1 / 17

Calculating the Cell Potential

Calculating the Cell Potential The process of calculating the cell potential is simple and involves calculation of the potential of each electrode separately, then the overall cell potential can be determined from the simple equation: E cell = E cathode - E anode

wren
Download Presentation

Calculating the Cell Potential

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Calculating the Cell Potential The process of calculating the cell potential is simple and involves calculation of the potential of each electrode separately, then the overall cell potential can be determined from the simple equation: Ecell = Ecathode - Eanode Sometimes, this relation is written as: Ecell = Eright – Eleft This is true since the convention is to place the cathode to the right of the cell while the anode is placed to the left of the cell

  2. For example, look at the following cell representation: Cu(s)| CuSO4(0.100 M) || ZnCl2 (0.200 M)|Zn(s) This cell is read as follows: a copper electrode is immersed in a 0.100 M CuSO4 solution (this is the first half-cell, anode), 0.200 M ZnCl2 solution in which a Zn(s) electrode is immersed (this is the second half-cell, cathode). If the Ecell is a positive value, the reaction is spontaneous and if the value is negative, the reaction is nonspontaneous in the direction written and will be spontaneous in the reverse direction.

  3. Effect of Concentration on Electrode Potential The IUPAC convention for writing half-cell reactions is to represent the process as a reduction. The more positive half-cell reaction is the oxidizing agent (where the anode is) and the less positive half-cell reaction is the reducing agent (where the cathode is). The relationship between the concentration and the electrode potential for a half-cell reaction is represented by Nernst equation where for the half-cell reaction we have: aA + bB + ne D cC + dD Eo = x V

  4. The Nernst equation can be written as: E = Eo – (RT/nF) ln {[C]c[D]d/[A]a[B]b} Where, R is the molar gas constant (R = 8.314 J mol-1 K-1), T is the absolute temperature in Kelvin ( T = oC + 273) and F is the Faraday constant ( F = 96485 Coulomb.eq-1) and n is the number of electrons per mole. One may write after substitution: E = Eo – (0.0592/n) log {[C]c[D]d/[A]a[B]b}

  5. Example Calculate the electrode potential for the half-cell below if the solution contains 0.100 M Cu2+. The half-cell reaction is: Cu2+ + 2e D Cu (s) Eo = 0.521 V Solution E = Eo – (0.0592/n) log [Cu(s)]/[Cu2+] E = 0.521 – (0.0592/2) log 1/0.100 E = 0.491 V

  6. Example Calculate the electrode potential of a half-cell containing 0.100 M KMnO4 and 0.0500 M MnCl2 at pH 1.000. Solution MnO4- + 8 H+ + 5 e D Mn2+ + 4 H2O Eo = 1.51 V E = Eo – (0.0592/n) log [Mn2+]/[MnO4-][H+]8 E = 1.51 – (0.0592/5) log 0.0500/0.100*(0.100)8 E = 1.42 V

  7. Redox Indicators Redox visual indicators are of two types. The first type is called specific while the other type is called nonspecific. An example of a specific indicator is starch where it forms a blue complex with iodine but not with iodide. When iodine is consumed, the blue complex disappears and the solution turns almost white indicating the end point. Another specific indicator is the permanganate ion where it is also called a self indicator. The purple color of the permanganate ion is converted to the colorless Mn2+. Nonspecific redox indicators are very weak oxidants or reductants which have different colors of the oxidized and reduced forms. When all the analyte is consumed in a redox reaction, the first drops of excess titrant will react with the indicator, thus changing its color.

  8. The redox indicator equilibrium can be represented by the equation below: InOX + n e = InRED Eo = x V E = EIno – (0.0592/nIn) log [InRED]/[InOX] The color of the oxidized form can be clearly distinguished when 10 [InRED] = [InOX] and the color of the reduced form can be clearly distinguished when [InRED] = 10 [InOX]. Substituting into the electrode potential equation we get: DEColor Change = EIno+ (0.0592/nIn) Therefore, the color change of the indicator occurs around EoIn and, in fact, very close to it. For a real titration, EoIn should be as close as possible to the electrode potential at the equivalence point, Eep, and should thus be at the potential range of the sharp break of the titration curve

  9. Examples of some redox indicators

  10. Redox Titrations The idea of redox titrations is that the potential of a redox reaction will change as the concentration changes. Therefore, consider the following redox reaction, Fe2+ + Ce4+D Fe3+ + Ce3+ If we titrate Fe2+ with Ce4+, the concentration of Fe2+ will decrease upon addition of Ce4+ and thus the potential of an electrode immersed in a Fe2+ solution will start to change. This means that the potential of the cell will be a function of Fe2+ concentration. Thus, if the volume of Ce4+ added is plotted against the electrode potential, a titration curve will be obtained. See the discussion below.

  11. Titration Curves Oxidation-reduction titrations and titration curves can be followed by measuring the potential of an indicator electrode (e.g. platinum) as compared to a reference electrode (has a fixed constant potential, like Saturated Calomel Electrode, SCE). The potential of the cell measured is: Ecell = Esolution – Ereference electrode

  12. Reference electrode Voltmeter Indicator electrode Semipermeable barrier

  13. Ecell = Esolution – Ereference electrode This means that: Esolution = Ecell + Ereference electrode Assume the process of titration of Fe2+ with Ce4+, we have Fe2+ + Ce4+D Fe3+ + Ce3+ Fe3+ + e D Fe2+ Eo = 0.771 V Ce4+ + e D Ce3+ Eo = 1.70 V We have three cases to consider:

  14. 1. Before equivalence point we have Fe2+/Fe3+ couple and we can use the Nernst equation to calculate the electrode potential where: EFe = EFeo – (0.0592/nFe) log [Fe2+]/[Fe3+] Therefore, we calculate the concentration of Fe2+ and Fe3+ and insert the values in Nernst equation to find the resulting potential of the electrode . We can use the other half reaction to calculate the potential of the cell but it is easier to use the Fe2+/Fe3+ couple since the concentration of Ce4+ is difficult to calculate at this stage. The Nernst equation for such potential calculation is: ECe = ECeo – (0.0592/nCe) log [Ce3+]/[Ce4+]

  15. 2. At the equivalence point, we may combine the two Nernst equations for the two half reactions by adding them up. We get: nFe EFe + nCe ECe = nFe EFeo + nCe ECeo – (0.0592) {log [Fe2+]/[Fe3+] + log [Ce3+]/[Ce4+]} nFe EFe + nCe ECe = nFe EFeo + nCe ECeo – (0.0592) {log [Fe2+] [Ce3+]/[Fe3+] [Ce4+]} But [Fe3+] = [Ce3+] and [Fe2+] = [Ce4+] at equivalence point.

  16. Therefore, the equation simplifies to: nFe EFe + nCe ECe = nFe EFeo + nCe ECeo Also, at equivalence point we have EFe = ECe = Eeq pt, therefore: (nFe + nCe) Eeq pt = nFe EFeo + nCe ECeo The final equation can be written as: Eeq pt = (nFe EFeo + nCe ECeo)/ (nFe + nCe)

  17. 3. After equivalence point, it is easier to calculate the cell potential from the cerium half-cell using the equation: ECe = ECeo – (0.0592/nCe) log [Ce3+]/[Ce4+] It is easier to calculate the Ce3+ and Ce4+ concentrations and it will be difficult to calculate the Fe2+ concentration since it is totally consumed, except for an equilibrium concentration.

More Related