1 / 12

Status of Geant4 (svd + pxd)

Status of Geant4 (svd + pxd). Kibayashi May 30, 2007 For SVD Soft Meeting. What we have now Modules. Recap (already existing g4superb- *** ) kernel : to control the detectors, define physics & particles, generator interface, event action io : input/output managers, supports PANTHER

agatha
Download Presentation

Status of Geant4 (svd + pxd)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Status of Geant4(svd + pxd) Kibayashi May 30, 2007 For SVD Soft Meeting

  2. What we have nowModules • Recap (already existing g4superb-***) • kernel : to control the detectors, define physics & particles, generator interface, event action • io : input/output managers, supports PANTHER • svd, cdc, top, rich, ecl(module exists but doesn’t work?), klm, kekb, solenoid Need to revisit and summarize what’s done & what’s to be done (by next March) in each sub-detector. • Added • pxd for pixel detector w/ beam pipe • Ir reserved for IR region (to be combined with kekb?) • Report here mainly on svd and pxd… • Your wisdom and inputs highly appreciated!

  3. Geometry : Mother Volume y Red lines indicate Mother Volume, reserved volume for each sub-detectors (units in mm) aBoth SVD and PXD sit w/i their Mother Volumes x (-500,150) (700,150) (-500,80) (-90,12) (130,12) (700,80)

  4. PXD : geometry(b20070528) Central super-flat beam pipe (Be) (7x1x25)x2 Vacuum inside beam pipe (5x0.5x25)x2 2 Silicon PXD detectors (Si) (7x0.15x25)x2 Placed upper & lower of the SFBP 350x2 beam trapezoid(fwd) (Be) (50x50)x2 (7x1.15)x2 beam trapezoid (bwd) 500x2 *all units in mm (50x50)x2 ToDo: beam trapezoid is currently solid Be, need vacuum inside…

  5. PXD : Hits Pixel size = 20 mm x 20 mm 1 349 Cell ID x 0 … Upper pxd = Sensor 0 Cell ID z 0 … 2499 2499 … 0 Cell ID z Lower pxd = Sensor 1 Cell ID x 0 … 349 y • - Local position/global position determined by (in_pos+out_pos)/2. • Hit cell ID determined by the local position (x, z). x z

  6. SVD : geometryby Tajima-san 2nd layer 1st layer - Same Geometry as in LoI. - note: one DSSD/ladder 3rd layer 4th layer 5th layer 6th layer

  7. PXD : panther table • DATPXD_TRUEHIT • sensor : ID upper(0) or lower(1) • track : ID • dir : outwards(0) or inwards(1) • elec : no. of electrons = total energy deposit/3.6 eV • gpos(3) : global position • lpos(3) : local position g needs smearing by Gaussian • cell(2) : cell ID in (x, z)

  8. SVD : GeometryB4SVD_Geometry.dat - all units in mm, rad - dssd thickness = 0.3 for all DSSDs - peripheral means outside of sensitive region, width + peripheral=> width of the DSSD - shift: % of width off from x=0 - phi_offset = % of phi shifts from a to b Slanted DSSDs trapezoid shapes. Length/2 Width/2 Swidth/2

  9. SVD : panther tableby KHara-san • REDSVD3_CLUSTER • Sensor : sensor (DSSD) ID • Type : p or n (1 or 0) • Width : currently 0 • Elec : no. of electrons = total Edep/3.6 eV • Eren : currently 0 • Pos : local cluster position smeared by incident angle dependent sigma (obsolete, from old Kawasaki-san’s beam test result) • Erpos : error on position • DATSVD3_TRUEHIT • Sensor : DSSD number • Track : track ID number • Dir : direction of the track, outward (0) or inward (1) • Elec : no. of electrons = total Edep/3.6 eV • Gpos(3) : global truehit position • Lpos(3) : local truehit position • Hep :

  10. Summary • Done • Added g4superb-pxd • g4superb-cdc and trasan implemented by Katayama-san • Helix parameters are available • ToDo Next • Implement TRAK • Geant4 • Start w/ current SVD geometry, 4 layers w/o slanted DSSD, assume 1DSSD/ladder • TRAK • Readout from local position not lsa • Cross-check with TRAKERR

  11. Test SVD2 geometry (Units in mm.)

More Related