1 / 28

Thristor TYA-201

Thristor TYA-201. www.jumokorea.com. TYA-200 시리즈 소개. TYA-200 시리즈 소개 사양 및 결선도 Setup program LCD 표시 및 기호 설명 Features and technical data Benefits. 1. TYA-200 시리즈 소개. TYA 201 type 709061 ( 단상용 Thyristor) USB 를 통한 전원 및 통신으로 간편한 Set-up RS422/485 interface or PROFIBUS-DP 통신지원

zorina
Download Presentation

Thristor TYA-201

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Thristor TYA-201 www.jumokorea.com

  2. TYA-200 시리즈 소개 • TYA-200 시리즈 소개 • 사양 및 결선도 • Setup program • LCD 표시 및 기호 설명 • Features and technical data • Benefits Special Features TYA-201

  3. 1. TYA-200 시리즈 소개 • TYA 201 type 709061 (단상용 Thyristor) • USB를 통한 전원 및 통신으로 간편한 Set-up • RS422/485 interface or PROFIBUS-DP 통신지원 • phase control, burst-firing mode, and half-wave control 지원 • Soft start function with current limiting 지원 • Teach-in function을 통한 부하 문제발생등의 자체 진단 지원 • MoSi2 heating elements의 저항 모니터링 및 한계 설정 지원 • 간단한 부하 상태 점검 TYA-200 시리즈 구분 1. TYA 201 type 709061 (단상용) Single-phase Thyristor unit 2. TYA 202 type 709062 (삼상용) Three-phase Thyristor unit in three-phase current economy circuit Special Features TYA-201

  4. 2. 사양 및 결선도 TYA 201 Current range or size of device: 20 A / 32 A - 50 A / 75 A - 100 A / 150 A / 200 A - 250 A Power supply: 24- 500 V AC – 20 % / +15 % Additional power unit for control electronics is not necessary. Single-phase operation: phase / phase Single-phase operation Phase / N Special Features TYA-201

  5. 2. 사양 및 결선도 • 입력, 출력 설명 • Input 1 • 0(2) … 10 V • 0 … 5 V • Input 2 • 0(4) … 20 mA • 2 binary inputs • Firing-pulse inhibit due to floating contact • SSR-Input • Relay output 230 V / 3 A • Analog output0/4 … 20 mA, 0/2 … 10 V • Load connection #3 : 485 (+) #8 : 485 (-) #5 : ground Male 그림 Special Features TYA-201

  6. 3. Setup program • Set-up 프로그램의 특징 • 단순한 접근성 • 텍스트 표시로 터치 패드를 이용한 손쉬운 set-up 가능 • Connection via mini USB / self-supply • (USB를 통한 전원 공급 Set-up 가능) • Setup program • Hardware assistant • Startup (On-Line Graph를 화면에 표시) • Process values를 실시간 확인 가능 Special Features TYA-201

  7. 4. LCD 표시 및 기호 설명 Special Features TYA-201

  8. 5. Features and technical data • Load types subsidiary control • Resistive load with R warm / R cold – proportion 1:16 • Inductive loads (transformer load) • Infrared lamps (short, middle or long wave) • Voltage control U² , U • Current control I², I • Power control P • Without control Underlying control loop: principle Special Features TYA-201

  9. 6. Benefits • a). Easy setup • Pre-configuration via mini USB • Power supply via USB port on the computer • Display of all necessary measurement values on the device • Further measurement equipment is not necessary • Manual mode (control signal is not necessary) • b). Tunch in function • Teach in: The unit measures the current for the heating elements • If a heating element breaks the current will be reduced • Result: part load failure • The new „Teach In“ function is a self-learning function for automatic limit setting in the event of part-load failure recognition c). Dual energy management The standard Dual energy management“ coordinates the power output of several devices and avoids energy peaks. The function realizes a constant power distribution in the mains which results in lower energy costs. Special Features TYA-201

  10. critical R/ temp. 6. Benefits • d). R control - Resistance control and limiting • A too high surface temperature of the heating elements reduces • their durability, „R control„ function limits the temperature. • Resistance and surface temperature stick together. • R control limits to a definable • temperature by reducing the power. • The operating life is increased • and the operating costs are reduced. • e). A lot of intelligent security systems provides for an easy and • uncomplicated commissioning. • Rotating field recognition • Recognition of wiring errors • Power supply monitoring • Load control (part load and temperature) • High process security and continuousness Special Features TYA-201

  11. Set-up 설명 목차 1.기본적인 key 사용법 2. Device data 3. Power controller 3-1. basic setting 3-2. Soft start 3-3. Limitation, current/resistance 4. Analog inputs 5.Setpoint value configuration 5-1. Default values 5-2. Max. SCR output value/basic load 6.Monitoring 6-1. Limit value 6-2. Load 6-3. Main voltage drop 7.Binary inputs 7-1. Function 7-2. Control direction 8.Binary outputs 8-1. General 8-2. Binary signals 9.Actual value output 10.RS-422/RS-485 Special Features TYA-201

  12. 1.기본적인 key 사용법 Special Features TYA-201

  13. 2. Device data 온도 단위 설정 LCD 표시 시간 설정 (1분 경과후 Power 램프가 blink 표시) Manual mode 전환 암호 설정 Operator mode 전환 암호 설정 Configuration mode 전환 암호 설정 각 mode에 암호를 설정한 경우, 진입하려는 mode에 알맞은 설정된 암호를 입력하여 해당 mode에 진입합니다. 암호가 “0”인 경우는 암호 입력이 필요없이 진입됩니다. Special Features TYA-201

  14. 3. Power controller (basic setting) 3-1. basic setting 단상 제어 방식 설정 전력 제어 방식 Proportional 설정 동작 방식 Burst firing 설정 U2 Subordinated Control 아래 내용에 따른 Control 방식 설정 • U2 Control • - Kanthal-Super • - tungsten • - molybdenum • - platinum • quartz radiators • P control • A typical application of this type of subordinate control is for regulating heating elements which are subject to long-term aging combined with a temperaturedependent resistance, as is the case with silicon carbide elements 각 운정 방식에 적합한 Load의 예 각 운전 방식에 대한 간단한 설명 어떠한 Load type이 적합한 Operating mode 확인가능합니다. Special Features TYA-201

  15. 3. Power controller 3-2. Soft start Soft start 사용 (Teach-in mode 체크 제외) Soft start 유지 시간 설정 위상각이 변화하면서, soft start가 진행되어지는 그림입니다.. 출력이 30%라고 가정하면, 전진적으로 출력이 30%까지 증가하여 soft strart가 완료 됩니다... Special Features TYA-201

  16. 3. Power controller 3-3. Limitation, current/resistance Phase angle contorl시 사용되며, bust-firing mode에서는 soft start(phase angle control)에서만 적용됩니다. Load가 Silicon carbide elements일 경우 Subordinated Control을 P contol로 선정시 사용가능합니다. Special Features TYA-201

  17. 4. Analog inputs 전류 입력 설정 (1(-), 2(+)) 전압 입력 설정 (3(-), 4(+)) Special Features TYA-201

  18. 5.Setpoint value configuration 5-1. Default values 전류값 입력 설정 (0 ~ 20 mA) 에러 발생시 입력값 조정 설정 에러시 입력값 “0”으로 설정 Special Features TYA-201

  19. 5.Setpoint value configuration 5-2. Max. SCR output value/basic load U2 Subordinated Control 설정시 Max. Voltage 값 설정 U2 Subordinated Control 설정시 Min. Voltage 값 설정 Special Features TYA-201

  20. 6.Monitoring 6-1. Limit value 자체 온도 모니터링을 설정 Min alarm limit 값을 입력 Max alarm limit 값을 입력 Hysteresis limit 값을 입력 Special Features TYA-201

  21. 6.Monitoring 6-2. Load Only cascade control I, I2 or P, permitting measurement of the current. 직력(Over current) , 병렬 (Under current) 매뉴얼 6.1 Detection of load faults 확인요 TC = 약 1 로 가정하여 아래표의 값을 설정 현재의 전류를 측정, 저장하는 기간을 설정 수동, 전원입력시 자동, 1분에 한번씩 측정, 저장. 일반 Load 또는 적외선 방사체인지 설정 current percentage deviation Special Features TYA-201

  22. 6.Monitoring 6-3. Main voltage drop 메인 전원 전압 강하시 릴레이 출력 기능 설정 Special Features TYA-201

  23. 7.Binary inputs 7-1. Function 제어가 Logic input 시 활성화 Logic input1 입력시 아래 20 A 설정 사용하여 알람 출력 Logic input1 입력시 작용하는 Limit 값 설정 Keyboard lock 설정 LCD 화면 표시 사용 7-2. Control direction 부하에 대한 전력 출력 제한이 “Open” 또는 “Close” 상태인지 설정 (8,7(GND)) 현재의 “Open load ON”은 접점이 Open 상태에서 전력을 부하측에 공급됩니다. Binary input 1이 Open 상태에서 Keyboard lock, Lcd가 동작 안함 Binary input 2이 Open 상태에서 Keyboard lock, Lcd가 동작 안함 Special Features TYA-201

  24. 8.Binary outputs 8-1. General 릴레이 또는 Optocoupler 사용 접점 방식 설정 Special Features TYA-201

  25. 8.Binary outputs 8-2. Binary signals Min alarm limit value 이하시 작동 Max alarm limit value 이상시 작동 부하 저항값 설정보다 높을때 동작 내부 휴즈 손상 전력 사용 증가로 온도 상승할때 동작 자체 온도가 100도 보다 높을때 동작 메인 전압이 불안정(10%이상)할때 동작 Special Features TYA-201

  26. 9.Actual value output 출력 방식 설정 출력 대상 설정 출력 Low 값 입력 출력 Max값 입력 Value to be output Signal type of actual value output Special Features TYA-201

  27. 10.RS-422/RS-485 통신 속도 설정 전송 방식 설정 Address 설정 (최대 31개) 응답 최소 시간 설정 Special Features TYA-201

  28. TYA- 200발표를 마칩니다 Special Features LOGOSCREEN nt

More Related