1 / 62

CMS ECAL calibration and Search for the Standard Model H  gg Yong Yang, Caltech

CMS ECAL calibration and Search for the Standard Model H  gg Yong Yang, Caltech Fermilab RA candidate talk, Nov 27 2012. Introduction. A great success of the Standard Model so far. Higgs mechanism, giving mass to W, Z boson and fermions. Predicted a Higgs boson, the last particle

yosefu
Download Presentation

CMS ECAL calibration and Search for the Standard Model H  gg Yong Yang, Caltech

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CMS ECAL calibration and Search for the Standard Model Hgg Yong Yang, Caltech Fermilab RA candidate talk, Nov 27 2012

  2. Introduction • A great success of the Standard Model so far. • Higgs mechanism, giving mass to W, Z boson and fermions. • Predicted a Higgs boson, the last particle to be firmly confirmed. • Both CMS and ATLAS experiments observed a new particle around 125 GeV, statistically consistent with SM Higgs boson.

  3. Large Hadron Collider • Proton-proton collider at √s = 7, 8 TeV (design 14 TeV) • Built to answer most fundamental open questions in physics: • Interactions and forces, deep structure of space and time • Higgs mechanism in Standard model, new physics. • Excellent performance in first 2 years of running, peak instantaneous luminosity: • 2011, 4 x 1033 cm-2s-1 • 2012, 7.6 x 1033 cm-2s-1 • Design, 1034 cm-2s-1 27 km circumference 50-175 m underground

  4. Analyzed data Expected 25 fb-1 by end of pp running this year 2011’s data used in majority of this talk. Latest Hggresults upto July 2012

  5. Pileups • pileups: simultaneous inelastic interactions • multiple vertices: challenge for Hgg • pileup energies added into a cone around the object:  less “isolated”. g Vertex Isolation energy energy from pileup g

  6. Compact Muon Solenoid • Modular design  Pre-assembled • Powerful 3.8 Tesla magnets  Tracking • Crystal ECAL  high resolution • Hermetic calorimeter  Jet and missing ET • Muon system (tracker + muon detectors)  resolution <10% at TeV P PT q z axis (beam line) x-y plane ,f in x-y plane

  7. Higgs boson production at LHC • Higgs boson production modes at the LHC: Cross section [pb] @ 7TeV Gluon-gluon fusion Vector Boson fusion Uncertainty ~15% top-top fusion Higgs bremsstrahlung • Cross Section @ 7 / 8 / 14 TeV @ 125 GeV: 17.5 / 22.3 / 57.0 pb

  8. Hgg decay Uncertainty: input parameters + missing high orders • In the mass rang of interest, from 110 to 150 GeV, small branching ratio ~ 0.2%. • However, competitive sensitivity due to the narrow resonance.

  9. Challenge of Hgg searches • Simple final states: two high pT photons. • Simple discriminating variable: invariant mass of two photons. • Resonance on top of large background. • S/B at 125GeV ~ 1/20. • Analysis is all about the mass resolution: The main challenge: photon energy resolution (measured in ECAL) Signal x 10.

  10. CMS ECAL: 76K Crystals EndCap Barrel Crystals Test beam SuperModule • Homogeneous, compact, and fine grain PWO4 crystal calorimeter • Barrel (|h|<1.5): 61,200 PWO4 crystals + two endcaps ( 1.5<|h|<3, 2x7324 crystals). • Advantage: Intrinsic energy resolution (0.5% for E>100 GeV) • Challenges: achieving this goal in-situ.

  11. ECAL energy measurement CMS measures electron/photon energy as One crystal (channel) • ADCi : single channel amplitude • G: global ECAL energy scale from amplitude to energy. • ci: intercalibration constant for each channel. • LCi: time-dependent correction from laser monitoring system. • f(e/g): particle (object level) energy correction.

  12. Why challenging? • In real CMS detector of ECAL • Response non-uniformity, 15%-25% channel-to-channel variation. • Channel-to-channel Intercalibration • Crystals suffers from dose rate dependent radiation damages, resulting in transparency loss (beam on) and recovery (beam off) • Laser monitoring and correction • Material in front of ECAL, gaps between crystals, shower containment, pileup. • Object level (cluster) energy correction

  13. ECAL energy inter-calibration • Precalibration using test beam, cosmic rays, radiation source prior to installation to precision 0.5% for 20% barrel crystals, and to 1- few % for the rest. • CMS in-situ strategies to equalize the channel-to-channel response variations. e: E/p π0,gg f-symmetry

  14. π0,gg calibration • Principle: use invariant mass of two photons to equalize the energy responses of each crystal. • Main challenges: • To collect enough π0 decays (barrel: 3000 π0 / crystal) to repeat intercalibration every few weeks. Need a dedicated calibration trigger. • Significant extrapolation in energy from calibration sample to Higgs sample. Need explicit validation of calibration performance at high energy. Intercalibration different channels E π0,gg (2-10 GeV) Hgg (50-300 GeV)

  15. π0,gg calibration trigger Data after L1 Triggers Calibration Dedicated online farm ~7 kHz ~50 kHz ~2 ms / event 4-6 MB /s • Main Problem: high output rate required • Saturates HLT processing and output bandwidth (total standard HLT output rate ~300Hz) • Solution: • Restrict to localized ECAL crystal-level information near L1 EG seeds . • Simple selections: pT(g)>1.0 GeV, E4/E9>0.83. • Final selected π0 candidate reduces output to only 20-30 crystals per event

  16. Online selections • Simple selections on pT(g) and pT(gg) , shower shape and isolation (optimized to reject conversion) • only ECAL local-variables used.

  17. Intercalibration method • Iterative method is used to derive the intercalibration constant. (L3 method, see backup) • Adjust the constant step-by-step till it converges channel 1 channel 1 channel 1 channel 2 channel 2 channel 2 channel N channel N channel N Step0 (precalibration) Step1 … Step final Note that N is large (61k for barrel, 15k for endcaps) • CPU consumption is significant.

  18. Improve calibration procedure Module gaps • Cluster containment has dependence on h and j • This dependence introduces energy measurement bias • Correcting for these biases improves the calibration precision by a factor of two.

  19. Intercalibration result (example) cπ0 for each channel • i  crystal index, π0 calibration constant is a correction for precalibration (or the current calibration) • In some supermodules, less corrections  better precalibrated • white areas  dead channels • 3 best precalibrated supemodules used as the reference to study the π0 calibration precision. One supermodule ( 85 x 20 crystals)

  20. Calibration precision (2011) • The single-crystal calibration precision is dominated by π0() method for |h|<2.0 • The region of |h|<1.0 calibrated to 0.5% and is the most important region for Hggsearch

  21. Laser monitoring • Response drops due to transmission loss caused by radiation damage. • Continuous laser monitoring and correction: one measurement of all crystals per 20 minutes.

  22. Laser-monitoring correction • Average signal loss of 2.5% in the barrel, and 10% in the endcaps • After correction, the energy scale (E/p) is stable with 0.1% and 0.5% for barrel and endcaps.

  23. Validation of in-situ calibration Ze+e- • In-situ intercalibration and laser corrections are validated at high energy using Ze+e- data. • Significant improvement on the ECAL energy resolution over precalibrations.

  24. Impact on Hgg search 95% CL limits on s/sSM Precalibration Precalibration + Laser correction In-situ calibration + Laser correction • 38% improvement on the search sensitivity in terms of the exclusion limit due to in-situ intercalibration and laser monitoring correction.

  25. Photon energy correction Ze+e- • The raw clustered energy has dependencies on many factors, for example: crystal gaps, tracker material, pileup • These non-uniformities degrades resolution • CMS standard correction, correcting dependence on a few variables one after another, improves the performance but is sub-optimal.

  26. Multivariate-based correction • The non-uniformities in response, and correlations among dependent variables can be very complicated. • Therefore a multivariate regression technique significantly improves the energy correction.

  27. Regression analysis • A general machine learning technique: • generates a map from a list of input variables to some output • Map is optimized for some particular goal • In our case we optimize for the target Etrue/Ereco • Important to choose well simulated input variables • Otherwise performance in data may degrade Multidimensional minimization problem

  28. Improve Hggsearch sensitivity • Resolution improvement of the MVA-based correction is validated with Ze+e- data. • Absolute scale is also more correct. • 14% improvement on the Hggsearch sensitivity.

  29. Validation of energy resolution • The Hgg photon energy resolution are modeled from MC simulation, and thus needs to be validated with data. • Comparison of the Ze+e- mass resolution between data and MC leads to correction (smearing) of the energy in simulation. • Maximum likelihood fit r9 = E3x3/Ecluster

  30. Photon identification • Large reducible g+jet, jet+jet backgrounds are reduced by cutting on a few variables: • Isolation rAeff is for “pileup” subtraction. • H/E: Hadronic energy (HCAL) / photon energy (ECAL). almost all photon energies are deposited in ECAL only ( 25 radiation length). • Transverse shape of electromagnetic shower. (narrow for real g, wider for fake g) π0 (misidentified asg) π,k.. g

  31. Example N-1 distributions • Selection cuts are separately tuned for photons in 4 “categories”: Barrel or endcaps + r9>0.94 or r9<0.94. • Difference in selection efficiency due to disagreement between data and MC is corrected using Z e+e-.

  32. Event classification • Search sensitivity is improved by splitting all events into different classes according to mass resolution and signal-over-background. Best Resolution Best S/B

  33. Hgg parameterized model • Signal models: 1-3 Gaussians, depending on the category, to well describe both the core and tail of the distributions. • Models separately built for events with or without a correct vertex, in each event category. • Limited mass points simulated. Interpolation for other mass points (right plot).

  34. Background fit on data • Background fit for first two event categories and the expected signal Hgg distribution at 120 GeV. • Use the functional form (5th order bernstein polynomial) that minimizes the bias with respect to a set of possible functional forms (backup). • conservative estimate of the sensitivity

  35. Background fit on data (II) • Background fit for 3rd and 4th event categories.

  36. Background fit on data (III) The excess • Background fit for di-jet (left, 2nd order Bernstein polynomial) and combined categories.

  37. Systematic uncertainties Varying resolution Varying scale • H gg signal shape (sum of Gaussians) is affected by the imprecisely known energy resolution and scale, measured with Ze+e- . • Signal yield is affected by cross section and efficiency uncertainties.

  38. Statistical Interpretation • Statistical analysis gives the quantitative statement of the search results. Two approaches in high energy experiments, differ in the way to interpret “Probability”: • Bayesian: a measure of degree of belief • Frequentist. the frequency of occurrence • CMS and ATLAS have adopted a fully frequentist based method called “CLs-LHC”. • Based on likelihood ratio. • Systematic uncertainties  profiling the nuisance parameters. ( add penalty terms in likelihoods) • Allows for comparison and combination • Exist asymptotic approximation, fast computation.

  39. Exclusion limits • 95% CL upper cross section limit (unit of Standard Model H gg cross section) • SM Higgs boson at given mass is excluded if the observed value is < 1. • Peak indicates event excess over background prediction.

  40. Quantifying the significance • The probability of excess due to background statistical fluctuation. • Local significance: 3.3 standard deviation at 123 GeV • Global significance is 2.0 s, taking into account the unknown mass from 110 to 150 GeV.

  41. Lates results from CMS • Categories combined using S/(S+B). • > 5s significance at 125 GeV. 127-600 GeV is all excluded at high significanceunder Standard Model hypothesis.

  42. Signal strength (s/sSM) 2012 HCP • H gg: 1.6 +/- 0.4 [July 2012] • Production is statistically consistent with a Standard Model Higgs boson 0.88 ± 0.21

  43. Summary • CMS ECAL calibration and correction are crucial to reach the optimal performance, played an important role for the discovery in 2012, in particularly important for Hgg. • π0,gg + f-symmetry + electron in-situ channle-by-channel energy intercalibration. • Laser monitoring and correction for crystal transparency variations. • Object-level multivariate energy correction. • Continued to be very important for ECAL performance and physics at CMS. • Also more challenging at higher luminosities.

  44. backup

  45. Laser injection

  46. ECAL energy clustering • Measured photon energy has dependence on shape of shower • Particularly for converted photons • CMS uses a supercluster algorithm to collect energy from conversion pairs • Converted photons may be identified using the variable r9 = E3x3/Esc

  47. The resolution performance • Central barrel (less material), high r9 (less conversions) • the resolution approaches to 1% at high energies (recall that 0.55% of design) • Main reasons: • imperfect energy correction for conversion, crystal gaps, etc. • imperfect in-situ laser correction • In other categories, worse results due to larger material. Material budget tracker pixel

  48. Hgg vertex identification 1.72 3.10 • The track activities in the best category of Hgg events with two un-converted photons are similar as these pileup events. • A multivariate vertex ID is developed to improve the ID efficiency for low pT Higgs events and larger pileups. • Using , balance and asymmetry of di-photon pT and other tracks, photon conversion significance.

  49. Vertex ID improvement • 10% improvement for events with low pT or larger number of vertices.

  50. Improve Hggsearch sensitivity • 4% improvement on the Hggsearch sensitivity from the improvement on the vertex ID efficiency.