170 likes | 428 Views
Product Presentation C-PTD 180/AIR/QC. Air-cooled Peltier Temperature System. 28.02.2013. Content. Pictures Features and Benefits Specification Performance Measurements Special Features Article Number and Price Configuration Example Applications and Markets Competition Summary.
E N D
Product Presentation C-PTD 180/AIR/QC Air-cooled Peltier Temperature System 28.02.2013
Content • Pictures • Features and Benefits • Specification • Performance • Measurements • Special Features • Article Number and Price • Configuration Example • Applications and Markets • Competition • Summary 28.02.2013
Pictures P-CTD 180/AIR/QC 28.02.2013
Features and Benefits C-PTD 180/AIR/QC • Temperature Range Complete range: 0 °C to 180 °C • Measuring Systems Concentric Cylinder Measuring Systems Disposable Measuring Systems Stirrers and Spindles • Air-cooled Peltier system No counter cooling necessary • Typical Measurements Isothermal temperature tests Temperature ramps Temperature swing tests 28.02.2013
C-PTD 180/AIR/QC - Specification • Temperature range 0 °C to 180 °C • Measuring systems Standard systems, DG42 • Beaker Standard beaker, max. CC39 or DG42 • General Good cleanability • Radiation system for counter cooling • Surrounding conditions • Temperature range 5 °C to 35 °C • Relative humidity, not condensing < 80 % • Altitude Up to 2000 m • Pollution Pollution degree 2 according to EN 61010 • Surrounding Laboratory, indoor us only • Supply • Supply voltage 85 to 265 V • Frequency 50 … 60 Hz • Overvoltage Overvoltage category II according to EN 6100 28.02.2013
Technical Specification – Heating Rates Comparison Peltier / Liquid Temperature Control Heating rate (Peltier): 8.0 °C/min Heating rate (Liquid): 5.0 °C/min 28.02.2013
Technical Specification – Cooling Rates Comparison Peltier / Liquid Temperature Control Cooling rate (Peltier): 4.0 °C/min Cooling rate (Liquid): 0.5 °C/min 28.02.2013
Examples - Heating StableConditions after approx. 15 min 28.02.2013
Examples - Cooling StableConditions after approx. 15 min 28.02.2013
Special Features • Wide temperature range: 0 °C to 180 °C • Air cooled Peltier temperature system • Rapid changes in temperature • No external controller necessary • No counter cooling by an external circulator • Easy to install • Space saving design • Noise reduced 28.02.2013
Article Number Item-no.108642 C-PTD 180/AIR/QC Peltier Temp. Control System Temp. range: 0 to 180 °C 28.02.2013
Standard Configuration • Basic Instrument RheolabQC • 108642 C-PTD 180/AIR/QC • 20654 Disposable Measuring System CC39/D/QC-LTD • 20655 Disposable Measuring System CC27/D/QC-LTD • Option: • 18385 Software Rheoplus 28.02.2013
Applications & Markets Coatings: Flow Curve, Yield Point, 3ITT (Thixotropy) Food: Flow Curve, Yield Point, Temperature Test, 3ITT (Thixotropy) Building Materials: Flow Curve, Yield Point, 3ITT (Thixotropy) 28.02.2013
Applications & Markets Adhesives: Flow Curve, 3ITT (Thixotropy), Temperature Test Cosmetics: Flow Curve, Yield Point, Temperature Swing Test Pharma:Flow Curve, Yield Point, Temperature Swing Test Soft Gels: Yield Point, 3ITT (Thixotropy) Lubricants, Oils: Flow Curve, Temperature Test Asphalt: Flow Curve, Temperature Test 28.02.2013
Summary C-PTD 180/AIR/QC is the new Peltier temperature system for the RheolabQC with: • Wide temperature range: 0 °C to 180 °C • Air cooled Peltier temperature system • Cheaper configuration compared with the liquid temp. control systems • Compact design, no counter cooling by an external circulator • Easy handling • Small footprint • Noise reduced compared to a fluid circulator • Low power consumption • Fast and accurate temperature setting • no thermal fluids/oil necessary • Firmware V1.26 for the RheolabQC required 28.02.2013