210 likes | 304 Views
IFE TARGET CHAMBER VACUUM PUMPING SYSTEM 11m Radius Case. 1 C. Gentile, 1 C. Priniski, 2 J. Sethian, 1 R. Parsells, 1 S. Langish, 1 L. Ciebiera, 1 W. Blanchard, 1 R. Yager, 1 C. Jun 1 Princeton Plasma Physics Laboratory 2 Naval Research Laboratory
E N D
IFE TARGET CHAMBER VACUUM PUMPING SYSTEM11m Radius Case 1C. Gentile, 1C. Priniski, 2J. Sethian, 1R. Parsells, 1S. Langish, 1L. Ciebiera, 1W. Blanchard, 1R. Yager, 1C. Jun 1 Princeton Plasma Physics Laboratory 2 Naval Research Laboratory 12th HAPL Meeting, Lawrence Livermore National Laboratory June 20-21, 2005
Requirements: Email correspondence .: J. Sethian “11 meter radius IFE Target Chamber”, May 12th, 2005.
Design Parameters: • Employ commercial off-the-shelf (COTS) components to minimize costs. • Employ high efficiency turbo molecular pumps backed by roughing pumps. • Employ components which have good operational history in similar environments. • Develop an accurate cost estimate from vendors; detailed quotes. • Design system to transition to D-T operations with minimal modifications. • Design system to meet base pressure and operation pressure in accordance with 5 Hz operation.
System Specifications: • Target Chamber Size • Inner radius = 11 m • Target chamber volume 5,575,279 liters • Total laser duct volume 150,796 liters • Total volume (with 60 beam ports) 5,726,085 liters • Target Chamber Pressures • Operational base pressure = 0.5 mtorr • Gas load = 141 torr-liters/sec • Total system in-leakage = 1x10-5 torr-liters/sec
Vacuum Pumping System: • Target Chamber Pumping • TMP pumping through (laser port) beam ducts = 60 • TMP’s (Varian-V 6000) = 2 TMP’s /duct • TMPS’s total =120 • TMP backing pumps (Kinney KMBD-2000) = 1/6 TMP’s • Backing pumps total = 20 • Outboard Beam Duct Pumping • TMP’s (Varian-V 2000 HT) = 1/beam port • TMPS’s total =60 • TMP Heat Loading • Gas Load T=1000K–4000K, no operational effect • System Pumpdown • From 760 torr to 0.5 mtorr (initial conditions) 18 hrs
Laser Duct Pumping Continued GIMM Beam Tube "Vacuum" Window HeliflexGaskets K B 10” VAT Valve Turbo-V 2000 HT E