DIRECTORS: PROF. DR.G. LOHNERT, PROF. DR. E. LAURIEN, PROF. DR. M. SCHMIDT ADMINISTR.: DR. J. GÖBEL. GENERAL TASK. NUCLEAR TECHNOLOGY,THERMAL ENGINEERING, ENERGY SYSTEMS & ECONOMICS. SCIENTIFIC DIVISIONS. REACTOR SAFETY & ENVIRONMENT PROF. DR. G. LOHNERT
E N D
DIRECTORS: PROF. DR.G. LOHNERT, PROF. DR. E. LAURIEN, PROF. DR. M. SCHMIDT ADMINISTR.: DR. J. GÖBEL GENERAL TASK NUCLEAR TECHNOLOGY,THERMAL ENGINEERING, ENERGY SYSTEMS & ECONOMICS SCIENTIFIC DIVISIONS REACTOR SAFETY & ENVIRONMENT PROF. DR. G. LOHNERT (8 scientists) REACTOR PHYSICS DR. W. BERNNAT (4 scientists) ENERGY CONVERSION & THERMAL ENGG. PROF. DR. M. GROLL (21 scientists & technicians) HEATING, VENTILATION, AIR COND. PROF. DR. M. SCHMIDT (12 scientists & technicians) THERMOFLUIDDYNAMICS PROF. DR. E. LAURIEN (8 scientists) KNOWLEDGE ENGINEERING & NUMERICS PROF. DR. F. SCHMIDT (9 scientists & programmers) HIGH TEMPERATURE TECHNOLOGY DP. H.G. MAYER (10 scientists & technicians) 2003
Thermophysical Properties and Radiation Thermometry at IKE Staff.: Dipl.-Ing. R. Brandt, Prof. Dr. M. Groll, Dr. G. Neuer (consultant), Dipl.-Phys. E. Schreiber Thermal conductivity Comparative-Technique Temperature :0 °C to 950 °C, Sample-Ø: 50 mm or 25 mm Environment:: air, argon, vacuum Thermal conductivity Guarded Hot Plate -Technique Temperature :0 °C to 950 °C, Sample-Ø: 200 mm Environment:: air, argon, vacuum Thermal Diffusivity Modulated Leightbeam -Technique Temperature :250 °C to 1800 °C Sample-Ø: 8 mm Frequency variable, vacuum Specific Heat Capacity Differential-Scanning-CalorimeterTemperature :0 °C to 730 °C, Sample-Ø: 4 mm Environment:: argon Electric Resistivity Four Point Technique Temperature: 25 °C to 1600 °C Sample: 5 mm Ø, 100 mm length Measurements of melts in ceramic tube Spectral and total emissivity Radiation Comparison Technique Temperature: 600 °C to 2000 °C Sample: 15 mm Ø, 4 mm heigh Environment:: air, argon, vacuum Development and Calibration of Radiation Thermometers Linear Pyrometer (LP2/LP3) (Spectral And Multi - Wavelength), Laser - Absorption - Pyrometer Heat Pipe Blackbodies (350 K To 1350 K), Multi-Fixpoint Blackbodyradiator 2003
Dr. Guenther Neuer, IKE, Stuttgart. Leader WP4 Thermal Conductivity Head of the group Thermophysical Properties and Radiation Thermometry, and of the DKD- Calibration Laboratory (until 12/2002) Since 1/2003: Consultant at IKE Leader of the VDI/VDE-GMA expert group: Applied Radiation Thermometry Member of the German GEFTA expert group: Arbeitskreis Termophysik 2003