E N D
2. 2 AOS OVEN RANGE
3. 3 TECNICAL DATA
4. 4 TECNICAL DATA
5. 5 AOS OVEN RANGE SAFETY DEVICE:Electric and gas models Safety devices: cooking chamber (CAVITY)
6. 6 AOS OVEN RANGE SAFETY DEVICE:ELECTRIC models Safety devices: steam generator (BOILER)
7. 7 AOS OVEN RANGE SAFETY DEVICE:GAS models Safety devices: steam generator (BOILER)
8. 8 AOS OVEN RANGE:BOILER FILLING SYSTEM
9. 9 AOS OVEN RANGE SAFETY DEVICE:BOILER WATER LEVEL CONTROL
10. 10 AOS OVEN RANGE: CONTROL PANEL
11. 11 AOS OVEN RANGE: CONTROL PANEL LEVEL C
POSSIBILITY TO USE TWO COOKING PHASES
TWO COOKING CYCLES: HOT AIR OR COMBI CYCLE WITH 10 LEVEL OF HUMIDITY CREATED WITH INSTANT STEAM GENERATION (ISG)
UTILITIES
12. Checking Probe Working Temperatures
13. 13 Cooking cycles:
HOT air mode
STEAM mode (212 F)
Low temperature STEAM (< 212 F)
STEAM mode (> 212 F up to 266 F)
COMBI mode
AOS OVEN RANGE: MAIN FUNCTIONS DESCRIPTION
14. 14 AOS OVEN RANGE: MAIN FUNCTIONS DESCRIPTION OVEN SENSORS
Cavity probe
Bypass probe
Boiler probe
Lambda probe (only on lev. A )
Meat probe (act as a timer when cooking with it)
15. 15 AOS OVEN RANGE: MAIN FUNCTIONS DESCRIPTION
HOT air mode:
Cavity probe: controlling display and CAVITY heaters
Bypass probe: controlling steam condenser device
With the humidity set (lev. A ovens), lambda probe is controlling humidity display and cavity flap
16. 16 AOS OVEN RANGE: MAIN FUNCTIONS DESCRIPTION LEVEL A
STEAM mode (212 F)
Cavity probe: controls display
Boiler probe: act as a safety probe
Lambda probe: controls BOILER heaters
Bypass probe: controls steam condenser device
17. 17 LEVEL A
STEAM mode (< 212 F)
Cavity probe: controls display and BOILER heaters
Boiler probe: act as a safety probe
Bypass probe: controls steam condenser device
18. 18 AOS OVEN RANGE: MAIN FUNCTIONS DESCRIPTION LEVEL A
COMBI mode
Cavity probe: controls display and CAVITY heaters
Boiler probe: act as a safety probe
Lambda probe: controls BOILER heaters
Bypass probe: controls steam condenser device
19. 19 AOS OVEN RANGE: MAIN FUNCTIONS DESCRIPTION
20. 20 AOS OVEN RANGE: MAIN FUNCTIONS DESCRIPTION LEVEL C
INSTANT STEAM GENERATION
21. 21 AOS OVEN RANGE: MAIN FUNCTIONS DESCRIPTION
STEAM mode (> 212 F up to 266 F)
It is a combi mode with the above temperature set point and humidity set point of 100%
22. Programming the Default Parameters
23. Access Advanced Program
24. Parameters 2.7
2.8
2.9
3.02
3.10
3.20
25. HECTO PASCAL METER & GASVALVE ADJUSTMENTS AOS pages 15-18
26. Offsets AOS Pages 33-38
AOSQ
27. Error Codes AOSQ Page 8
28. Main Board
29. 29 AOS OVEN RANGE:WIRING DIAGRAM
30. 30 AOS OVEN RANGE:WIRING DIAGRAM
31. 31 AOS OVEN RANGE:CAVITY MOTOR
32. 32 AOS OVEN RANGE:CAVITY MOTOR
33. 33 AOS OVEN RANGE:BOILER HYDRAULIC SYSTEM
34. 34 AOS OVEN RANGE:BOILER HYDRAULIC SYSTEM
35. 35 AOS OVEN RANGE:BOILER DRAIN VALVE
36. 36 AOS OVEN RANGE ELECTRIC:FUNCTIONAL DIAGRAM COMBI MODE
37. 37 AOS OVEN RANGE ELECTRIC:Components
38. 38 AOS OVEN RANGE GAS:FUNCTIONAL DIAGRAM COMBI MODESTEP 1: PCB to Flame control device (FCD)
39. 39 AOS OVEN RANGE GAS:FUNCTIONAL DIAGRAM COMBI MODESTEP 2: FCD to PCB and BLOWER 230V
40. 40 AOS OVEN RANGE GAS:FUNCTIONAL DIAGRAM COMBI MODESTEP 3: PCB to BLOWER PWM at start point
41. 41 AOS OVEN RANGE GAS:FUNCTIONAL DIAGRAM COMBI MODESTEP 4: FCD to GAS VALVE AND IGNITION SPARK
42. 42 AOS OVEN RANGE GAS:FUNCTIONAL DIAGRAM COMBI MODESTEP 5: FCD DETECTION FLAME
43. 43 AOS OVEN RANGE GAS:FUNCTIONAL DIAGRAM COMBI MODE
44. 44 AOS OVEN RANGE GAS:Components
45. 45 AOS OVEN RANGE: CLEANING SYSTEM (LEV. A)
46. 46 AOS OVEN RANGE: CLEANING SYSTEM (LEV. A)
47. 47 AOS OVEN RANGE: CAVITY FLAP FOR HUMIDITY CONTROL
48. 48 AOS OVEN RANGE: CAVITY FLAP FOR HUMIDITY CONTROL
49. 49 AOS OVEN RANGE: COOLING FAN
50. 50 AOS OVEN RANGE: COOLING FAN
51. 51 AOS OVEN RANGE: CAVITY LAMP
52. 52 AOS OVEN RANGE: CAVITY LAMP
53. 53 AOS OVEN RANGE: INSTALLATION Preliminary checks:
Electrical devices
Aeration of the kitchen
Extraction hood or similar device
Water
Gas
Drain
54. 54 AOS OVEN RANGE: INSTALLATION
Select the terminal block according to the power installed for the oven.
Electrical connection:
Electric ovens Gas ovens
55. 55 AOS OVEN RANGE: INSTALLATION Extraction hood or similar device
ELECTRIC OVEN: under extraction hood to avoid steam evacuation
GAS OVEN: under extraction hood to avoid steam evacuation
two type of gas combustion exhaust
56. 56 AOS OVEN RANGE: INSTALLATION Gas connection
The inlet gas pipe is always painted in yellow
57. 57 AOS OVEN RANGE: INSTALLATION Water connection pressure: 22 to 36 psi (150-250 kPa); higher pressure
values result in increased water consumption
58. 58 AOS OVEN RANGE: INSTALLATION How to choose water treatment:
4 tests:
pH
Chloride (ppm) related to corrosion
Conductivity (S/cm)
Hardness (ppm)
Water conductivity: the correct range is
50 2000 S/cm
< 50 S/cm: boiler overfilling
> 2000 S/cm: boiler can work in dry condition, false detection of water.
59. CONDUCTIVITY
60. 60 AOS OVEN RANGE: INSTALLATION DRAIN SYSTEM : AIR BREAK
61. 61 AOS OVEN RANGE: INSTALLATION DRAIN SYSTEM INSTALLATION
62. 62