1 / 19

Efficient Management for Building Automation

Efficient Management for Building Automation. Market Trend. Market Distribution. Total Market Share : USD24.4 billion Top 3 control vendors occupy 83% of the market share (JCI>Siemens>Honeywell) The Business for HVAC : 55.1% of BA market: USD13.4 billion

yetty
Download Presentation

Efficient Management for Building Automation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Efficient Management for Building Automation

  2. Market Trend

  3. Market Distribution • Total Market Share : USD24.4 billion • Top 3 control vendors occupy 83% of the market share (JCI>Siemens>Honeywell) • The Business for HVAC : • 55.1% of BA market: USD13.4 billion • USD2 billion of HVAC market taken up by other vendors (17%)

  4. FAB of BAS System • Supporting both BACnet MS/TP & Modbus/RTU protocols • Built-in over 30 sets of BA functional block (KW SoftLoginc in BAS-2000 Controller) • Digital Output with Manual Switch ON/AUTO/OFF for Emergency Operation (BAS-2000 Controller) • Supporting Functional Block & Ladder Diagram in the same time (KW SoftLogic) • Supporting RS-232/485 Communication • 24VAC/18~30VDC power requirement for widely range power supply system (BAS-2000 Controller)

  5. Management for Building Equipments

  6. SoftLogic Completed Product Lines WebLink WebOIT BAS-2000 Hub/Switch Opened Networking Advantech Building Automation Solution

  7. Solution in Security Management

  8. Solution in CCTV Management

  9. BAS Operator Interface Introduction • WebOIT-1560 • 15” Touch panel computer with A-Studio • 15" XGA TFT LCD • Supports Windows 9x/NT/2000/CE • Supports PC/104+ expansion slot • NEMA4/IP65 compliant 15” • WebOIT-1260 • 12” Touch panel computer with A-Studio • 12.1" SVGA TFT LCD • Supports Windows 9x/NT/2000/CE • Anti-vibration HDD kits • NEMA4/IP65 compliant 12” • WebOIT-650 • 6” Touch panel computer with A-Studio • 6.4" VGA TFT LCD • Intel Pentium 166 MMX CPU • One 16-bit PC/104 expansion slot • NEMA4/IP65 compliant 6” • WebOIT-60S • 5.7” Touch panel computer with A-Studio • 5.7" QVGA STN LCD • SamsungARM9 CPU • Built-in Windows CE OS • NEMA4/IP65 compliant 5.7”

  10. BAS Gateway Introduction

  11. BAS-2000 Product Introduction Controller Expansion I/O • BAS-2014 • 14 channel I/O Expansion Module • BAS-2020 • 20 channel I/O Expansion Module • BAS-2514 • 14 channel Softlogic Digital Controller • BAS-2520 • 20 channel Softlogic Digital Controller

  12. Features of SoftLogic Digital Controller - BAS-2520/2514 • Supports max. 80 I/O capability/controller • 2500 Vdc isolation in COM Port • Supports Modbus/RTU , BACNet MS/TP communication protocol • Supports Ladder Diagram (LD), Functional Block (FB) , Sequential Flow Chart (SFC) • Built-in HVAC control library • 24VAC +- 10% power supply

  13. I/O Expansion Modules Specification • Analog Input type: • 2,3 wired Pt-100, Pt-1000 • 3K, 10K Thermistor • 0 to 10V, 4 ~ 20 mA signal • A/D resolution: 12-bit • Selectable input type by Software • Digital Input type: • Dry/Wet contact with LED indicator • Support Counter Function • Analog output: • 0 ~ 10Vdc or 4 ~ 20mA output • A/D resolution: 8-bit • Selectable input type by Software • Digital output: • Relay output : AC240VAC@ 3A, with LED indicator

  14. BAS Control Software FBD LD SoftLogic • Programming Package - IEC61131 Programming package - 32-bit Real Time User Interface - Simulation/Debug Tool MULTIPROG Supervisory Station Free Provide BA Functional Blocks • Real-time Engine • Real-time Multi-tasking Control Engine • User’s Control Program PROCONOS BAS-2000

  15. BAS Functional Block Libraries • Stage Cooling Control • Time proportional PID control with cooling action • Modulating Cooling Control • Modulating PID control with cooling action • Staged Heating Control • Time proportional PID control with heating action • Modulating Heating Control • Modulating PID control with heating action • Schedule • Scheduling Start/Stop control for HVAC equipment. There are 4 pairs of start/stop time setting in one day. Days/Weeks multiple schedule setting • Optimum Start/Optimum Stop • The multiple parallel installed equipments (chillers, pumps …..) can be controlled to automatically start/stop sequentially for saving the energy and keeping the system stability. • Economizer Control • Enthalpy Calculation • Single Speed Fan Control • VFD Fan Control • Return Fan Tracking • Sliding Window Smoothing • CFM Calculation • Device Supervisor Control “Super” • Alarm • Minimum Timer • More…

  16. BAS HMI Software Web-based SCADA SoftwareAdvantech Studio R6.0Main Features:- Provides on-line configuration and remote management capabilities - Imports and exports recipes, reports and real-time data in XML format - Over 20 pre-built I/O drivers for most applications (for Windows CE) (140 I/O drivers for Windows NT - New Alarm and Event Object- Expanded ActiveX Object Support- Remote Debug Tool WebOIT WebLink

  17. Thank You!

More Related