Adaptable Retractor for Total Hip Replacement Surgery

Adaptable Retractor for Total Hip Replacement Surgery. Mechanics of Device . Cost Benefit Analysis. FDA Standards: Device Classification: Class I 510(K) – Exempt, GMP – Not exempt [7] Safety Considerations Material must be biocompatible No sharp edges or small or loose pieces

yul
Download Presentation

Adaptable Retractor for Total Hip Replacement Surgery

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Adaptable Retractor for Total Hip Replacement Surgery Mechanics of Device Cost Benefit Analysis FDA Standards: • Device Classification: Class I • 510(K) – Exempt, GMP – Not exempt [7] Safety Considerations • Material must be biocompatible • No sharp edges or small or loose pieces Sterilization • Autoclave at 273°C for two minutes [8] • 17-4 PH retrains strength up to 315.5°C [6] Safety and Industry Standards Current Surgery Cost • Hip Retractor: $800-$1500 (avg. of $1150) • Surgical Techs: $20/hr * 2 hr surgery time • Three retractors needed in each surgery • Retractors used 50 times a year • Retractor used for 5 years=250 uses/lifetime • Retractor cost per use: $1150/250 uses=$4.60 • Cost/surg.:$4.6*3+2 techs*20/hr*2 hrs=$93.80 Cost with Adaptable Retractor • Hip Retractor: $1400 • 2 retractors,1 surg tech needed in each surgery • Retractor cost per use:$1400/250=$5.60 • Cost/surg.: $5.6*2+1 tech*$20/hr*2 hrs=$51.20 Hospital Savings • $93.80-$51.20=$42.60 savings/surgery • Surgeries with obese patients: 193,000 * 34% =65,620 surgeries/year • Total savings/yr:$42.60*65,620=2.8 mil/year [1]Staff, Mayo Clinic. "Hip Replacement - MayoClinic.com." 2011 [2]"Total Hip Replacement - Your Orthopaedic Connection - AAOS.” [3] Belluck, Pam.” Obesity Rates Hit Plateau in U.S.” NY Times, 2010 [4] NIH, “Hip Replacement,”2010. [5]“Average Wages”. National Bureau of Labor Statistics [6] “Product Data Bulletin: 17-4 PH Stainless Steel.”.2007 [7] FDA,”Product Classification,” 2011. [8] WVR Lead Free Autoclave Instruction Sheets To design a hip retractor that eliminates one retractor during surgery, while increasing the viewing capabilities for the surgeon and that meets the following criteria: Able and strong enough to retract adipose tissue Fit multiple patient sizes and provide a clear view of the surgical site Must be cost efficient • Simple manufacturing • Inexpensive material Ready for use in surgery • Easily attached • Easily sterilized • Total hip replacement surgery (THR) surgery involves removing a diseased hip joint and replacing it with an artificial joint [1] • More than 193,000 total THRs are performed each year in the United States [2] • 34% of the U.S. population is obese [3] • Multiple retractors (3-5) are required in obese patients, thus decreasing the amount of work room A retractor is a surgical instrument available in multiple shapes and sizes that functions to: • Hold back adipose tissue • Increase the incision window Surgical Techs needed to hold retractors • Costs $20/hr * 1-2hr/surgery[4,5] References Computer Modeling Protocol • Use PDE Toolbox in MATLAB to analyze pressure exerted by tissue • Obtain force load on the retractor from tissue pressure • Model stress on the retractor using obtained force loads using Finite Element Method Analysis MATLAB Results • 300 Pa of pressure applied to adaptor piece • 1.5 N of force applied to retractor handle Finite Element Method Analysis Previous team designed a single adjustable retractor • Complex and impractical for manufacturing • Prototype could not be used in surgery Mechanism causing problem: • Physical properties of adipose tissue allow it to wrap around narrow retractors which decreases the range of view of the surgeon Consequences of problem: • Poor surgical field of vision increases cost for additional materials and personnel Final Design Dr. Christie’s Opinion Dimensions of Adaptor Piece • Height: 6 cm • Length: 9 cm • Thickness: 0.3 cm • Top curvature: 4.7 cm • Side curvature: 4.2 cm Design of Adaptor Piece • Increasing curvature along top to retract and envelop fat and skin tissue • Dimensions based on incision size of overweight patient • Curvature based on angle of retraction • Sliding mechanism for simple attachment • Clip holds it in place Material • 17-4 Precipitation Hardening Stainless Steel • Corrosion resistant, easily sterilized [6] • High strength maintained up to 600°F [6] Background Purpose & Design Requirements Trey DeLong, Lacey Gorochow, Brian Rappa, Adam Vandergriff, Sandra Wadeer Advisors: Dave Martinez (Zimmer) and Dr. Michael Christie (Southern Joint Replacement Institute) Department of Biomedical Engineering, Vanderbilt University Problem Statement Figure 5. Stress based on the tissue modeling . Figure 1. Surgeon’s work room obstructed by crowding surgical technicians holding retractors in place Figure 3. Assembly of adaptor piece and retractor • “Best one yet” • System is flexible enough to be used in different types of surgeries • Customized retractor set for specific surgeries will save hospitals money • Instead of having 5,000 instruments on hand, move towards customizing instruments and have only five or six ready for use Figure 4. Adaptor piece. Top: Fully Rounded Bottom: Lofted Figure 6. Maximum Von Misses stress is 20.93 MPa. Figure 7. Maximum displacement is 1.226 mm . • Both retractor and adaptor assigned to stainless steel material properties • Assembly constrained at bottom surface of retractor • Maximum stress of retractor retractor significantly less than ultimate tensile strength of 17-4 PH stainless steel: 1000-1340 MPa [6] • Displacement not significant in adaptor piece or retractor Figure 2. Incision window of THR. Surgical forceps point to obstructing fat that wraps around retractor. Length of incision:12-16 cm, Width: 7-8 cm, Depth: 4-15 cm

More Related