355 mm downstream from ground plane of post acceleration gap 18 kV Post Acceleration Voltage
HOLE 1 HOLE 2 HOLE 3 HOLE 4 HOLE 5 ALL 5 17 kV Extraction Voltage 355 mm downstream from ground plane of post acceleration gap 18 kV Post Acceleration Voltage
H2 Cs Cs 5 4 3 2 1 Beam Current Variation with Extraction Voltage
θ r B r = 55 mm B r = 105 mm Mapping the Field H2 Cs Cs 5 4 3 2 1
Angle (Degrees) Magnetic Field
Angle (Degrees) Field Index
H2 Cs Cs 5 4 3 2 1 Sector Magnet Modifications
H2 Cs Cs 5 4 3 2 1 Sector Magnet Modifications
H2 Cs Cs 5 4 3 2 1 Sector Magnet Modifications
Sector Magnet Modifications H2 Cs Cs 5 4 3 2 1
VARY POST ACCELERATION VOLTAGE
HOLE 1 HOLE 2 HOLE 3 HOLE 4 HOLE 5 ALL 5 23 kV Post Acceleration Voltage 355 mm downstream from ground plane of post acceleration gap 7 kV Extraction Voltage
HOLE 1 HOLE 2 HOLE 4 HOLE 5 ALL 5 25 kV Post Acceleration Voltage 355 mm downstream from ground plane of post acceleration gap 7 kV Extraction Voltage
HOLE 1 HOLE 2 HOLE 4 HOLE 5 ALL 5 26 kV Post Acceleration Voltage 355 mm downstream from ground plane of post acceleration gap 7 kV Extraction Voltage
HOLE 1 HOLE 2 HOLE 4 HOLE 5 ALL 5 27 kV Post Acceleration Voltage 355 mm downstream from ground plane of post acceleration gap 7 kV Extraction Voltage
HOLE 1 HOLE 2 HOLE 4 HOLE 5 ALL 5 28 kV Post Acceleration Voltage 355 mm downstream from ground plane of post acceleration gap 7 kV Extraction Voltage