Main problems and sources of down time . JF Comblin 16/12/2013. Availability for the last 6 years. Commissioning during first years. Availability goal is 95%. Problems they have this year: Foil problem: Flickering High repetition rate of impact. Radiations. Thermal variations.
E N D
Main problems and sources of down time JF Comblin 16/12/2013
Availability for the last 6 years • Commissioning during first years. Availability goal is 95%.
Problems they have this year: • Foil problem: Flickering • High repetition rate of impact. • Radiations. • Thermal variations. • No frame. Attached only by the top. • Problems of vacuum in DTL. • External faults: Lots of thunder storms during the summer. • Intervention: • Operators can’t intervene anymore on equipment. • No piquet service. • Best effort. Often there is only 1 person.
Reliability studies: • Reliability Block Diagram in BlockSim application : Identify critical components; improve system performance; plan maintenance and spares; identify vulnerabilities • Preventive Maintenance: • Foil: Every 4-6 weeks. 2 to 6 hours needed to outgas and reconditionning. • Source: Every 4 weeks. 6 to 8 hours to exchange and setup.
Summary Mainly the same problems we have. No piquet. Best effort only (often 1 person). Lots of scheduled maintenance. Study of downtime. Preventive change of source, foils.