Setup and samples

Setup and samples. Tex2440. Amplifier +shaper. pad detector. 90 Sr/ 241 Am. thermal isolation. cold plate. scintillator. Peltier cooler. water cooled heat sink. trigger signal is possible only for electrons passing through diode.

Download Presentation

Setup and samples

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Setup and samples Tex2440 Amplifier +shaper pad detector 90Sr/241Am thermal isolation cold plate scintillator Peltier cooler water cooled heat sink trigger signal is possible only for electrons passing through diode ~97% purity assures good measurements also at low S/N<1 ~25 ns • DAQ chain (rate to disk ~ 50 Hz) • ORTEC 142B preamplifier • custom made shaping amp. (~25 ns) • Tex 2440 oscilloscope connected to PC • Properties • Peltier cooling up to T=-30oC (stable to 0.1oC) • HV (bias) up to 5 kV • Full computer control (automatic scans) G. Kramberger, Charge collection properties of heavily irradiated expitaxial silicon detectors,RESMDD04, Oct. 10-13, 2004, Firenze