20 likes | 142 Views
yearly dose numbers. Au + Au RHIC II luminosity: 7X10 27 1/(cm 2 sec) Weeks per year operation: 25 Fraction of up time: 60% radius: 2.5 cm pion dose: 73 kRad UPC electron dose: 82 kRad Total dose: 155 kRad TLD measured projection: 300 kRad radius: 8 cm pion dose: 7 kRad
E N D
yearly dose numbers • Au + Au • RHIC II luminosity: 7X1027 1/(cm2 sec) • Weeks per year operation: 25 • Fraction of up time: 60% • radius: 2.5 cm • pion dose: 73 kRad • UPC electron dose: 82 kRad • Total dose: 155 kRad • TLD measured projection: 300 kRad • radius: 8 cm • pion dose: 7 kRad • UPC electron dose: 2 kRad • Total dose: 9 kRad • TLD measured projection: 29 kRad
particle count • radius 2.5 cm, RHIC II projection • average pion rate from interactions: 3X105 Hz/(cm2) • average pion count for 1 Yr: 3X1012 1/(cm2) • TLD projection (pion assumption): 12X1012 1/(cm2) • History, 2004 estimate for 2006-2009 operation • average pion rate from interactions: 1.4X104 Hz/(cm2)