100 likes | 247 Views
CIM Test Development Process. John Simmins Weekly Status and Planning Meeting 4/12/2011. Agenda. Progress since last meeting Issues, opportunities and risks arising during the previous week Verify progress against stakeholder expectations General issues discussion
E N D
CIM Test Development Process John Simmins Weekly Status and Planning Meeting4/12/2011
Agenda Progress since last meeting Issues, opportunities and risks arising during the previous week Verify progress against stakeholder expectations General issues discussion Action items for individuals Expected work output during next week
Progress Since Last Call Sample vender package for outage test procedure Single file with all data needed Designed for venders to participate in dry run Specific test steps for each system under test OMS MDMS Head End Still needed Vetted sample outage message Instructions to create outage Test system login
Progress Since Last Call Sample / Instance example Outage message created Issues noted Shawn Hu from eXtensible created outage message Discuss later in briefing
Instance Sample Outage Message Header —Shawn Hu <?xml version="1.0" encoding="UTF-8"?> <CreatedEndDeviceEvents xsi:schemaLocation="http://www.iec.ch/TC57/2010/EndDeviceEventsMessage EndDeviceEventsMessage.xsd" xmlns="http://www.iec.ch/TC57/2010/EndDeviceEventsMessage" xmlns:obj="http://iec.ch/TC57/2010/EndDeviceEvents#" xmlns:msg="http://www.iec.ch/TC57/2010/schema/message" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"> <Header> <msg:Verb>created</msg:Verb> <msg:Noun>EndDeviceEvents</msg:Noun> <msg:Context>TESTING</msg:Context> <msg:Timestamp>2011-04-12T10:00:00Z</msg:Timestamp> <msg:Source>HE-001</msg:Source> <msg:ReplyAddress>Not Applied</msg:ReplyAddress> <msg:AckRequired>true</msg:AckRequired> <msg:MessageID>ABC-123</msg:MessageID> <msg:CorrelationID></msg:CorrelationID> <msg:Comment>created end device events for testing</msg:Comment> </Header>
Instance Sample Outage Message Payload —Shawn Hu <Payload> <obj:EndDeviceEvents> <obj:EndDeviceEvent> <obj:createdDateTime>2011-04-12T09:30:30Z</obj:createdDateTime> <obj:reason>Electric Meter Power Out</obj:reason> <obj:Assets> <obj:mRID>3dc53ee5-777e-50b4-8699-a1c224f45f3d</obj:mRID> <obj:Names> <obj:name>Meter23253</obj:name> </obj:Names> </obj:Assets> <obj:EndDeviceEventType ref="3.26.0.85"></obj:EndDeviceEventType> <obj:status> <obj:dateTime>2011-04-12T08:35:47Z</obj:dateTime> <obj:value>Electric meter power out</obj:value> </obj:status> </obj:EndDeviceEvent> </obj:EndDeviceEvents> </Payload>
Outage Message Plan to move forward • Start with Instance/Sample message • Describe content/format as required • Include in vender package • Review and vet message with venders as required • OMS • MDMS • Head End • Meter
Expected Work Output During the Next Week Meeting with Consumers (Mark) and EnerNex (Kay) Consumer server login process Continue Sample Messages Sample message from IOP would be helpful Process to connect multiple test sites needs to be dry run