1 / 6

Halon Contamination SIB 2009-39 R1

Halon Contamination SIB 2009-39 R1. Deletain Rémi Powerplant Installation & Fuel Systems Certification Directorate Novembre 2011. Halon Contamination. Revision of Safety Information Bulletin on Halon Contamination Applicability:

Download Presentation

Halon Contamination SIB 2009-39 R1

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Halon ContaminationSIB 2009-39 R1 Deletain Rémi Powerplant Installation & Fuel Systems Certification Directorate Novembre 2011

  2. Halon Contamination Revision of Safety Information Bulletin on Halon Contamination Applicability: All persons, companies and organisations procuring Halon 1211 (BCF) and/or Halon 1301 (BTM) for use in aircraft fire extinguishers, or for use in fire extinguishers on ground, i.e. on airfields and airports. 12/11/2014 IASFPWG – Atlantic City - November 2011 2

  3. Halon Contamination Description: In 2009, the CAA UK informed EASA that a supplier of Halon 1211 and Halon 1301 had been deliberately falsifying sample test reports, in order to sell contaminated Halon. Halon 1211 (BCF) is used in handheld fire extinguishers, , usually fitted or stowed in aircraft cabins and some built in engine/auxiliary power units (APU) systems, while Halon 1301 (BTM) is used mainly in fire extinguishing systems for aircraft engines, APU and aircraft cargo compartments. This has resulted in the issuance of several EASA Airworthiness Directives (ADs), requiring many handheld Halon 1211 fire extinguishers to be removed from service. However, no ADs have been considered necessary for engine/APU systems. 12/11/2014 IASFPWG – Atlantic City - November 2011 3

  4. Halon Contamination The following ADs remain valid at the time of issuance of this SIB: AD 2009-0251-E dated 25 November 2009, AD 2009-0278 dated 22 December 2009, AD 2009-0262R1 dated 27 January 2010, AD 2010-0012 dated 05 February 2010, AD 2009-0277R1 dated 05 February 2010, AD 2010-0061 dated 31 March 2010, AD 2010-0062R1 dated 17 May 2010. In accordance with the Montreal Protocol, new Halon production has now been prohibited for several years. Therefore, the vast majority of Halon now available comes from recycling. During the collection of Halon for recycling there are opportunities for contamination to occur. 12/11/2014 IASFPWG – Atlantic City - November 2011 4

  5. Halon Contamination Recommendations: Organizations that are involved in either the production of new equipment containing Halon for aviation use, or the overhaul of aviation equipment and re-filling with Halon, are reminded of the need to perform an independent check for conformity to the appropriate standard. If in doubt, check with the equipment manufacturer regarding the appropriate standard. This recommendation is applicable for all types of Halon, e.g. 1211, 1301, 2402 and any blend of these. It is insufficient to put reliance for Halon purity only on documentation provided by the seller of the Halon. SIB at AD Dpt publication level (status at Nov.2011) 12/11/2014 IASFPWG – Atlantic City - November 2011 5