1 / 16

Detector development and physics studies in high energy physics experiments

Shashikant Dugad Department of High Energy Physics Review, 3-9 Jan 2008. Detector development and physics studies in high energy physics experiments. Motivation. DAE-DST Vision meeting (7-8 April 2006) Need for core detector development. Water Cherenkov with WLS Readout.

wayne
Download Presentation

Detector development and physics studies in high energy physics experiments

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Shashikant Dugad Department of High Energy Physics Review, 3-9 Jan 2008 Detector development and physics studies in high energy physics experiments

  2. Motivation • DAE-DST Vision meeting (7-8 April 2006) • Need for core detector development Water Cherenkov with WLS Readout Silicon Photomultiplier GRAPES Muon/HCAL Imaging γ-ray Telescope MACE(BARC) ILC-HCAL INO-ECAL Space experiment? (ISRO) Tracking Detector Muon detector for GRAPES Calorimeter HCAL for GRAPES ECAL for INO? Many Other applications Experimental nuclear physics Imaging

  3. Small gain (~1000) solid state device Cost as high as PMT In-sensitive to magnetic field Occupies small volume Photo Devices PMT APD HPD Large gain (106) Cost prohibitive for large scale requirement Sensitive to magnetic field Occupies large volume Low gain (~100) solid state device Cost not as high as PMT In-sensitive to magnetic field Occupies small volume Silicon Photomultiplier Low cost, high gain, fast timing device

  4. SiPM • APD operated above breakdown voltage • Geiger response mode • Essentially a logical device • converted to photon counting by having large array of such diodes in small area APD SiPM

  5. Geiger region 106 to readout the signal Electrical decoupling E, (V/cm) Doping profile N+ 104 Electric field Drift region Phos ~1017 102 P+ Boron ~1015 0 2 1 Uniformity of the electric field x (um) Topology of SiPM Electric field distribution in epitaxy layer Typical design • A micropixel of SiPM has a drift region at few micron epitaxy layer on low resistive P substrate. • PN junction in epitaxy layer provides a depletion region with high electric field where Geiger mode discharge occurs with incoming photons. • Electrical decoupling of the pixels provided by silicon resistive strips. • Uniformity of the electric field within a pixel by n- guard rings or trench. • All micropixels is connected by common Al strip to readout. • Gain ~106 @ ~50 V working bias • Low electronic noise • -> Noise: Dark rate(~2 Mhz) is originated from thermally produced charge carriers Hye-Young Lee

  6. MIP With SiPM in HO-CMS

  7. SiPM development plan • SiPM characterization facility • In progress at Ooty with help from HCAL-CMS collaboration • Packaging and assembly of the device • In progress with Bharat Electronics Limited (BEL) • Device and Process Simulation, Fabrication • BEL, Banglore • Semiconductor Complex Limited, Chandigarh

  8. SiPM Amplifier MSO Initial Setup for SiPM Study at Ooty

  9. Characterization of CPTA-SiPM

  10. Team • BARC • Chandratre etal. • Expertise in device development • Choudhary etal. • Radiation tests • ISRO • Discussions with Dr. Sreekumar in progress • TIFR • Sudeshna Banerjee, S.R. Dugad, S.K. Gupta, P.K. Mohanty • Jagadeesan, A. Jain, S. Karthikeyan, K. Manjunath ...

  11. Water Cherenkov (WC) Detectors • This technique is in use in detection of muons, electrons etc. (GRAPES Ooty, Kamioka, AUGER …) • WC detector used at Ooty has good timing response but poor uniformity with no directinality • Plans to make WC detector with good uniformity, timing and directionality • If we succeed then it can be used as an alternative to scintillators in large air shower array for measuring electromagnetic component • Muon detector with good angular resolution • Hadron/Electromagnetic Calorimeter for GRAPES/INO

  12. Design • Rectangular tube filled with distilled water doped with popop • Several WLS fibers anchored along the length which carries photons to photo device • Dimension: 50x4.6x4.6 cm3 with 16 WLS fibers

  13. Photoelectron yield of Water Cherenkov Detector

  14. Timing Response

  15. Summary • Plans • Silicon Photomultiplier • Characterization laboratory for SiPM • Develop packaging and assembly line • Fabricate SiPM • Water Cherenkov detector • Optimize the performance • Make prototype tracking detector with PMT/SiPM readout • Expose it to ~GeV electron beam at INDUS-Indore to validate its calorimetric performance

  16. Performance of SiPM • Danilov etal.

More Related